-
2
-
-
0031926997
-
Monitoring the hepato-splanchnic region in the critically ill patient. Measurement techniques and clinical relevance
-
Brinkmann A., Calzia E., Trager K., Radermacher P. Monitoring the hepato-splanchnic region in the critically ill patient. Measurement techniques and clinical relevance. Intensive Care Med. 24:1998;542-556.
-
(1998)
Intensive Care Med.
, vol.24
, pp. 542-556
-
-
Brinkmann, A.1
Calzia, E.2
Trager, K.3
Radermacher, P.4
-
3
-
-
0027202192
-
Regional blood flow and oxygen transport in septic shock
-
Ruokonen E., Takala J., Kari A., Saxen H., Mertsola J., Hansen E.J. Regional blood flow and oxygen transport in septic shock. Crit. Care Med. 21:1993;1296-1303.
-
(1993)
Crit. Care Med.
, vol.21
, pp. 1296-1303
-
-
Ruokonen, E.1
Takala, J.2
Kari, A.3
Saxen, H.4
Mertsola, J.5
Hansen, E.J.6
-
4
-
-
0032953935
-
Predicting outcome after cardiac surgery: Comparison of global haemodynamic and tonometric variables
-
Bams J.L., Mariani M.A., Groeneveld A.B.J. Predicting outcome after cardiac surgery: comparison of global haemodynamic and tonometric variables. Br. J. Anaesth. 82:1999;33-37.
-
(1999)
Br. J. Anaesth.
, vol.82
, pp. 33-37
-
-
Bams, J.L.1
Mariani, M.A.2
Groeneveld, A.B.J.3
-
5
-
-
0033026495
-
Can gastric intramucosal pH (pHi) predict outcome of paediatric cardiac surgery?
-
Bichel T., Kalangos A., Rourge J.C. Can gastric intramucosal pH (pHi) predict outcome of paediatric cardiac surgery? Paediatr. Anaesth. 9:1999;129-134.
-
(1999)
Paediatr. Anaesth.
, vol.9
, pp. 129-134
-
-
Bichel, T.1
Kalangos, A.2
Rourge, J.C.3
-
6
-
-
0027962066
-
Intraluminal "balloonless" air tonometry: A new method for determination of gastrointestinal mucosal carbon dioxide tension
-
Salzman A.L., strong K.E., Wang H., Wollert P.S., Vandermeer T.J., Fink M.P. Intraluminal "balloonless" air tonometry: a new method for determination of gastrointestinal mucosal carbon dioxide tension. Crit. Care Med. 22:1994;126-134.
-
(1994)
Crit. Care Med.
, vol.22
, pp. 126-134
-
-
Salzman, A.L.1
Strong, K.E.2
Wang, H.3
Wollert, P.S.4
Vandermeer, T.J.5
Fink, M.P.6
-
8
-
-
45549110171
-
-
J.M. Lopez-Higuera (Ed.), Wiley, New York, Chapter 33
-
F. Baldini, A.G. Mignani, in: J.M. Lopez-Higuera (Ed.), Handbook of Optical Fibre Sensing Technology, Wiley, New York, 2002, Chapter 33, pp. 705-727.
-
(2002)
Handbook of Optical Fibre Sensing Technology
, pp. 705-727
-
-
Baldini, F.1
Mignani, A.G.2
-
9
-
-
2142744124
-
A carbon dioxide sensor based on fluorescence
-
Zhujun Z., Seitz W.R. A carbon dioxide sensor based on fluorescence. Anal. Chim. Acta. 160:1984;305-309.
-
(1984)
Anal. Chim. Acta
, vol.160
, pp. 305-309
-
-
Zhujun, Z.1
Seitz, W.R.2
-
12
-
-
0000869858
-
Fiber-optic sensing of carbon dioxide based on excited-state proton transfer to a luminescent ruthenium(II) complex
-
Orellana G., Moreno-Bondi M.C., Segovia E., Marazuela M.D. Fiber-optic sensing of carbon dioxide based on excited-state proton transfer to a luminescent ruthenium(II) complex. Anal. Chem. 64:1992;2210-2215.
-
(1992)
Anal. Chem.
