메뉴 건너뛰기




Volumn 202, Issue 4, 2003, Pages 397-407

Pollical oblique ligament in humans and non-human primates

Author keywords

Flexor superficialis tendon; Oblique ligament; Pollex; Pollical annular pulley; Pollical flexor sheath

Indexed keywords

ANIMAL TISSUE; ARTICLE; BABOON; CHIMPANZEE; COMPARATIVE ANATOMY; CONTROLLED STUDY; DISSECTION; DISTAL PHALANX; FEMALE; FLEXOR TENDON; HUMAN; HUMAN TISSUE; INTERPHALANGEAL JOINT; LIGAMENT; MALE; MARMOSET; MORPHOLOGY; NONHUMAN; ORANG UTAN; PRIORITY JOURNAL; PROSIMIAN; SPECIES DIFFERENCE; SQUIRREL MONKEY; THUMB;

EID: 0037621908     PISSN: 00218782     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1469-7580.2003.00172.x     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 0014329996 scopus 로고
    • The mechanics of normal digital control in the hand and an analysis of the ulnar drift of rheumatoid arthritis
    • Backhouse KM (1968) The mechanics of normal digital control in the hand and an analysis of the ulnar drift of rheumatoid arthritis. Ann. Royal College Surgery England 43, 154-173.
    • (1968) Ann. Royal College Surgery England , vol.43 , pp. 154-173
    • Backhouse, K.M.1
  • 2
    • 0036068481 scopus 로고    scopus 로고
    • The pulley system of the thumb: Anatomic and biomechanical study
    • Bayat A, Shaaban H, Giakas G, Lees VC (2002) The pulley system of the thumb: anatomic and biomechanical study. J. Hand Surg. (Am.) 27, 628-635.
    • (2002) J. Hand Surg. (Am.) , vol.27 , pp. 628-635
    • Bayat, A.1    Shaaban, H.2    Giakas, G.3    Lees, V.C.4
  • 4
    • 0017337471 scopus 로고
    • Biomechanical analysis of static forces in the thumb during hand function
    • Cooney WP III, Chao EYS (1977) Biomechanical analysis of static forces in the thumb during hand function. J. Bone Joint Surgery (Am.) 59(A), 27-36.
    • (1977) J. Bone Joint Surgery (Am.) , vol.59 A , pp. 27-36
    • Cooney W.P. III1    Chao, E.Y.S.2
  • 5
    • 0024561809 scopus 로고
    • Anatomy of the flexor tendon sheath and pulley system: A current review
    • Doyle JR (1989) Anatomy of the flexor tendon sheath and pulley system: a current review. J. Hand Surg. (Am.) 14, 349-351.
    • (1989) J. Hand Surg. (Am.) , vol.14 , pp. 349-351
    • Doyle, J.R.1
  • 6
    • 0017722742 scopus 로고
    • Anatomy of the flexor tendon sheath and pulleys of the thumb
    • Doyle JR, Blythe WF (1977) Anatomy of the flexor tendon sheath and pulleys of the thumb. J. Hand Surg. (Am.) 2, 149-151.
    • (1977) J. Hand Surg. (Am.) , vol.2 , pp. 149-151
    • Doyle, J.R.1    Blythe, W.F.2
  • 7
    • 0029881662 scopus 로고    scopus 로고
    • Restoration of function of the thumb flexor apparatus requires repair of the oblique and one adjacent tendon pulley
    • Esplin VS, Tencer AF, Hanel DP, Cosio MQ (1996) Restoration of function of the thumb flexor apparatus requires repair of the oblique and one adjacent tendon pulley. J. Orthopaedic Res. 14, 152-156.
    • (1996) J. Orthopaedic Res. , vol.14 , pp. 152-156
    • Esplin, V.S.1    Tencer, A.F.2    Hanel, D.P.3    Cosio, M.Q.4
  • 8
    • 0032004110 scopus 로고    scopus 로고
    • EMG of human flexor pollicis longus muscle: Implications for evolution of hominid tool use
    • Hamrick MW, Churchill SE, Schmitt D, Hylander WL (1998) EMG of human flexor pollicis longus muscle: implications for evolution of hominid tool use. J. Human Evol. 34, 123-136.
    • (1998) J. Human Evol. , vol.34 , pp. 123-136
    • Hamrick, M.W.1    Churchill, S.E.2    Schmitt, D.3    Hylander, W.L.4
  • 11
    • 0014308133 scopus 로고
    • Intrinsic-extrinsic muscle control of the fingers. Electromyographic studies
