1
-
-
0030312032
-
A Theoretical Model for Predicting Adiabatic Capillary Tube Performance with Alternative Refrigerants
-
Bittle, R. R., and Pate, M. B., 1996. A Theoretical Model for Predicting Adiabatic Capillary Tube Performance with Alternative Refrigerants. ASHRAE Transactions, 102 (2):52–64.
-
(1996)
ASHRAE Transactions
, vol.102
, Issue.2
, pp. 52-64
-
-
Bittle, R.R.1
Pate, M.B.2
-
4
-
-
85023802272
-
-
Proceedings of 1998 International Refrigeration Conference, Purdue
-
Fiorelli, F. A. S., Peixoto, R. A., Paiva, M. A. S., and Silvares, O. M., Numerical Study on Refrigerant Mixtures Flow in Capillary Tubes. Proceedings of 1998 International Refrigeration Conference. Purdue. pp. 413–418.
-
Numerical Study on Refrigerant Mixtures Flow in Capillary Tubes
, pp. 413-418
-
-
Fiorelli, F.A.S.1
Peixoto, R.A.2
Paiva, M.A.S.3
Silvares, O.M.4
-
5
-
-
85023821696
-
-
Proceedings of 20th International Congress of Refrigeration, Sydney
-
Fiorelli, F. A. S., Peixoto, R. A., Paiva, M. A. S., and Silvares, O. M., Analysis of R-410A and R-407C Flow Through Capillary Tubes Using a Separated Flow Model. Proceedings of 20th International Congress of Refrigeration. Sydney.
-
Analysis of R-410A and R-407C Flow Through Capillary Tubes Using a Separated Flow Model
-
-
Fiorelli, F.A.S.1
Peixoto, R.A.2
Paiva, M.A.S.3
Silvares, O.M.4
-
6
-
-
0020113007
-
Change in Mean Gas Hold-Up with Variation of Independent Parameters in Horizontal and Vertical Up- and Downflow
-
Friedel, L., 1982. Change in Mean Gas Hold-Up with Variation of Independent Parameters in Horizontal and Vertical Up- and Downflow. German Journal of Chemical Engineering, 5:79–87.
-
(1982)
German Journal of Chemical Engineering
, vol.5
, pp. 79-87
-
-
Friedel, L.1
-
7
-
-
0031276534
-
The Surface Tension of HFC Refrigerants and Mixtures
-
Heide, R., 1997. The Surface Tension of HFC Refrigerants and Mixtures. International Journal of Refrigeration, 20 (7):496–503.
-
(1997)
International Journal of Refrigeration
, vol.20
, Issue.7
, pp. 496-503
-
-
Heide, R.1
-
10
-
-
0033334642
-
Capillary Tube Selection for HCFC22 Alternatives
-
Jung, D., Park, C., and Park, B., 1999. Capillary Tube Selection for HCFC22 Alternatives. International Journal of Refrigeration, 22:604–614.
-
(1999)
International Journal of Refrigeration
, vol.22
, pp. 604-614
-
-
Jung, D.1
Park, C.2
Park, B.3
-
12
-
-
0026051053
-
Local Frictional Pressure Drop During Vaporization of R-12 Through Capillary Tubes
-
Lin, S., Kwok, C. C. K., Li, R. Y., Chen, Z. H., and Chen, Z. Y., 1991. Local Frictional Pressure Drop During Vaporization of R-12 Through Capillary Tubes. International Journal of Multiphase Flow, 17 (1):95–102.
-
(1991)
International Journal of Multiphase Flow
, vol.17
, Issue.1
, pp. 95-102
-
-
Lin, S.1
Kwok, C.C.K.2
Li, R.Y.3
Chen, Z.H.4
Chen, Z.Y.5
-
13
-
-
0031699670
-
New Insights into the Behavior of the Metastable Region of an Operating Capillary Tube
-
Meyer, J. J., and Dunn, W. E., 1998. New Insights into the Behavior of the Metastable Region of an Operating Capillary Tube. International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research, 4 (1):105–115.
-
(1998)
International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research
, vol.4
, Issue.1
, pp. 105-115
-
-
Meyer, J.J.1
Dunn, W.E.2
-
14
-
-
0001889709
-
Adiabatic Single and Two Phase Flow in Small Bore Tubes
-
Mikol, E. P., 1963. Adiabatic Single and Two Phase Flow in Small Bore Tubes. ASHRAE Journal, 5:75–88.
