A durable load bearing muscle to prosthetic coupling

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT; FIBERS; PROSTHETICS; TISSUE;

EID: 0037880507     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.MAT.0000065369.46216.9C     Document Type: Article
Times cited : (8)

References (29)
  • 1
    • 0023330361 scopus 로고
    • Skeletal muscle as the potential power source for a cardiovascular pump: Assessment in vivo
    • Acker MA, Hammond RL, Mannion JD, Salmons S, Stephenson LW: Skeletal muscle as the potential power source for a cardiovascular pump: Assessment in vivo. Science 236: 324-327, 1987.
    • (1987) Science , vol.236 , pp. 324-327
    • Acker, M.A.1    Hammond, R.L.2    Mannion, J.D.3    Salmons, S.4    Stephenson, L.W.5
  • 2
    • 0023816317 scopus 로고
    • Maximal blood flow and power output of dog muscle in situ
    • Stainsby WN, Andrew EM: Maximal blood flow and power output of dog muscle in situ. Med Sci Sports Exerc 20(Suppl.): 109-112, 1988.
    • (1988) Med Sci Sports Exerc , vol.20 , Issue.SUPPL. , pp. 109-112
    • Stainsby, W.N.1    Andrew, E.M.2
  • 3
    • 0029872525 scopus 로고    scopus 로고
    • Cardiomyoplasty: Degeneration of the assisting skeletal muscle
    • Ianuzzo CD, Ianuzzo SE, Carson N, et al: Cardiomyoplasty: Degeneration of the assisting skeletal muscle. J Appl Physiol 80: 1205-1213, 1996.
    • (1996) J Appl Physiol , vol.80 , pp. 1205-1213
    • Ianuzzo, C.D.1    Ianuzzo, S.E.2    Carson, N.3
  • 4
    • 0027937996 scopus 로고
    • Ergometric studies of untrained skeletal muscle demonstrate feasibility of muscle-powered cardiac assistance
    • Trumble DR, Magovern JA: Ergometric studies of untrained skeletal muscle demonstrate feasibility of muscle-powered cardiac assistance. J Appl Physiol 77: 2036-2041, 1994.
    • (1994) J Appl Physiol , vol.77 , pp. 2036-2041
    • Trumble, D.R.1    Magovern, J.A.2
  • 5
    • 0025736827 scopus 로고
    • Comparison of canine skeletal muscle power from twitches and tetanic contractions in untrained muscle: A preliminary report
    • Tacker WA, Geddes LA, Janas W, Babbs CF, Badylak SF: Comparison of canine skeletal muscle power from twitches and tetanic contractions in untrained muscle: A preliminary report. J Card Surg 6: 245-251, 1991.
    • (1991) J Card Surg , vol.6 , pp. 245-251
    • Tacker, W.A.1    Geddes, L.A.2    Janas, W.3    Babbs, C.F.4    Badylak, S.F.5
  • 6
    • 0022751362 scopus 로고
    • Transmural blood flow of multi-layered latissimus dorsi skeletal muscle ventricles during circulatory assistance
    • Mannion JD, Belchik MA, Acker M, et al: Transmural blood flow of multi-layered latissimus dorsi skeletal muscle ventricles during circulatory assistance. Trans Am Soc Artif Intern Org 32: 454-459, 1986.
    • (1986) Trans Am Soc Artif Intern Org , vol.32 , pp. 454-459
    • Mannion, J.D.1    Belchik, M.A.2    Acker, M.3
  • 7
    • 0026795696 scopus 로고
    • Cardiac assistance from skeletal muscle: A critical appraisal of the various approaches
    • Salmons S, Jarvis JC: Cardiac assistance from skeletal muscle: A critical appraisal of the various approaches. Br Heart J 68: 333-338, 1992.
    • (1992) Br Heart J , vol.68 , pp. 333-338
    • Salmons, S.1    Jarvis, J.C.2
  • 8
    • 0038034890 scopus 로고
    • Muscle mass and design requirements for cardiac assist systems
    • Chiu RC-J (ed), Mt. Kisco, NY: Futura
    • Khalafala AS: Muscle mass and design requirements for cardiac assist systems, in Chiu RC-J (ed), Biomechanical Cardiac Assist. Mt. Kisco, NY: Futura, 1986, pp. 151-178.
    • (1986) Biomechanical Cardiac Assist , pp. 151-178
    • Khalafala, A.S.1
  • 9
    • 0009281630 scopus 로고
    • Skeletal muscle for artificial heart drive
    • Chiu RC-J (ed), Mt Kisco, NY: Futura
    • Ugolini F: Skeletal muscle for artificial heart drive, in Chiu RC-J (ed), Biomechanical Cardiac Assist. Mt Kisco, NY: Futura, 1986, pp. 193-210.