    • Long C (1968) Intrinsic-extrinsic muscle control of the fingers. Electromyographic studies. J. Bone Joint Surg. 50A, 973-984.
    • (1968) J. Bone Joint Surg. , vol.50 A , pp. 973-984
    • Long, C.1
  • 12
    • 0031016198 scopus 로고
    • Precision grips, hand morphology, and tools
    • Marzke MW (1977) Precision grips, hand morphology, and tools. Am. J. Phys. Anthropol. 102, 91-110.
    • (1977) Am. J. Phys. Anthropol. , vol.102 , pp. 91-110
    • Marzke, M.W.1
  • 13
    • 0026545589 scopus 로고
    • Evolutionary development of the human thumb
    • Marzke MW (1992) Evolutionary development of the human thumb. Hand Clinics 8, 1-8.
    • (1992) Hand Clinics , vol.8 , pp. 1-8
    • Marzke, M.W.1
  • 14
    • 0000338136 scopus 로고    scopus 로고
    • Chimpanzee and human grips: A new classification with a focus on evolutionary morphology
    • Marzke MW, Wullstein KL (1996) Chimpanzee and human grips: a new classification with a focus on evolutionary morphology. Int. J. Primatol. 17, 117-139.
    • (1996) Int. J. Primatol. , vol.17 , pp. 117-139
    • Marzke, M.W.1    Wullstein, K.L.2
  • 15
    • 77049258175 scopus 로고
    • Prehensile movements of the human hand
    • Napier JR (1956) Prehensile movements of the human hand. J. Bone Joint Surg. 38B, 902-913.
    • (1956) J. Bone Joint Surg. , vol.38 B , pp. 902-913
    • Napier, J.R.1
  • 18
    • 0034203654 scopus 로고    scopus 로고
    • Digital flexor sheath: Repair and reconstruction of the annular pulleys and membranous sheath
    • Seiler III JG, Leversedge FJ (2000) Digital flexor sheath: repair and reconstruction of the annular pulleys and membranous sheath. J. Southern Orthropaedic. Assoc. 9, 81-90.
    • (2000) J. Southern Orthropaedic Assoc. , vol.9 , pp. 81-90
    • Seiler J.G. III1    Leversedge, F.J.2
  • 19
    • 0016153743 scopus 로고
    • Flexor digitorium superficialis tendon in the fingers of the human hand
    • Shrewsbury MM, Kuczynski K (1974) Flexor digitorium superficialis tendon in the fingers of the human hand. Hand 6, 121-133.
    • (1974) Hand , vol.6 , pp. 121-133
    • Shrewsbury, M.M.1    Kuczynski, K.2
  • 20
    • 0016488831 scopus 로고
    • The study of the flexor digitorium superficialis tendon in flexion and extension at the proximal interphalangeal joint
    • Shrewsbury MM, Tucker AB (1975) The study of the flexor digitorium superficialis tendon in flexion and extension at the proximal interphalangeal joint. Bull. Hospital Joint Diseases 36, 40-47.
    • (1975) Bull. Hospital Joint Diseases , vol.36 , pp. 40-47
    • Shrewsbury, M.M.1    Tucker, A.B.2
  • 21
    • 0022283341 scopus 로고
    • Digital flexor tendon sheath: An anatomic study
    • Strauch B, de Moura W (1985) Digital flexor tendon sheath: An anatomic study. J. Hand Surg. (Am.) 10A, 785-789.
    • (1985) J. Hand Surg. (Am.) , vol.10 A , pp. 785-789
    • Strauch, B.1    de Moura, W.2
  • 22
    • 0034836413 scopus 로고    scopus 로고
    • Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing
    • Tang JB, Xie, RG (2001) Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing. J. Hand Surg. (Am.) 26, 855-861.
    • (2001) J. Hand Surg. (Am.) , vol.26 , pp. 855-861
    • Tang, J.B.1    Xie, R.G.2
  • 23
    • 0013151446 scopus 로고
    • The insertion of the flexor pollicis longus et digitorium profundus
    • Wilkinson JL (1953) The insertion of the flexor pollicis longus et digitorium profundus. J. Anat. 87, 75-91.
    • (1953) J. Anat. , vol.87 , pp. 75-91
    • Wilkinson, J.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.