-
(1963)
ASHRAE Journal
, vol.5
, pp. 75-88
-
-
Mikol, E.P.1
-
15
-
-
0033685311
-
Critical Flow of Refrigerants Through Adiabatic Capillary Tubes: Experimental Study of Zeotropic Mixtures R-407C and R-404A
-
Motta, S. Y., Braga, S. L., and Parise, J. A. R., 2000. Critical Flow of Refrigerants Through Adiabatic Capillary Tubes:Experimental Study of Zeotropic Mixtures R-407C and R-404A. ASHRAE Transactions, 106 (1):534–549.
-
(2000)
ASHRAE Transactions
, vol.106
, Issue.1
, pp. 534-549
-
-
Motta, S.Y.1
Braga, S.L.2
Parise, J.A.R.3
-
17
-
-
85023817631
-
-
Proceedings of the 19th International Congress of Refrigeration, The Hague, IIIa
-
Paiva, M. A. S., Fiorelli, F. A. S., Peixoto, R. A., Vodianitskaia, P., Hernandez, A. N., and Silvares, O. M., Experimental and Numerical Study of the Flow Through Non Adiabatic Capillary Tubes with Lateral and Concentric Capillary Tube-Suction Line Heat Exchanger Configuration. Proceedings of the 19th International Congress of Refrigeration. The Hague, IIIa. pp. 429–436.
-
Experimental and Numerical Study of the Flow Through Non Adiabatic Capillary Tubes with Lateral and Concentric Capillary Tube-Suction Line Heat Exchanger Configuration
, pp. 429-436
-
-
Paiva, M.A.S.1
Fiorelli, F.A.S.2
Peixoto, R.A.3
Vodianitskaia, P.4
Hernandez, A.N.5
Silvares, O.M.6
-
20
-
-
85023801867
-
-
Proceedings of the Emerging Trends in Refrigeration and Air Conditioning (Proceedings of Joint Meeting of IIR Sections B/E), New Delhi
-
Peixoto, R. A., Fiorelli, F. A. S., Paiva, M. A. S., and Silvares, O. M., Numerical Simulation of Capillary Tube-Suction Line Heat Exchangers Using CFC-12, R-401A, R-409A and HC Blend. Proceedings of the Emerging Trends in Refrigeration and Air Conditioning (Proceedings of Joint Meeting of IIR Sections B/E). New Delhi. pp. 248–256.
-
Numerical Simulation of Capillary Tube-Suction Line Heat Exchangers Using CFC-12, R-401A, R-409A and HC Blend
, pp. 248-256
-
-
Peixoto, R.A.1
Fiorelli, F.A.S.2
Paiva, M.A.S.3
Silvares, O.M.4
-
21
-
-
0003046658
-
Una Correlazione Adimensionale per la Determinazione della Densità di Miscele Bifasiche
-
Premoli, A., Di Francesco, D., and Prina, A., 1971. Una Correlazione Adimensionale per la Determinazione della Densità di Miscele Bifasiche. La Termotecnica, 25 (1):17–25.
-
(1971)
La Termotecnica
, vol.25
, Issue.1
, pp. 17-25
-
-
Premoli, A.1
Di Francesco, D.2
Prina, A.3
-
22
-
-
0032125350
-
Modelling of Capillary Tubes Behavior with HCFC-22 Ternary Alternative Refrigerants
-
Sami, S. M., Poirier, B., and Dahamani, A. B., 1998. Modelling of Capillary Tubes Behavior with HCFC-22 Ternary Alternative Refrigerants. International Journal of Energy Research, 22:843–855.
-
(1998)
International Journal of Energy Research
, vol.22
, pp. 843-855
-
-
Sami, S.M.1
Poirier, B.2
Dahamani, A.B.3
-
23
-
-
0032090223
-
Numerical Prediction of Capillary Tube Behavior with Pure and Binary Alternative Refrigerants
-
Sami, S. M., and Tribes, C., 1998. Numerical Prediction of Capillary Tube Behavior with Pure and Binary Alternative Refrigerants. Applied Thermal Engineering, 18 (6):491–502.
-
(1998)
Applied Thermal Engineering
, vol.18
, Issue.6
, pp. 491-502
-
-
Sami, S.M.1
Tribes, C.2
-
26
-
-
0030190309
-
Adiabatic Capillary Tube Expansion Devices: A Comparison of the Homogeneous Flow and Separated Flow Models
-
Wong, T. N., and Ooi, K. T., 1996. Adiabatic Capillary Tube Expansion Devices:A Comparison of the Homogeneous Flow and Separated Flow Models. Applied Thermal Engineering, 16 (7):625–634.
-
(1996)
Applied Thermal Engineering
, vol.16
, Issue.7
, pp. 625-634
-
-
Wong, T.N.1
Ooi, K.T.2
|