메뉴 건너뛰기




Volumn 48, Issue 13, 2003, Pages 1895-1905

The value of radiochromic film dosimetry around air cavities: Experimental results and Monte Carlo simulations

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; MONTE CARLO METHODS; POLYSTYRENES; RADIOTHERAPY; TISSUE;

EID: 0037769053     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/48/13/303     Document Type: Article
Times cited : (15)

References (13)
  • 1
  • 3
    • 0032860849 scopus 로고    scopus 로고
    • Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams
    • De Vlamynck K, Palmans H, Verhaegen F, De Wagter C, De Neve W and Thierens H 1999 Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams Med. Phys. 26 1874-82
    • (1999) Med. Phys. , vol.26 , pp. 1874-1882
    • De Vlamynck, K.1    Palmans, H.2    Verhaegen, F.3    De Wagter, C.4    De Neve, W.5    Thierens, H.6
  • 4
    • 0033866920 scopus 로고    scopus 로고
    • Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    • Francescon P, Cavedon C, Reccanello S and Cora S 2000 Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM Med. Phys. 27 1579-87
    • (2000) Med. Phys. , vol.27 , pp. 1579-1587
    • Francescon, P.1    Cavedon, C.2    Reccanello, S.3    Cora, S.4
  • 7
    • 0035996450 scopus 로고    scopus 로고
    • Underdosage of the upper-airway mucosa for small fields as used in IMRT: A comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations
    • Martens C, Reynaert N, De Wagter C, Nilsson P, Coghe M, Palmans H, Thierens H and De Neve W 2002 Underdosage of the upper-airway mucosa for small fields as used in IMRT: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations Med. Phys. 29 1528-35
    • (2002) Med. Phys. , vol.29 , pp. 1528-1535
    • Martens, C.1    Reynaert, N.2    De Wagter, C.3    Nilsson, P.4    Coghe, M.5    Palmans, H.6    Thierens, H.7    De Neve, W.8
  • 8
    • 0031807510 scopus 로고    scopus 로고
    • Characteristics of a commercially available film digitizer and their significance for film dosimetry
    • Mersseman B and De Wagter C 1998 Characteristics of a commercially available film digitizer and their significance for film dosimetry Phys. Med. Biol. 43 1803-12
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1803-1812
    • Mersseman, B.1    De Wagter, C.2
  • 11