메뉴 건너뛰기




Volumn 13, Issue 7, 2003, Pages 1529-1533

Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels

Author keywords

Diagnostic reference levels; Intravenous urograms; Radiation doses

Indexed keywords

ARTICLE; BODY WEIGHT; CONTROLLED STUDY; DOSIMETER; DOSIMETRY; HOSPITAL; HUMAN; IMAGE ANALYSIS; INTRAVENOUS UROGRAPHY; IRELAND; MAJOR CLINICAL STUDY; PRACTICE GUIDELINE; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIOLOGY DEPARTMENT; REFERENCE VALUE; REGRESSION ANALYSIS; STANDARDIZATION; URINARY TRACT DISEASE; X RAY FILM;

EID: 0037591874     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-002-1792-5     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0037912050 scopus 로고    scopus 로고
    • Council Directive 97/43/Euratom. Health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/ 466/ Euratom
    • Council Directive 97/43/Euratom. Health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/ 466/ Euratom
  • 2
    • 0037574001 scopus 로고
    • Institute of Physical Sciences in Medicine, National Radiological Protection Board, College of Radiographers National Protocol for Patient Dose Measurements in Diagnostic Radiology, The National Radiological Protection Board, Oxon
    • Institute of Physical Sciences in Medicine, National Radiological Protection Board, College of Radiographers (1992) National Protocol for Patient Dose Measurements in Diagnostic Radiology, The National Radiological Protection Board, Oxon
    • (1992)
  • 3
    • 0031661282 scopus 로고    scopus 로고
    • Dose-area product readings for fluoroscopic and plain film examinations, including analysis of the source of variation for barium enema examinations
    • Warren-Forward HM, Haddaway MJ, Temperton DH, McCall IW (1998) Dose-area product readings for fluoroscopic and plain film examinations, including analysis of the source of variation for barium enema examinations. Br J Radiol 71:961-967
    • (1998) Br. J. Radiol. , vol.71 , pp. 961-967
    • Warren-Forward, H.M.1    Haddaway, M.J.2    Temperton, D.H.3    McCall, I.W.4
  • 4
    • 0034013277 scopus 로고    scopus 로고
    • Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals
    • Johnston DA, Brennan PC (2000) Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals. Br J Radiol 73:396-402
    • (2000) Br. J. Radiol. , vol.73 , pp. 396-402
    • Johnston, D.A.1    Brennan, P.C.2
  • 5
    • 0023853040 scopus 로고    scopus 로고
    • A comparison of diagnostic radiology practice and patient exposure in Britain, France and Italy
    • Contento G, Malisan MR, Padovani R, Maccia C, Wall F, Shrimpton PC (1998) A comparison of diagnostic radiology practice and patient exposure in Britain, France and Italy. Br J Radiol 61:143-152
    • (1998) Br. J. Radiol. , vol.61 , pp. 143-152
    • Contento, G.1    Malisan, M.R.2    Padovani, R.3    Maccia, C.4    Wall, F.5    Shrimpton, P.C.6
  • 6
    • 0003601286 scopus 로고    scopus 로고
    • Dose to patients from medical X-ray examinations in the UK 1995 review, NRPB-R289
    • National Radiological Protection Board, Oxon
    • Hart D, Hillier MC, Wall BF, Shrimpton PC, Bungay D (1996) Dose to patients from medical X-ray examinations in the UK 1995 review, NRPB-R289. National Radiological Protection Board, Oxon
    • (1996)
    • Hart, D.1    Hillier, M.C.2    Wall, B.F.3    Shrimpton, P.C.4    Bungay, D.5
  • 7
    • 0037868729 scopus 로고    scopus 로고
    • Radiation exposure of the UK population from medical and dental X-ray examinations, NRPB-W4
    • National Radiological Protection Board National Radiological Protection Board, Oxon
    • National Radiological Protection Board (2002) Radiation exposure of the UK population from medical and dental X-ray examinations, NRPB-W4. National Radiological Protection Board, Oxon
    • (2002)
  • 8
    • 0006290362 scopus 로고    scopus 로고
    • Radiation Protection 109 Guidance on diagnostic reference dose levels (DRLs) for medical exposure
    • European Commission European Communities Publications
    • European Commission (1999) Radiation Protection 109 Guidance on diagnostic reference dose levels (DRLs) for medical exposure. European Communities Publications
    • (1999)
  • 10
    • 0029883313 scopus 로고    scopus 로고
    • A comparison of tomography and zonography during intravenous urography
    • Daniels SJ, Brennan PC (1996) A comparison of tomography and zonography during intravenous urography. Radiography 2:99-109
    • (1996) Radiography , vol.2 , pp. 99-109
    • Daniels, S.J.1    Brennan, P.C.2
  • 11
    • 0037912049 scopus 로고
    • Digital radiography: Clinical experience with digital image intensifier and storage phosphor radiography
    • Blackwell, Berlin
    • Busch HP, Georgi M (1992) Digital radiography: clinical experience with digital image intensifier and storage phosphor radiography, Blackwell, Berlin
    • (1992)
    • Busch, H.P.1    Georgi, M.2
  • 12
    • 0028840132 scopus 로고
    • Radiation exposure of patients by using modern digital fluoroscopy systems
    • Kopp J, Maiter W, Losereit C (1995) Radiation exposure of patients by using modern digital fluoroscopy systems. Radiat Prot Dosim 57:487-488
    • (1995) Radiat. Prot. Dosim. , vol.57 , pp. 487-488
    • Kopp, J.1    Maiter, W.2    Losereit, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.