메뉴 건너뛰기




Volumn 1, Issue , 2003, Pages 471-476

Physiological Control of Blood Pumps Without Implantable Sensors

Author keywords

Model based estimation; Physiological control; Rotary blood pumps; Ventricular assist device

Indexed keywords

BIOMEDICAL EQUIPMENT; BLOOD; COMPUTER SIMULATION; KALMAN FILTERING; PHYSIOLOGY;

EID: 0037838265     PISSN: 07431619     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (13)

References (10)
  • 2
    • 0034841434 scopus 로고    scopus 로고
    • Modeling of the human circulatory system with an axial flow ventricular assist device
    • G. A. Giridharan and M. Skliar. Modeling of the human circulatory system with an axial flow ventricular assist device. In Proceedings of the American Control Conference, volume 5, pages 3801-3806, 2001.
    • (2001) Proceedings of the American Control Conference , vol.5 , pp. 3801-3806
    • Giridharan, G.A.1    Skliar, M.2
  • 3
    • 0038514697 scopus 로고    scopus 로고
    • Controller design for ventricular assist devices using nonlinear hybrid model for the human circulatory system
    • J. B. Rawlings, B. A. Ogunnaike, and J. W. Eaton, editors, CACHE, American Institute of Chemical Engineers, 2002 Proceedings of Chemical Process Control-6, Tucson Arizona, January
    • G. A. Giridharan and M. Skliar. Controller design for ventricular assist devices using nonlinear hybrid model for the human circulatory system. In J. B. Rawlings, B. A. Ogunnaike, and J. W. Eaton, editors, Chemical Process Control - VI: Assessment and New Directions for Research, volume 98:326 of AIChE Symposium Series, pages 379-383. CACHE, American Institute of Chemical Engineers, 2002. Proceedings of Chemical Process Control-6, Tucson Arizona, January 2001.
    • (2001) Chemical Process Control - VI: Assessment and New Directions for Research, Volume 98:326 of AIChE Symposium Series , vol.98 , Issue.326 , pp. 379-383
    • Giridharan, G.A.1    Skliar, M.2
  • 4
    • 0036428619 scopus 로고    scopus 로고
    • Nonlinear controller for ventricular assist devices
    • G. A. Giridharan and M. Skliar. Nonlinear controller for ventricular assist devices. Artificial Organs, 26:980-984, 2002.
    • (2002) Artificial Organs , vol.26 , pp. 980-984
    • Giridharan, G.A.1    Skliar, M.2
  • 5
    • 0037898308 scopus 로고    scopus 로고
    • Control strategy for maintaining physiological perfusion with implantable rotary blood pumps
    • accepted
    • G. A. Giridharan and M. Skliar. Control strategy for maintaining physiological perfusion with implantable rotary blood pumps. Artificial Organs, 27:accepted, 2003.
    • (2003) Artificial Organs , vol.27
    • Giridharan, G.A.1    Skliar, M.2
  • 6
    • 0036558955 scopus 로고    scopus 로고
    • Modeling and control of a brushless dc axial flow ventricular assist device
    • G. A. Giridharan, M. Skliar, D. B. Olsen, and G. Pantalos. Modeling and control of a brushless dc axial flow ventricular assist device. ASAIO, 48:272-289, 2002.
    • (2002) ASAIO , vol.48 , pp. 272-289
    • Giridharan, G.A.1    Skliar, M.2    Olsen, D.B.3    Pantalos, G.4
  • 9
    • 0024627812 scopus 로고
    • Modeling, simulation and analysis of permanent magnet motor drives, part 2: The brushless dc motor drives
    • P. Pillay and R. Krishnan. Modeling, simulation and analysis of permanent magnet motor drives, part 2: The brushless dc motor drives. IEEE Transactions on Industrial Applications, 25:263-273, 1989.
    • (1989) IEEE Transactions on Industrial Applications , vol.25 , pp. 263-273
    • Pillay, P.1    Krishnan, R.2
  • 10
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • A. Savitzky and M. J. E. Golay, Smoothing and differentiation of data by simplified least squares procedures. Analytical Chemistry, 36:1627-1639, 1964.
    • (1964) Analytical Chemistry , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.