메뉴 건너뛰기




Volumn 82, Issue 1, 1999, Pages 11-13

Conversion factor for comparison of data from Humphrey and Medmont automated perimeters

Author keywords

Humphrey Field Analyser; Medmont M600 automated perimeter; Perimetry; Weber fraction

Indexed keywords


EID: 0037878434     PISSN: 08164622     EISSN: 14440938     Source Type: Journal    
DOI: 10.1111/j.1444-0938.1999.tb06779.x     Document Type: Article
Times cited : (5)

References (10)
  • 1
    • 0025368583 scopus 로고
    • The Opticom M-600: A new LED automated perimeter
    • Vingrys AJ, Helfrich KA. The Opticom M-600: a new LED automated perimeter. Clin Exp Optom 1990; 73: 3–17.
    • (1990) Clin Exp Optom , vol.73 , pp. 3-17
    • Vingrys, A.J.1    Helfrich, K.A.2
  • 3
    • 0023616593 scopus 로고
    • The effect of refractive error on automated global analysis program G-1
    • Goldstick BJ, Weinreb RN. The effect of refractive error on automated global analysis program G-1. Amer J Ophthalmol 1987; 104: 229–232.
    • (1987) Amer J Ophthalmol , vol.104 , pp. 229-232
    • Goldstick, B.J.1    Weinreb, R.N.2
  • 4
    • 0024820915 scopus 로고
    • The influence of decreased retinal illumination on automated perimetric threshold measurements
    • Heuer DK, Anderson DR, Feuer WJ, Gressel MG. The influence of decreased retinal illumination on automated perimetric threshold measurements. Amer J Ophthalmol 1989; 108: 643–650.
    • (1989) Amer J Ophthalmol , vol.108 , pp. 643-650
    • Heuer, D.K.1    Anderson, D.R.2    Feuer, W.J.3    Gressel, M.G.4
  • 5
    • 0023675164 scopus 로고
    • Factors affecting the normal perimetric profile derived by automated static perimetry. I. Pupil size
    • Wood JM, Wild JM, Bullimore MA, Gilmartin B. Factors affecting the normal perimetric profile derived by automated static perimetry. I. Pupil size. Ophthal Physiol Opt 1988; 8: 26–31.
    • (1988) Ophthal Physiol Opt , vol.8 , pp. 26-31
    • Wood, J.M.1    Wild, J.M.2    Bullimore, M.A.3    Gilmartin, B.4
  • 6
    • 0013688147 scopus 로고    scopus 로고
    • Temporal modulation thresholds isolate mechanisms with different adaptational and spatial properties
    • Washington DC, Optical Society of America
    • Vingrys AJ, Demirel S. Temporal modulation thresholds isolate mechanisms with different adaptational and spatial properties. In: Vision Science and its Applications, Technical Digest 98-1. Washington DC: Optical Society of America. 1998: 78–81.
    • (1998) Vision Science and its Applications, Technical Digest 98-1 , pp. 78-81
    • Vingrys, A.J.1    Demirel, S.2
  • 7
    • 0018733841 scopus 로고
    • Problems related to the design of automated perimeters
    • Fankhauser F. Problems related to the design of automated perimeters. Doc Ophthalmol 1979; 47: 89–138.
    • (1979) Doc Ophthalmol , vol.47 , pp. 89-138
    • Fankhauser, F.1
  • 8
    • 0001924355 scopus 로고
    • The Humphrey Field Analyser, construction and concepts
    • Heijl A. The Humphrey Field Analyser, construction and concepts. Doc Ophthalmol Proc Ser 1985; 42: 77–84.
    • (1985) Doc Ophthalmol Proc Ser , vol.42 , pp. 77-84
    • Heijl, A.1
  • 9
    • 10944247511 scopus 로고
    • Static automated perimetry: Background luminance and global visual field indices in the quantification of normal, suspect and glaucomatous visual fields
    • Starita RJ, Fellman RL, Lynn JR. Static automated perimetry: background luminance and global visual field indices in the quantification of normal, suspect and glaucomatous visual fields. Invest Ophthalmol Vis Sci 1987; 28 (Suppl): 269.
    • (1987) Invest Ophthalmol Vis Sci , vol.28 , pp. 269
    • Starita, R.J.1    Fellman, R.L.2    Lynn, J.R.3
  • 10
    • 9444297740 scopus 로고
    • Effect of increased background luminance on static threshold perimetry
    • Paige GD. Effect of increased background luminance on static threshold perimetry. Invest Ophthalmol Vis Sci 1985; 26 (Suppl): 226.
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , pp. 226
    • Paige, G.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.