메뉴 건너뛰기




Volumn , Issue , 2003, Pages 141-147

Retrofilling aging transformers with natural ester based dielectric coolant for safety and life extension

Author keywords

[No Author keywords available]

Indexed keywords

AGING OF MATERIALS; COOLANTS; DATA ACQUISITION; ELECTRIC INSULATION; ELECTRIC TRANSFORMERS; RETROFITTING;

EID: 0037712091     PISSN: 07314906     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (40)

References (7)
  • 1
    • 0032643320 scopus 로고    scopus 로고
    • Fire resistant natural ester dielectric fluid and novel insulation system for its use
    • Apr. 12 -16
    • McShane, C.P., Gauger, G.A., Luksich, J.; "Fire Resistant Natural Ester Dielectric Fluid and Novel Insulation System for its Use", IEEE/PES T & D Conf., Apr. 12 -16, 1999.
    • (1999) IEEE/PES T & D Conf.
    • McShane, C.P.1    Gauger, G.A.2    Luksich, J.3
  • 2
    • 0035680382 scopus 로고    scopus 로고
    • Aging of paper insulation in natural ester dielectric fluid
    • Oct., No. 0-7803-7287-5/01 ©2001 IEEE
    • McShane et. al., "Aging of Paper Insulation in Natural Ester Dielectric Fluid", IEEE/PES T&D Conf., Oct. 2001, No. 0-7803-7287-5/01 ©2001 IEEE.
    • (2001) IEEE/PES T&D Conf.
    • McShane1
  • 4
    • 0037849298 scopus 로고    scopus 로고
    • An analysis of transformer failures
    • Hartford Steam Boiler I. & I. Co
    • Bartley, William; An Analysis of Transformer Failures, The Locomotive. Hartford Steam Boiler I. & I. Co, 1997..
    • (1997) The Locomotive
    • Bartley, W.1
  • 5
    • 0035388350 scopus 로고    scopus 로고
    • Relative properties of the new combustion-resistant vegetable oil-based dielectric coolants for distribution and power transformers
    • July/August, NO. 0093-9994/01 ©2001 IEEE
    • McShane, C.P.; "Relative Properties of the New Combustion-Resistant Vegetable Oil-Based Dielectric Coolants for Distribution and Power Transformers", IEEE Transactions on Industry Applications. Vol. 37, No. 4, July/August 2001, pp. 1132-1139, NO. 0093-9994/01 ©2001 IEEE.
    • (2001) IEEE Transactions on Industry Applications , vol.37 , Issue.4 , pp. 1132-1139
    • McShane, C.P.1
  • 6
    • 0036575664 scopus 로고    scopus 로고
    • Vegetable-oil-based dielectric coolants
    • May/June, No. 1077-2618/02, ©2002 IEEE
    • McShane, C.P., "Vegetable-Oil-Based Dielectric Coolants", IEEE Industry Applications Magazine. Vol. 8, No. 3, May/June 2002, pps.34-41, No. 1077-2618/02, ©2002 IEEE.
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 34-41
    • McShane, C.P.1
  • 7
    • 0036874728 scopus 로고    scopus 로고
    • Power engineering effective solution: A case history on meeting energy let-through requirements for a distribution transformer
    • November/December, NO0093-9994/02. ©2002 IEEE
    • Moylan, W.J., McShane, C.P., Corkran, J.L., Pierce, A., "Power Engineering Effective Solution: A Case History on Meeting Energy Let-Through Requirements for a Distribution Transformer", IEEE Transactions on Industry Applications. Vol.38, No.6, November/December 2002, pps. 1714-1721, NO0093-9994/02. ©2002 IEEE.
    • (2002) IEEE Transactions on Industry Applications , vol.38 , Issue.6 , pp. 1714-1721
    • Moylan, W.J.1    McShane, C.P.2    Corkran, J.L.3    Pierce, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.