메뉴 건너뛰기




Volumn 23, Issue 1, 2003, Pages 88-92

Development of an optical fiber transient magnetic field sensor and its application

Author keywords

Digital frequency balance; Optical fiber sensor; Substation; Switching operations; Transient magnetic field

Indexed keywords

ELECTRIC SUBSTATIONS; MAGNETIC FIELD MEASUREMENT; PERFORMANCE; TRANSIENTS; VOLTAGE MEASUREMENT;

EID: 0037628008     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (22)

References (8)
  • 1
    • 0037839819 scopus 로고    scopus 로고
    • Study on EM disturbance in 500 kV substation and protection measures
    • Sun Zhusen, Zhang Yufang, Zhang Guangzhou, et al. Study on EM disturbance in 500 kV substation and protection measures [J]. High Voltage Engineering, 2000, 26 (1): 16-18.
    • (2000) High Voltage Engineering , vol.26 , Issue.1 , pp. 16-18
    • Sun, Z.1    Zhang, Y.2    Zhang, G.3
  • 2
    • 0037839816 scopus 로고    scopus 로고
    • Immunity requirement for protection and control equipment in 500 kV substation
    • State Economic and Trade Commission of China, DL/Z713-2000
    • State Economic and Trade Commission of China. Immunity requirement for protection and control equipment in 500 kV substation [S]. DL/Z713-2000, 2000.
    • (2000)
  • 5
    • 70349165515 scopus 로고    scopus 로고
    • Radiated transient measurement as operations in substations: Preliminary results
    • Pertorus P H, Britten A C, Jpreynders. Radiated transient measurement as operations in substations: preliminary results [C]. CIGRE 1996.
    • (1996) CIGRE
    • Pertorus, P.H.1    Britten, A.C.2    Jpreynders3
  • 6
    • 85060878555 scopus 로고
    • Comparison of interference from switching, lightning and fault events in high voltage substations
    • Wiggins C, Nilsson S. Comparison of interference from switching, lightning and fault events in high voltage substations [C]. CIGRE 1994.
    • (1994) CIGRE
    • Wiggins, C.1    Nilsson, S.2
  • 7
    • 84880072380 scopus 로고
    • Maximizing frequency response of a B-dot loop
    • Air Force Weapons Laboratory
    • Baum C E. Maximizing frequency response of a B-dot loop [R]. Air Force Weapons Laboratory, 1964, Sensor and Simulation Notes VIII: 2.
    • (1964) Sensor and Simulation Notes , vol.8 , pp. 2
    • Baum, C.E.1
  • 8
    • 0003698025 scopus 로고
    • Beijing: People's Post and Telecommunications Publishing House
    • Kraus J D. Electromagnetics. Beijing: People's Post and Telecommunications Publishing House, 1979.
    • (1979) Electromagnetics
    • Kraus, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.