메뉴 건너뛰기




Volumn 28, Issue 11, 2003, Pages 1097-1102

Effects of a cervical compression plate on graft forces in an anterior cervical discectomy model

Author keywords

Anterior interbody fusion; Biomechanics; Cervical spine; Corpectomy; Graft; Mechanics; Spinal instrumentation; Strut

Indexed keywords

ADULT; AGED; ANTERIOR SPINE FUSION; ARTICLE; BIOMECHANICS; BONE GRAFT; CADAVER; CERVICAL SPINE; CLINICAL ARTICLE; EXPERIMENTAL MODEL; HUMAN; HUMAN TISSUE; INTERVERTEBRAL ARTICULATION; INTERVERTEBRAL DISK; INTERVERTEBRAL DISKECTOMY; PRIORITY JOURNAL; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE; WEIGHT BEARING;

EID: 0037603096     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BRS.0000067268.43446.8C     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0031434250 scopus 로고    scopus 로고
    • Trends and complications in cervical spine surgery: 1989-1993
    • Zeidman SM, Ducker TB, Raycroft J. Trends and complications in cervical spine surgery: 1989-1993. J Spinal Disord 1997;10:523-6.
    • (1997) J Spinal Disord , vol.10 , pp. 523-526
    • Zeidman, S.M.1    Ducker, T.B.2    Raycroft, J.3
  • 2
    • 0025975902 scopus 로고
    • Treatment of cervical spine injuries with anterior plating, indications, techniques, and results
    • Aebi M, Zuber K, Marchesi D. Treatment of cervical spine injuries with anterior plating, indications, techniques, and results. Spine 1991;16: S38-45.
    • (1991) Spine , vol.16
    • Aebi, M.1    Zuber, K.2    Marchesi, D.3
  • 3
    • 0031017884 scopus 로고    scopus 로고
    • Anterior plate instrumentation for disorders of the subaxial cervical spine
    • Vaccaro AR, Balderston RA. Anterior plate instrumentation for disorders of the subaxial cervical spine. Clin Orthop 1997;225:112-21.
    • (1997) Clin Orthop , vol.225 , pp. 112-121
    • Vaccaro, A.R.1    Balderston, R.A.2
  • 4
    • 0029894918 scopus 로고    scopus 로고
    • Biomechanical evaluation of Caspar and cervical spine locking plate systems in a cadaveric model
    • Clausen JD, Ryken TC, Traynelis VC, et al. Biomechanical evaluation of Caspar and cervical spine locking plate systems in a cadaveric model. J Neurosurg 1996;84:1039-45.
    • (1996) J Neurosurg , vol.84 , pp. 1039-1045
    • Clausen, J.D.1    Ryken, T.C.2    Traynelis, V.C.3
  • 5
    • 0029086755 scopus 로고
    • Esophageal perforation subsequent to anterior cervical spine screw/plate fixation
    • Hanci M, Toprak M, Sarioglu AC, et al. Esophageal perforation subsequent to anterior cervical spine screw/plate fixation. Paraplegia 1995;33:606-9.
    • (1995) Paraplegia , vol.33 , pp. 606-609
    • Hanci, M.1    Toprak, M.2    Sarioglu, A.C.3
  • 6
    • 0026793528 scopus 로고
    • Esophageal Perforation after anterior cervical plate fixation: A report of two cases
    • Smith MD, Bolesta MJ. Esophageal Perforation after anterior cervical plate fixation: a report of two cases. J Spinal Disord 1992;5:357-62.
    • (1992) J Spinal Disord , vol.5 , pp. 357-362
    • Smith, M.D.1    Bolesta, M.J.2
  • 7
    • 0018119591 scopus 로고
    • Atrophy of cortical bone caused by rigid internal fixation plates
    • Stromberg L, Dalen N. Atrophy of cortical bone caused by rigid internal fixation plates. Acta Orthop Scand 1978;49:448-56.
    • (1978) Acta Orthop Scand , vol.49 , pp. 448-456
    • Stromberg, L.1    Dalen, N.2
  • 8
    • 0033998138 scopus 로고    scopus 로고
    • Anterior cervical plating reverses load transfer through multilevel strut-grafts
    • DiAngelo DJ, Foley KT, Vossel KA, et al. Anterior cervical plating reverses load transfer through multilevel strut-grafts. Spine 2000;25:783-95.
    • (2000) Spine , vol.25 , pp. 783-795
    • DiAngelo, D.J.1    Foley, K.T.2    Vossel, K.A.3
  • 9
    • 0028046043 scopus 로고
    • Biomechanical analysis of facet and graft loading in a Smith-Robinson type cervical spine model
    • Olsewski JM, Garvey TA, Schendel MJ. Biomechanical analysis of facet and graft loading in a Smith-Robinson type cervical spine model. Spine 1994;19:2540-4.
    • (1994) Spine , vol.19 , pp. 2540-2544
    • Olsewski, J.M.1    Garvey, T.A.2    Schendel, M.J.3
  • 10
    • 0029891765 scopus 로고    scopus 로고
    • Radiographic and clinical follow-up review of Caspar plates in 49 patients
    • Paramore CG, Dickman CA, Sonntag VK. Radiographic and clinical follow-up review of Caspar plates in 49 patients. J Neurosurg 1996;84:957-61.
    • (1996) J Neurosurg , vol.84 , pp. 957-961
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.3
