메뉴 건너뛰기




Volumn 17, Issue 2, 2003, Pages 145-146

Effect of humidity in the circuit on the CO2 absorption capacity of Amsorb and Sodasorb II

Author keywords

Amsorb; CO2 absorption capacity; Soda lime; Sodasorb II

Indexed keywords

CARBON DIOXIDE; DESFLURANE; SEVOFLURANE; SODIUM CARBONATE;

EID: 0037482000     PISSN: 09138668     EISSN: None     Source Type: Journal    
DOI: 10.1007/s005400300034     Document Type: Article
Times cited : (6)

References (8)
  • 2
    • 0034982062 scopus 로고    scopus 로고
    • Lack of degradation of sevoflurane by a new carbon dioxide absorbent in humans
    • Mchaourab A, Arain SR, Ebert TJ (2001) Lack of degradation of sevoflurane by a new carbon dioxide absorbent in humans. Anesthesiology 94:1007-1009
    • (2001) Anesthesiology , vol.94 , pp. 1007-1009
    • Mchaourab, A.1    Arain, S.R.2    Ebert, T.J.3
  • 3
    • 0034956001 scopus 로고    scopus 로고
    • The carbon dioxide absorption capacity of Amsorb is half that of soda lime
    • Higuchi H, Adachi Y, Arisuma S, Kanno M, Satoh T (2001) The carbon dioxide absorption capacity of Amsorb is half that of soda lime. Anesth Analg 93:221-225
    • (2001) Anesth. Analg. , vol.93 , pp. 221-225
    • Higuchi, H.1    Adachi, Y.2    Arisuma, S.3    Kanno, M.4    Satoh, T.5
  • 4
    • 0033636095 scopus 로고    scopus 로고
    • Warning: Carbon dioxide absorption capacity of Amsorb was unexpectedly low in low-flow anesthesia
    • Ueyama H, Takashina M, Suzuki T, Sriranganathan V, Mashimo T (2000) Warning: carbon dioxide absorption capacity of Amsorb was unexpectedly low in low-flow anesthesia. Anesthesiology 93:1560-1561
    • (2000) Anesthesiology , vol.93 , pp. 1560-1561
    • Ueyama, H.1    Takashina, M.2    Suzuki, T.3    Sriranganathan, V.4    Mashimo, T.5
  • 5
    • 0034983216 scopus 로고    scopus 로고
    • The in vitro performance of carbon dioxide absorbents with and without strong alkali
    • Bedi A, Gallagher AC, Fee JPH, Murray JM (2001) The in vitro performance of carbon dioxide absorbents with and without strong alkali. Anaesthesia 56:546-550
    • (2001) Anaesthesia , vol.56 , pp. 546-550
    • Bedi, A.1    Gallagher, A.C.2    Fee, J.P.H.3    Murray, J.M.4
  • 6
    • 0034115789 scopus 로고    scopus 로고
    • Absorbents differ enormously in their capacity to produce compound A and carbon monoxide
    • Stabernack CR, Brown R, Laster MJ, Dudziak R, Eger EI II (2000) Absorbents differ enormously in their capacity to produce compound A and carbon monoxide. Anesth Analg 90:1428-1435
    • (2000) Anesth. Analg. , vol.90 , pp. 1428-1435
    • Stabernack, C.R.1    Brown, R.2    Laster, M.J.3    Dudziak, R.4    Eger E.I. II5
  • 7
    • 0031962704 scopus 로고    scopus 로고
    • Effect of the water content of soda lime on compound A concentration in the anesthesia circuit in sevoflurane anesthesia
    • Bito H, Ikeuchi Y, Ikeda K (1998) Effect of the water content of soda lime on compound A concentration in the anesthesia circuit in sevoflurane anesthesia. Anesthesiology 88:66-71
    • (1998) Anesthesiology , vol.88 , pp. 66-71
    • Bito, H.1    Ikeuchi, Y.2    Ikeda, K.3
  • 8
    • 0030778222 scopus 로고    scopus 로고
    • Partly exhausted soda lime or soda lime with water added, inhibits the increase in compound A concentration in the circle system during low-flow sevoflurane anaesthesia
    • Moriwaki G, Bito H, Ikeda K (1997) Partly exhausted soda lime or soda lime with water added, inhibits the increase in compound A concentration in the circle system during low-flow sevoflurane anaesthesia. Br J Anaesth 79:782-786
    • (1997) Br. J. Anaesth. , vol.79 , pp. 782-786
    • Moriwaki, G.1    Bito, H.2    Ikeda, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.