메뉴 건너뛰기




Volumn 8, Issue 2, 2003, Pages 260-263

Speckle reduction in optical coherence tomography by "path length encoded" angular compounding

Author keywords

Catheters; Endoscopes; Optical coherence tomography; Speckle reduction

Indexed keywords

CATHETERS; COHERENT LIGHT; DISEASES; ENDOSCOPY; IMAGE QUALITY; MEDICAL IMAGING; PROBES; SIGNAL TO NOISE RATIO; SPECKLE; TISSUE; TOMOGRAPHY;

EID: 0037592974     PISSN: 10833668     EISSN: None     Source Type: Journal    
DOI: 10.1117/1.1559060     Document Type: Article
Times cited : (152)

References (12)
  • 1
    • 0034072983 scopus 로고    scopus 로고
    • High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    • B. E. Bouma, G. J. Tearney, C. C. Compton, and N. S. Nishioka, "High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography," Gastrointest. Endosc. 51, 467-474 (2000).
    • (2000) Gastrointest. Endosc. , vol.51 , pp. 467-474
    • Bouma, B.E.1    Tearney, G.J.2    Compton, C.C.3    Nishioka, N.S.4
  • 2
    • 0035432399 scopus 로고    scopus 로고
    • High-resolution endoscopic imaging of the GI tract: A comparative study of optical coherence tomography versus high-frequency catheter probe EUS
    • A. Das, M. Sivak, A. Chak, R. Wong, V. Westphal, A. Rollins, J. Willis, G. Isenberg, and J. Izatt, "High-resolution endoscopic imaging of the GI tract: a comparative study of optical coherence tomography versus high-frequency catheter probe EUS," Gastrointest. Endosc. 54, 219-224 (2001).
    • (2001) Gastrointest. Endosc. , vol.54 , pp. 219-224
    • Das, A.1    Sivak, M.2    Chak, A.3    Wong, R.4    Westphal, V.5    Rollins, A.6    Willis, J.7    Isenberg, G.8    Izatt, J.9
  • 5
    • 0030754474 scopus 로고    scopus 로고
    • Array detection for speckle reduction in optical coherence microscopy
    • J. M. Schmitt, "Array detection for speckle reduction in optical coherence microscopy," Phys. Med. Biol. 42, 1427-1429 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1427-1429
    • Schmitt, J.M.1
  • 6
    • 0000691673 scopus 로고    scopus 로고
    • Statistics and reduction of speckle in optical coherence tomography
    • M. Bashkansky and J. Reintjes, "Statistics and reduction of speckle in optical coherence tomography," Opt. Lett. 25, 545-547 (2000).
    • (2000) Opt. Lett. , vol.25 , pp. 545-547
    • Bashkansky, M.1    Reintjes, J.2
  • 7
    • 0032620384 scopus 로고    scopus 로고
    • Power-efficient nonreciprocal interferometer and linear-scanning fiber optic catheter for optical coherence tomography
    • B. E. Bouma and G. J. Tearney, "Power-efficient nonreciprocal interferometer and linear-scanning fiber optic catheter for optical coherence tomography," Opt. Lett. 24, 531-533 (1999).
    • (1999) Opt. Lett. , vol.24 , pp. 531-533
    • Bouma, B.E.1    Tearney, G.J.2
  • 8
    • 5244345537 scopus 로고    scopus 로고
    • High-speed phase- and group-delay scanning with a grating-based phase control delay line
    • G. J. Tearney, B. E. Bouma, and J. G. Fujimoto, "High-speed phase- and group-delay scanning with a grating-based phase control delay line," Opt. Lett. 22, 1811-1813 (1997).
    • (1997) Opt. Lett. , vol.22 , pp. 1811-1813
    • Tearney, G.J.1    Bouma, B.E.2    Fujimoto, J.G.3
  • 9
    • 0000150646 scopus 로고    scopus 로고
    • Optical interferometer designs for optical coherence tomography
    • A. M. Rollins and J. A. Izatt, "Optical interferometer designs for optical coherence tomography," Opt. Lett. 24, 1484-1486 (1999).
    • (1999) Opt. Lett. , vol.24 , pp. 1484-1486
    • Rollins, A.M.1    Izatt, J.A.2
  • 10
    • 0032620384 scopus 로고    scopus 로고
    • Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography
    • B. E. Bouma and G. J. Tearney, "Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography," Opt. Lett. 24, 531-533 (1999).
    • (1999) Opt. Lett. , vol.24 , pp. 531-533
    • Bouma, B.E.1    Tearney, G.J.2
  • 11
    • 0000950973 scopus 로고    scopus 로고
    • Self-phase modulated Kerr lens mode-locked Cr: Fosterite laser source for optical coherence tomography
    • B. E. Bouma, G. J. Tearney, I. P. Bilinsky, B. Golubovic, and J. G. Fujimoto, "Self-phase modulated Kerr lens mode-locked Cr: fosterite laser source for optical coherence tomography," Opt. Lett. 21, 1839-1841 (1996).
    • (1996) Opt. Lett. , vol.21 , pp. 1839-1841
    • Bouma, B.E.1    Tearney, G.J.2    Bilinsky, I.P.3    Golubovic, B.4    Fujimoto, J.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.