  • 12
    • 0028152706 scopus 로고
    • The Synthes cervical spine locking plate and screw system in anterior cervical fusion
    • Rechtine GR, Cahill DW, Gruenberg M, et al. The Synthes cervical spine locking plate and screw system in anterior cervical fusion. Tech Orthop 1994;9:86-91.
    • (1994) Tech Orthop , vol.9 , pp. 86-91
    • Rechtine, G.R.1    Cahill, D.W.2    Gruenberg, M.3
  • 13
    • 0025991218 scopus 로고
    • Failure of halo vest to prevent in vivo motion in patients with injured cervical spines
    • Anderson PA, Budorick TE, Easton KB, et al. Failure of halo vest to prevent in vivo motion in patients with injured cervical spines. Spine 1991;16(Suppl):S72-9.
    • (1991) Spine , vol.16 , Issue.SUPPL.
    • Anderson, P.A.1    Budorick, T.E.2    Easton, K.B.3
  • 14
    • 0035870878 scopus 로고    scopus 로고
    • Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion
    • Lim T-H, Kwon H, Jeon C-H, et al. Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion. Spine 2001;26:951-6.
    • (2001) Spine , vol.26 , pp. 951-956
    • Lim, T.-H.1    Kwon, H.2    Jeon, C.-H.3
  • 16
    • 0035868874 scopus 로고    scopus 로고
    • Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion
    • Wang JC, McDonough PW, Kanim LE, et al. Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion. Spine 2001;26:643-6.
    • (2001) Spine , vol.26 , pp. 643-646
    • Wang, J.C.1    McDonough, P.W.2    Kanim, L.E.3
  • 17
    • 0025010087 scopus 로고
    • Compressive strength of autologous and allogenous bone grafts for thoracolumbar and cervical spine fusion
    • Wittenberg RH, Moeller J, Shea M, et al. Compressive strength of autologous and allogenous bone grafts for thoracolumbar and cervical spine fusion. Spine 1990;15:1073-8.
    • (1990) Spine , vol.15 , pp. 1073-1078
    • Wittenberg, R.H.1    Moeller, J.2    Shea, M.3
  • 18
    • 0035876116 scopus 로고    scopus 로고
    • Dynamic cervical plates: Biomechanical evaluation of load sharing and stiffness
    • Brodke DS, Gollogly S, Alexander Mohr R, et al. Dynamic cervical plates: biomechanical evaluation of load sharing and stiffness. Spine 2001;26:1324-9.
    • (2001) Spine , vol.26 , pp. 1324-1329
    • Brodke, D.S.1    Gollogly, S.2    Alexander Mohr, R.3
  • 19
    • 0032732256 scopus 로고    scopus 로고
    • The in vitro effects of instrumentation on multilevel cervical strut graft mechanics
    • Foley KT, DiAngelo DJ, Rampersaud YR, et al. The in vitro effects of instrumentation on multilevel cervical strut graft mechanics. Spine 1999;24:2366-76.
    • (1999) Spine , vol.24 , pp. 2366-2376
    • Foley, K.T.1    DiAngelo, D.J.2    Rampersaud, Y.R.3
  • 20
    • 0000441855 scopus 로고
    • Anterolateral cervical disc removal and interbody fusion for cervical disc syndrome
    • Robinson RA, Smith GW. Anterolateral cervical disc removal and interbody fusion for cervical disc syndrome. Bull Johns Hopkins Hosp 1955;96:223-4.
    • (1955) Bull Johns Hopkins Hosp , vol.96 , pp. 223-224
    • Robinson, R.A.1    Smith, G.W.2
  • 21
    • 0027517661 scopus 로고
    • Ideal thickness of Smith-Robinson anterior cervical interbody graft
    • An HS, Evanich C, Nowichi B, et al. Ideal thickness of Smith-Robinson anterior cervical interbody graft. Spine 1993;18:2043-7.
    • (1993) Spine , vol.18 , pp. 2043-2047
    • An, H.S.1    Evanich, C.2    Nowichi, B.3
  • 22
    • 0023786685 scopus 로고
    • The vertical stability of the cervical spine
    • Pal GP, Sherk HH. The vertical stability of the cervical spine. Spine 1988;13:447-9.
    • (1988) Spine , vol.13 , pp. 447-449
    • Pal, G.P.1    Sherk, H.H.2
  • 23
    • 0029957840 scopus 로고    scopus 로고
    • A proposed technique for intraoperative measurement of cervical spine stiffness
    • Frank E, Chamberland D, Ragel B. A proposed technique for intraoperative measurement of cervical spine stiffness. Neurosurgery 1996;39:147-50.
    • (1996) Neurosurgery , vol.39 , pp. 147-150
    • Frank, E.1    Chamberland, D.2    Ragel, B.3
  • 24
    • 0015847880 scopus 로고
    • An experimental study of the immediate load bearing capacity of three surgical constructions for anterior spine fusions
    • White AA III, Jupiter J, Southwick WO, et al. An experimental study of the immediate load bearing capacity of three surgical constructions for anterior spine fusions. Clin Orthop 1973;91:21-8.
    • (1973) Clin Orthop , vol.91 , pp. 21-28
    • White A.A. III1    Jupiter, J.2    Southwick, W.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.