메뉴 건너뛰기




Volumn 11, Issue 1, 2003, Pages 58-62

Fate of stentless bioprostheses on right side of the heart

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ARTIFICIAL HEART PACEMAKER; BACTERIAL ENDOCARDITIS; BIOMEDICAL TECHNOLOGY ASSESSMENT; BIOPROSTHESIS; BLEEDING; CHILD; CLINICAL ARTICLE; CONGENITAL HEART MALFORMATION; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; ENDOCARDITIS; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE OUTFLOW TRACT OBSTRUCTION; HEART VALVE; HEMISPHERIC DOMINANCE; HUMAN; INTUBATION; LIFESTYLE; MALE; MORTALITY; PERICARDIAL EFFUSION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRESSURE GRADIENT; REOPERATION; STATISTICAL ANALYSIS; STENOSIS; SURGICAL TECHNIQUE; TREATMENT OUTCOME; TRICUSPID VALVE REGURGITATION;

EID: 0037830085     PISSN: 02184923     EISSN: None     Source Type: Journal    
DOI: 10.1177/021849230301100114     Document Type: Article
Times cited : (17)

References (13)
  • 1
    • 0025899094 scopus 로고
    • Extracardiac valved conduits in pulmonary circuit
    • Sano S, Karl TR, Mee RB. Extracardiac valved conduits in pulmonary circuit. Ann Thorac Surg 1991;52:285-90.
    • (1991) Ann Thorac Surg , vol.52 , pp. 285-290
    • Sano, S.1    Karl, T.R.2    Mee, R.B.3
  • 2
    • 0028902792 scopus 로고
    • Stentless porcine aortic root: Valve of choice for the elderly patient with small aortic root?
    • Sintek CF, Fletcher AD, Khonsari S. Stentless porcine aortic root: Valve of choice for the elderly patient with small aortic root? J Thorac Cardiovasc Surg 1995;109:871-6.
    • (1995) J Thorac Cardiovasc Surg , vol.109 , pp. 871-876
    • Sintek, C.F.1    Fletcher, A.D.2    Khonsari, S.3
  • 3
    • 0032720385 scopus 로고    scopus 로고
    • Aortic valve replacement: Is the stentless xenograft an alternative to the homograft? Midterm results
    • Gross G, Harringer W, Beran H, Mair R, Sihorsch K, Hofmann R, et al. Aortic valve replacement: Is the stentless xenograft an alternative to the homograft? Midterm results. Ann Thorac Surg 1999;68:919-24.
    • (1999) Ann Thorac Surg , vol.68 , pp. 919-924
    • Gross, G.1    Harringer, W.2    Beran, H.3    Mair, R.4    Sihorsch, K.5    Hofmann, R.6
  • 4
    • 0034212537 scopus 로고    scopus 로고
    • Reconstruction of the RVOT with valved biological conduits: 25 years experience with allografts and xenografts
    • Homann M, Haehnel JC, Mendler N, Paek SU, Holper K, Meisner H, et al. Reconstruction of the RVOT with valved biological conduits: 25 years experience with allografts and xenografts. Eur J Cardio-thorac Surg 2000;17:624-30.
    • (2000) Eur J Cardio-thorac Surg , vol.17 , pp. 624-630
    • Homann, M.1    Haehnel, J.C.2    Mendler, N.3    Paek, S.U.4    Holper, K.5    Meisner, H.6
  • 5
    • 0035013022 scopus 로고    scopus 로고
    • Performance of allografts and xenografts for right ventricular outflow tract reconstruction
    • Lange R, Weipert J, Homann M, Mendler N, Paek SUI, Holper K, et al. Performance of allografts and xenografts for right ventricular outflow tract reconstruction. Ann Thorac Surg 2001;71:365-7.
    • (2001) Ann Thorac Surg , vol.71 , pp. 365-367
    • Lange, R.1    Weipert, J.2    Homann, M.3    Mendler, N.4    Paek, S.U.I.5    Holper, K.6
  • 10
    • 0033202010 scopus 로고    scopus 로고
    • Comparison of results using "freestyle" stentless porcine aortic root bioprosthesis with cryopreserved aortic allograft
    • Kon ND, Cordell AR, Adair SM, Kitzman DW. Comparison of results using "freestyle" stentless porcine aortic root bioprosthesis with cryopreserved aortic allograft. Semin Thorac Cardiovasc Surg 1999;11:69-73.
    • (1999) Semin Thorac Cardiovasc Surg , vol.11 , pp. 69-73
    • Kon, N.D.1    Cordell, A.R.2    Adair, S.M.3    Kitzman, D.W.4
  • 11
    • 0033201756 scopus 로고    scopus 로고
    • Pathologic analysis of nonstented Freestyle aortic root bioprosthesis
    • Fyfe BS, Schoen FJ. Pathologic analysis of nonstented Freestyle aortic root bioprosthesis. Semin Thorac Cardiovasc Surg 1999;11:151-6.
    • (1999) Semin Thorac Cardiovasc Surg , vol.11 , pp. 151-156
    • Fyfe, B.S.1    Schoen, F.J.2
  • 12
    • 0033965913 scopus 로고    scopus 로고
    • A quantitative study of calcium deposition in the aortic wall following Medtronic Freestyle compared with homograft aortic root replacement. A prospective randomized trial
    • Melina G, Rubens MB, Birks EJ, Bizzarri F, Khaghani A, Yacoup MH. A quantitative study of calcium deposition in the aortic wall following Medtronic Freestyle compared with homograft aortic root replacement. A prospective randomized trial. J Heart Valve Dis 2000;9:97-103.
    • (2000) J Heart Valve Dis , vol.9 , pp. 97-103
    • Melina, G.1    Rubens, M.B.2    Birks, E.J.3    Bizzarri, F.4    Khaghani, A.5    Yacoup, M.H.6
  • 13
    • 0028417239 scopus 로고
    • The pulmonary valve: Is it mechanically suitable for use as an aortic valve replacement?
    • David H, Boughner DR, Vesely I, Gerosa G. The pulmonary valve: Is it mechanically suitable for use as an aortic valve replacement? ASAIO J 1994;40:206-12.
    • (1994) ASAIO J , vol.40 , pp. 206-212
    • David, H.1    Boughner, D.R.2    Vesely, I.3    Gerosa, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.