    • (1986) Biomechanical Cardiac Assist , pp. 193-210
    • Ugolini, F.1
  • 10
    • 0023761813 scopus 로고
    • Skeletal muscle ventricles as a potential right heart assist or substitute
    • Anderson WA, Andersen JS, Bridges CR, et al. Skeletal muscle ventricles as a potential right heart assist or substitute. Trans Am Soc Artif Intern Org 34: 241-246, 1988.
    • (1988) Trans Am Soc Artif Intern Org , vol.34 , pp. 241-246
    • Anderson, W.A.1    Andersen, J.S.2    Bridges, C.R.3
  • 12
    • 0026925795 scopus 로고
    • A new skeletal muscle linear-pull energy converter as a power source for prosthetic circulatory support devices
    • Farrar DJ, Hill JD: A new skeletal muscle linear-pull energy converter as a power source for prosthetic circulatory support devices. J Heart Lung Transplant 11 (Suppl.): 341-350, 1992.
    • (1992) J Heart Lung Transplant , vol.11 , Issue.SUPPL. , pp. 341-350
    • Farrar, D.J.1    Hill, J.D.2
  • 13
    • 0031239730 scopus 로고    scopus 로고
    • Power generation from four skeletal muscle configurations. Design implications for a muscle powered cardiac assist device
    • Badhwar V, Gadhwar RK, Oh J-H, Chiu RC-J: Power generation from four skeletal muscle configurations. Design implications for a muscle powered cardiac assist device. ASAIO J 43: 651-657, 1997.
    • (1997) ASAIO J , vol.43 , pp. 651-657
    • Badhwar, V.1    Gadhwar, R.K.2    Oh, J.-H.3    Chiu, R.C.-J.4
  • 14
    • 0342345988 scopus 로고
    • Contractility, with special reference to skeletal muscle
    • Mountcastle VB (ed), St. Louis: Mosby
    • Dowben RM: Contractility, with special reference to skeletal muscle, in Mountcastle VB (ed), Medical Physiology, 14th ed. St. Louis: Mosby, 1980, pp. 82-119.
    • (1980) Medical Physiology, 14th Ed. , pp. 82-119
    • Dowben, R.M.1
  • 15
    • 0013771834 scopus 로고
    • A small ventricle-type pump for prolonged perfusions: Construction and initial studies including attempts to power a pump biologically with skeletal muscle
    • Kusserow BK, Clapp JF: A small ventricle-type pump for prolonged perfusions: Construction and initial studies including attempts to power a pump biologically with skeletal muscle. Trans Am Soc Artif Intern Org 8: 74, 1967.
    • (1967) Trans Am Soc Artif Intern Org , vol.8 , pp. 74
    • Kusserow, B.K.1    Clapp, J.F.2
  • 17
    • 0017662093 scopus 로고
    • Long-term stimulation of a diaphragm muscle pouch
    • Von Recum A, Stulc J, Hamada O: Long-term stimulation of a diaphragm muscle pouch. J Surg Res 23: 422, 1977.
    • (1977) J Surg Res , vol.23 , pp. 422
    • Von Recum, A.1    Stulc, J.2    Hamada, O.3
  • 18
    • 0038373176 scopus 로고
    • The chronically stimulated psoas muscle as an energy source for artificial organs: An experimental study in sheep
    • Chiu RC-J (ed), Mt Kisco, NY: Futura
    • Frey M, Thoma H, Gruber H, Stohr H, Havel M: The chronically stimulated psoas muscle as an energy source for artificial organs: An experimental study in sheep, in Chiu RC-J (ed), Biomechanical Cardiac Assist. Mt Kisco, NY: Futura, 1986, pp. 179-191.
    • (1986) Biomechanical Cardiac Assist , pp. 179-191
    • Frey, M.1    Thoma, H.2    Gruber, H.3    Stohr, H.4    Havel, M.5
  • 19
    • 0028468537 scopus 로고
    • In vivo measurements of skeletal muscle in a linear configuration powering a hydraulically actuated VAD
    • Farrar DJ, Reichenbach SH, Hill JD: In vivo measurements of skeletal muscle in a linear configuration powering a hydraulically actuated VAD. ASAIO J 40: M309-M313, 1995.
    • (1995) ASAIO J , vol.40
    • Farrar, D.J.1    Reichenbach, S.H.2    Hill, J.D.3
  • 20
    • 0028465472 scopus 로고
    • Characterization and work optimization of skeletal muscle as a VAD power source
    • Reichenbach SH, Farrar DJ: Characterization and work optimization of skeletal muscle as a VAD power source. ASAIO J 40: M359-M364, 1995.
