메뉴 건너뛰기




Volumn 18, Issue 9, 2003, Pages 1109-1114

Modification of ISFETs with a monolayer of latex beads for specific detection of proteins

Author keywords

Antibodies; Biosensor; ImmunoFET; ISFET; Latex beads

Indexed keywords

ADSORPTION; ION SENSITIVE FIELD EFFECT TRANSISTORS; MONOLAYERS; PROTEINS;

EID: 0037684737     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(02)00243-9     Document Type: Article
Times cited : (35)

References (13)
  • 1
    • 12444259090 scopus 로고    scopus 로고
    • ISFET affinity sensor
    • A. Mulchandani, & K. Rogers. Totowa, NJ: Humana Press. Chapter 12
    • Besselink G.A.J., Bergveld P. ISFET affinity sensor. Mulchandani A., Rogers K. Methods in Biotechnology. 7:1998;Humana Press, Totowa, NJ. Chapter 12.
    • (1998) Methods in Biotechnology , vol.7
    • Besselink, G.A.J.1    Bergveld, P.2
  • 2
    • 0032636732 scopus 로고    scopus 로고
    • New amperometric and potentiometric immunosensors for anti-human immunoglobulin G determinations
    • Campanella L., Attioli R., Colapicchioni C., Tomassetti M. New amperometric and potentiometric immunosensors for anti-human immunoglobulin G determinations. Sens. Actuat. B. 55:1999;23-32.
    • (1999) Sens. Actuat. B , vol.55 , pp. 23-32
    • Campanella, L.1    Attioli, R.2    Colapicchioni, C.3    Tomassetti, M.4
  • 3
    • 0031277833 scopus 로고    scopus 로고
    • An ISFET-based dipstick device for protein detection using the ion-step method
    • Eijkel J.C.T., Olthuis W., Bergveld P. An ISFET-based dipstick device for protein detection using the ion-step method. Biosens. Bioelectron. 12:1997;991-1001.
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 991-1001
    • Eijkel, J.C.T.1    Olthuis, W.2    Bergveld, P.3
  • 4
    • 0030615769 scopus 로고    scopus 로고
    • Measuring Donnan-related phenomena using a solid-state ion sensor and a concentration-step method
    • Eijkel J.C.T., Olthuis W., Kolev S.D., Bergveld P. Measuring Donnan-related phenomena using a solid-state ion sensor and a concentration-step method. J. Membr. Sci. 127:1997;203-221.
    • (1997) J. Membr. Sci. , vol.127 , pp. 203-221
    • Eijkel, J.C.T.1    Olthuis, W.2    Kolev, S.D.3    Bergveld, P.4
  • 5
    • 0033724036 scopus 로고    scopus 로고
    • Study on highly sensitive potentiometric IgG immunosensor
    • Feng C.-L., Xu Y.-H., Song L.-M. Study on highly sensitive potentiometric IgG immunosensor. Sens. Actuat. B. 66:2000;190-192.
    • (2000) Sens. Actuat. B , vol.66 , pp. 190-192
    • Feng, C.-L.1    Xu, Y.-H.2    Song, L.-M.3
  • 6
    • 0033972703 scopus 로고    scopus 로고
    • Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor
    • Lee W.E., Thompson H.G., Hall J.G., Bader D.E. Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor. Biosens. Bioelectron. 14:2000;795-804.
    • (2000) Biosens. Bioelectron. , vol.14 , pp. 795-804
    • Lee, W.E.1    Thompson, H.G.2    Hall, J.G.3    Bader, D.E.4
  • 7
    • 0035161282 scopus 로고    scopus 로고
    • Immunosensors - Principles and applications to clinical chemistry
    • Luppa P.B., Sokoll L.J., Chan D.W. Immunosensors - principles and applications to clinical chemistry. Clin. Chim. Acta. 314:2001;1-26.
    • (2001) Clin. Chim. Acta , vol.314 , pp. 1-26
    • Luppa, P.B.1    Sokoll, L.J.2    Chan, D.W.3
  • 8
    • 0025036653 scopus 로고
    • Possibilities and limitations of direct detection of protein charges by means of an immunological field-effect transistor
    • Schasfoort R.B.M., Bergveld P., Kooyman R.P.H., Greve J. Possibilities and limitations of direct detection of protein charges by means of an immunological field-effect transistor. Anal. Chim. Acta. 238:1990;323-329.
    • (1990) Anal. Chim. Acta , vol.238 , pp. 323-329
    • Schasfoort, R.B.M.1    Bergveld, P.2    Kooyman, R.P.H.3    Greve, J.4
  • 11
    • 0027764611 scopus 로고
    • Development of an ISFET based heparin sensor using the ion-step measuring method
    • Van Kerkhof J.C., Bergveld P., Schasfoort R.B.M. Development of an ISFET based heparin sensor using the ion-step measuring method. Biosens. Bioelectron. 8:1993;463-472.
    • (1993) Biosens. Bioelectron. , vol.8 , pp. 463-472
    • Van Kerkhof, J.C.1    Bergveld, P.2    Schasfoort, R.B.M.3
  • 12
    • 0028386758 scopus 로고
    • ISFET responses on a stepwise change in electrolyte concentration at constant pH
    • Van Kerkhof J.C., Eijkel J.C.T., Bergveld P. ISFET responses on a stepwise change in electrolyte concentration at constant pH. Sens. Actuat. B. 18:1994;56-59.
    • (1994) Sens. Actuat. B , vol.18 , pp. 56-59
    • Van Kerkhof, J.C.1    Eijkel, J.C.T.2    Bergveld, P.3
  • 13
    • 0029256549 scopus 로고
    • The ISFET-based heparin sensor with a monolayer of protamine as affinity ligand
    • Van Kerkhof J.C., Bergveld P., Schasfoort R.B.M. The ISFET-based heparin sensor with a monolayer of protamine as affinity ligand. Biosens. Bioelectron. 10:1995;269-282.
    • (1995) Biosens. Bioelectron. , vol.10 , pp. 269-282
    • Van Kerkhof, J.C.1    Bergveld, P.2    Schasfoort, R.B.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.