메뉴 건너뛰기




Volumn 67, Issue 1, 2003, Pages 107-112

To what extent can digital images obtained with a non-isocentric C-arm be used for brachytherapy treatment planning in gynaecology

Author keywords

Filmless brachytherapy; Non isocentric C arm X ray unit; Variable angle reconstruction

Indexed keywords

ACCURACY; ARTICLE; BRACHYTHERAPY; DEVICE; FLUOROSCOPY; IMAGE ANALYSIS; PRIORITY JOURNAL; SIMULATION; TREATMENT OUTCOME; TREATMENT PLANNING; UTERINE CERVIX CARCINOMA;

EID: 0037692704     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(03)00027-6     Document Type: Article
Times cited : (9)

References (9)
  • 1
    • 0037562150 scopus 로고
    • Aspects of brachytherapy treatment planning: 3D and modern imaging techniques
    • Baue B., van der Laarse R. Aspects of brachytherapy treatment planning: 3D and modern imaging techniques. Int Select Brach J, Special Rep. 6:1995;70-74.
    • (1995) Int Select Brach J, Special Rep , vol.6 , pp. 70-74
    • Baue, B.1    Van der Laarse, R.2
  • 2
    • 0034751724 scopus 로고    scopus 로고
    • Clinical use of a non-isocentric C-arm unit for on-line filmless reconstruction of brachytherapy applicators
    • Cuijpers J.P. Clinical use of a non-isocentric C-arm unit for on-line filmless reconstruction of brachytherapy applicators. Radiother Oncol. 61:(2):2001;203-209.
    • (2001) Radiother Oncol , vol.61 , Issue.2 , pp. 203-209
    • Cuijpers, J.P.1
  • 3
    • 0036159393 scopus 로고    scopus 로고
    • Quality control of brachytherapy equipment in the Netherlands and Belgium: Current practice and minimum requirements
    • Elfrink R.J.M., Kolkman-Deurloo I.K., van Kleffens H.J., et al. Quality control of brachytherapy equipment in the Netherlands and Belgium: current practice and minimum requirements. Radiother Oncol. 62:(1):2002;95-102.
    • (2002) Radiother Oncol , vol.62 , Issue.1 , pp. 95-102
    • Elfrink, R.J.M.1    Kolkman-Deurloo, I.K.2    Van Kleffens, H.J.3
  • 4
    • 0035915779 scopus 로고    scopus 로고
    • Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects
    • Fellner C., Pötter R., Knocke T.H., Wambersie A. Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects. Radiother Oncol. 58:(1):2001;53-62.
    • (2001) Radiother Oncol , vol.58 , Issue.1 , pp. 53-62
    • Fellner, C.1    Pötter, R.2    Knocke, T.H.3    Wambersie, A.4
  • 5
    • 0012670889 scopus 로고    scopus 로고
    • Radiography compared to sectional image (CT/MR) based 3D treatment planning in cervix cancer brachytherapy: Results of a prospective trial
    • Gerstner N., Watchter S., Knocke H.T., et al. Radiography compared to sectional image (CT/MR) based 3D treatment planning in cervix cancer brachytherapy: results of a prospective trial. Radiother Oncol. 60(suppl. 1):2001;S3.
    • (2001) Radiother Oncol , vol.60 , Issue.SUPPL. 1 , pp. 3
    • Gerstner, N.1    Watchter, S.2    Knocke, H.T.3
  • 7
    • 0030872705 scopus 로고    scopus 로고
    • Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy
    • Kolkman-Deurloo I.K., Visser A.G., Idzes M.H.M., Levendag P.C. Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy. Radiother Oncol. (44):1997;73-81.
    • (1997) Radiother Oncol , Issue.44 , pp. 73-81
    • Kolkman-Deurloo, I.K.1    Visser, A.G.2    Idzes, M.H.M.3    Levendag, P.C.4
  • 8
    • 0031914319 scopus 로고    scopus 로고
    • Changes in high-dose-rate tandem and ovoid applicator positions during treatment in an unfixed brachytherapy system
    • Pham H.T., Chen Y., Rouby E., Lustig A., Wallner P.A. Changes in high-dose-rate tandem and ovoid applicator positions during treatment in an unfixed brachytherapy system. Radiology. 206:(2):1998;525-531.
    • (1998) Radiology , vol.206 , Issue.2 , pp. 525-531
    • Pham, H.T.1    Chen, Y.2    Rouby, E.3    Lustig, A.4    Wallner, P.A.5
  • 9
    • 0025837262 scopus 로고
    • Accurate characterisation of image intensifier distortion
    • Rudin S., Bednarek R.D., Wong R. Accurate characterisation of image intensifier distortion. Med Phys. 18:(6):1991;1145-1151.
    • (1991) Med Phys , vol.18 , Issue.6 , pp. 1145-1151
    • Rudin, S.1    Bednarek, R.D.2    Wong, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.