, vol.64
, pp. 2210-2215
-
-
Orellana, G.1
Moreno-Bondi, M.C.2
Segovia, E.3
Marazuela, M.D.4
-
13
-
-
11944267513
-
Equilibrium studies on novel colorimetric plastic film sensors for carbon dioxide
-
Mills A., Chang Q., McMurray N. Equilibrium studies on novel colorimetric plastic film sensors for carbon dioxide. Anal. Chem. 64:1992;1383-1389.
-
(1992)
Anal. Chem.
, vol.64
, pp. 1383-1389
-
-
Mills, A.1
Chang, Q.2
McMurray, N.3
-
14
-
-
0000636562
-
Fluorescent plastic thin-film sensor for carbon dioxide
-
Mills A., Chang Q. Fluorescent plastic thin-film sensor for carbon dioxide. Analyst. 118:1993;839-843.
-
(1993)
Analyst
, vol.118
, pp. 839-843
-
-
Mills, A.1
Chang, Q.2
-
15
-
-
0029350635
-
Sensitivity studies on optical carbon dioxide sensors based on ion-pairing
-
Weigl B.H., Wolfbeis O.S. Sensitivity studies on optical carbon dioxide sensors based on ion-pairing. Sens. Actuators B: Chem. 28:1995;151-156.
-
(1995)
Sens. Actuators B: Chem.
, vol.28
, pp. 151-156
-
-
Weigl, B.H.1
Wolfbeis, O.S.2
-
16
-
-
0022559386
-
Optical fluorescence and its application to intravascular blood gas monitoring system
-
Gehrich J.L., Lübbers D.L., Opitz N., Hansmann D.R., Miller W.M., Tusa J.K., Yafuso M. Optical fluorescence and its application to intravascular blood gas monitoring system. IEEE Trans. Biomed. Eng. BME-33:1986;117-132.
-
(1986)
IEEE Trans. Biomed. Eng.
, vol.BME-33
, pp. 117-132
-
-
Gehrich, J.L.1
Lübbers, D.L.2
Opitz, N.3
Hansmann, D.R.4
Miller, W.M.5
Tusa, J.K.6
Yafuso, M.7
-
17
-
-
0023383324
-
Laser-fibre optic "optrode" for real time in-vivo blood carbon dioxide level monitoring
-
Hirschfeld T., Miller F., Thomas S., Miller H., Milanovich F., Gaver R.W. Laser-fibre optic "optrode" for real time in-vivo blood carbon dioxide level monitoring. J. Light. Tech. LT-5:1987;1027-1033.
-
(1987)
J. Light. Tech.
, vol.LT-5
, pp. 1027-1033
-
-
Hirschfeld, T.1
Miller, F.2
Thomas, S.3
Miller, H.4
Milanovich, F.5
Gaver, R.W.6
-
18
-
-
0031084102
-
Breath-by-breath measurement of carbon dioxide using a plastic film optical sensor
-
Mills A., Lepre A., Wild L. Breath-by-breath measurement of carbon dioxide using a plastic film optical sensor. Sens. Actuators B: Chem. 38-39:1997;419-425.
-
(1997)
Sens. Actuators B: Chem.
, vol.38-39
, pp. 419-425
-
-
Mills, A.1
Lepre, A.2
Wild, L.3
-
19
-
-
0012847208
-
-
2658 Patton Road, St. Paul, MN 55113, USA
-
Diametrics Medical Inc., 2658 Patton Road, St. Paul, MN 55113, USA, http://www.diametrics.com.
-
-
-
-
20
-
-
0012786358
-
-
P.O. Box #10395, Palo Alto, 94303 CA, USA
-
Agilent Technologies, P.O. Box #10395, Palo Alto, 94303 CA, USA, http://www.agilent.com.
-
-
-
-
21
-
-
0000293666
-
Capillary optical sensor
-
Weigl B.H., Wolfbeis O.S. Capillary optical sensor. Anal. Chem. 66:1994;3323-3327.
-
(1994)
Anal. Chem.
, vol.66
, pp. 3323-3327
-
-
Weigl, B.H.1
Wolfbeis, O.S.2
|