Volumn 46, Issue 2, 2003, Pages 126-132
|
Non-destructive evaluation method for far-side corrosion type flaws in oil storage tank bottom floors using the magnetic flux leakage technique
|
Author keywords
Bottom floor; Corrosive type flaw; Magnetic leakage field; Non destructive testing; Oil storage tank
|
Indexed keywords
|
EID: 0037652105
PISSN: 05824664
EISSN: None
Source Type: Journal
DOI: 10.1627/jpi.46.126 Document Type: Article |
Times cited : (20)
|
References (11)
|