    • (1995) ASAIO J , vol.40
    • Reichenbach, S.H.1    Farrar, D.J.2
  • 21
    • 0038711456 scopus 로고    scopus 로고
    • Muscle-powered blood pump: Design and initial test results
    • Abstract
    • Trumble DR, Magovern JA: Muscle-powered blood pump: Design and initial test results. (Abstract) ASAIO J 44: 38, 1998.
    • (1998) ASAIO J , vol.44 , pp. 38
    • Trumble, D.R.1    Magovern, J.A.2
  • 22
    • 0036266376 scopus 로고    scopus 로고
    • Chronic implantation of fibrous artificial tendon demonstrates stability of muscle fixation to metallic motor prosthesis
    • Trumble, DR, Melvin DB, Magovern JA: Chronic implantation of fibrous artificial tendon demonstrates stability of muscle fixation to metallic motor prosthesis. ASAIO J 48: 62-70, 2002.
    • (2002) ASAIO J , vol.48 , pp. 62-70
    • Trumble, D.R.1    Melvin, D.B.2    Magovern, J.A.3
  • 23
    • 0014244037 scopus 로고
    • Some physical factors affecting the acceptance of synthetic materials as tissue implants
    • Davila JC, Lautsch EV, Palmer TE: Some physical factors affecting the acceptance of synthetic materials as tissue implants. Ann N Y Acad Sci 146: 138-147, 1968.
    • (1968) Ann N Y Acad Sci , vol.146 , pp. 138-147
    • Davila, J.C.1    Lautsch, E.V.2    Palmer, T.E.3
  • 24
    • 0015795856 scopus 로고
    • Polymeric materials: Current status of biocompatibility
    • Bruck SD: Polymeric materials: Current status of biocompatibility. Biomater Med Devices Artif Organs 1: 79-98, 1973.
    • (1973) Biomater Med Devices Artif Organs , vol.1 , pp. 79-98
    • Bruck, S.D.1
  • 25
    • 0031238956 scopus 로고    scopus 로고
    • Coupling of skeletal muscle to a prosthesis for circulatory support
    • Melvin DB, Glos DL, Abiog MC, Litsky AS: Coupling of skeletal muscle to a prosthesis for circulatory support. ASAIO J 43: M434-M441, 1997.
    • (1997) ASAIO J , vol.43
    • Melvin, D.B.1    Glos, D.L.2    Abiog, M.C.3    Litsky, A.S.4
  • 26
    • 0025321888 scopus 로고
    • Comparative anatomy and histochemistry of human and canine latissimus dorsi muscle
    • Sola OM, Haines LC, Kakulas BA: Comparative anatomy and histochemistry of human and canine latissimus dorsi muscle. J Heart Lung Transplant 9: 151-159, 1990.
    • (1990) J Heart Lung Transplant , vol.9 , pp. 151-159
    • Sola, O.M.1    Haines, L.C.2    Kakulas, B.A.3
  • 27
    • 0035103163 scopus 로고    scopus 로고
    • The totally implantable Novacor left ventricular assist system
    • Robbins RC, Kown MH, Portner PM, Oyer PE: The totally implantable Novacor left ventricular assist system. Ann Thorac Surg 71(Suppl.): 162-165, 2001.
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL. , pp. 162-165
    • Robbins, R.C.1    Kown, M.H.2    Portner, P.M.3    Oyer, P.E.4
  • 28
    • 0001326133 scopus 로고    scopus 로고
    • Multicenter clinical evaluation of the Heartmate vented electric left ventricular assist system in patients awaiting heart transplantation
    • Frazier OH, Rose EA, Oz MC: Multicenter clinical evaluation of the Heartmate vented electric left ventricular assist system in patients awaiting heart transplantation. J Heart Lung Transplant 20: 201-202, 2001.
    • (2001) J Heart Lung Transplant , vol.20 , pp. 201-202
    • Frazier, O.H.1    Rose, E.A.2    Oz, M.C.3
  • 29
    • 0035104265 scopus 로고    scopus 로고
    • A versatile intracorporeal ventricular assist device based on the Thoratec VAD system
    • Reichenbach SH, Farrar DJ, Hill JD: A versatile intracorporeal ventricular assist device based on the Thoratec VAD system. Ann Thorac Surg 71(Suppl.): 171-175, 2001.
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL. , pp. 171-175
    • Reichenbach, S.H.1    Farrar, D.J.2    Hill, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.