메뉴 건너뛰기




Volumn 104, Issue 2, 2003, Pages 121-126

A small probe with a gradient index lens for confocal measurement

Author keywords

Confocal microscopy; Gradient index lens; High resolution; Non contact measurement

Indexed keywords

MICROSCOPIC EXAMINATION; MONITORING; OPTICAL DESIGN; OPTICAL INSTRUMENT LENSES; REFRACTIVE INDEX; TRACKING (POSITION);

EID: 0037446189     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0924-4247(02)00438-7     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 0000407407 scopus 로고
    • The extend-focus, auto-focus and surface-profiling techniques of confocal microscopy
    • C.J.R. Sheppard, H.J. Matthews, The extend-focus, auto-focus and surface-profiling techniques of confocal microscopy, J. Mod. Opt. 35 (1) (1988) 145-154.
    • (1988) J. Mod. Opt. , vol.35 , Issue.1 , pp. 145-154
    • Sheppard, C.J.R.1    Matthews, H.J.2
  • 2
    • 0031079146 scopus 로고    scopus 로고
    • Noninterferometric differential confocal microscopy with 2-nm depth resolution
    • C.H. Lee, J.P. Wang, Noninterferometric differential confocal microscopy with 2-nm depth resolution, Opt. Commun. 35 (1997) 233-237.
    • (1997) Opt. Commun. , vol.35 , pp. 233-237
    • Lee, C.H.1    Wang, J.P.2
  • 3
    • 84985217555 scopus 로고
    • Three-dimensional imaging in confocal imaging systems with finite sized detectors
    • T. Wilson, A.R. Carlini, Three-dimensional imaging in confocal imaging systems with finite sized detectors, J. Microsc. 149 (1988) 51-56.
    • (1988) J. Microsc. , vol.149 , pp. 51-56
    • Wilson, T.1    Carlini, A.R.2
  • 4
    • 0000401673 scopus 로고
    • Depth response of scanning microscopes
    • T. Wilson, Depth response of scanning microscopes, Optik 81 (3) (1989) 113-118.
    • (1989) Optik , vol.81 , Issue.3 , pp. 113-118
    • Wilson, T.1
  • 5
    • 84975623995 scopus 로고
    • Depth response of confocal optical microscopes
    • T.R. Corle, C.-H. Chou, G.S. Kino, Depth response of confocal optical microscopes, Opt. Lett. 11 (12) (1986) 770-772.
    • (1986) Opt. Lett. , vol.11 , Issue.12 , pp. 770-772
    • Corle, T.R.1    Chou, C.-H.2    Kino, G.S.3
  • 6
    • 84975606536 scopus 로고
    • Size of the detector in confocal imaging systems
    • T. Wilson, A.R. Carlini, Size of the detector in confocal imaging systems, Opt. Lett. 12 (4) (1987) 227-229.
    • (1987) Opt. Lett. , vol.12 , Issue.4 , pp. 227-229
    • Wilson, T.1    Carlini, A.R.2
  • 7
    • 0001725322 scopus 로고
    • Effect of detector displacement in confocal imaging systems
    • T. Wilson, A.R. Carlini, Effect of detector displacement in confocal imaging systems, Appl. Opt. 27 (18) (1988) 3791-3799.
    • (1988) Appl. Opt. , vol.27 , Issue.18 , pp. 3791-3799
    • Wilson, T.1    Carlini, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.