Volumn 44, Issue 13, 2003, Pages 2073-2091

Performance characteristics of counter flow wet cooling towers

Author keywords

Cooling towers; Model; Performance evaluation

Indexed keywords

EVAPORATION; HEAT CONVECTION; MASS TRANSFER; POLYVINYL CHLORIDES;

EID: 0037411692     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0196-8904(02)00231-5     Document Type: Article
Times cited : (100)

References (19)
  • 3
    • 0000882020 scopus 로고
    • A unified theoretical treatment for thermal analysis of cooling towers, evaporative condensers, and fluid coolers
    • Webb R.L. A unified theoretical treatment for thermal analysis of cooling towers, evaporative condensers, and fluid coolers. ASHRAE Trans. 90(2):1984;398-415.
    • (1984) ASHRAE Trans. , vol.90 , Issue.2 , pp. 398-415
    • Webb, R.L.1
  • 4
    • 0000882021 scopus 로고
    • Algorithms for performance simulation of cooling towers, evaporative condensers, and fluid coolers
    • Webb R.L., Villacres A. Algorithms for performance simulation of cooling towers, evaporative condensers, and fluid coolers. ASHRAE Trans. 90(2):1984;416-458.
    • (1984) ASHRAE Trans. , vol.90 , Issue.2 , pp. 416-458
    • Webb, R.L.1    Villacres, A.2
  • 5
    • 85000281909 scopus 로고
    • Design of cooling towers by the effectiveness-NTU method
    • Jaber H., Webb R.L. Design of cooling towers by the effectiveness-NTU method. ASME J. Heat Transf. 111(4):1989;837-843.
    • (1989) ASME J. Heat Transf. , vol.111 , Issue.4 , pp. 837-843
    • Jaber, H.1    Webb, R.L.2
  • 6
    • 0000957106 scopus 로고
    • Effectiveness models for cooling towers and cooling coils
    • Braun J.E., Klein S.A., Mitchell J.W. Effectiveness models for cooling towers and cooling coils. ASHRAE Trans. 95(2):1989;164-174.
    • (1989) ASHRAE Trans. , vol.95 , Issue.2 , pp. 164-174
    • Braun, J.E.1    Klein, S.A.2    Mitchell, J.W.3
  • 8
    • 0033742928 scopus 로고    scopus 로고
    • Thermal behavior of closed wet cooling towers for use with chilled ceilings
    • Jorge F., Armando C.O. Thermal behavior of closed wet cooling towers for use with chilled ceilings. Appl. Therm. Eng. 20:2000;1225-1236.
    • (2000) Appl. Therm. Eng. , vol.20 , pp. 1225-1236
    • Jorge, F.1    Armando, C.O.2
  • 9
    • 0028727461 scopus 로고
    • Cooling tower performance: Theory and experiments
    • Bernier M.A. Cooling tower performance: theory and experiments. ASHRAE Trans. 100(2):1994;114-121.
    • (1994) ASHRAE Trans. , vol.100 , Issue.2 , pp. 114-121
    • Bernier, M.A.1
  • 10
    • 0029292804 scopus 로고
    • Thermal performance of cooling towers
    • Bernier M.A. Thermal performance of cooling towers. ASHRAE J. 37(4):1995;56-61.
    • (1995) ASHRAE J. , vol.37 , Issue.4 , pp. 56-61
    • Bernier, M.A.1
  • 11
    • 0032627681 scopus 로고    scopus 로고
    • Modeling the dynamic thermal behavior of cooling towers containing packing materials
    • Nimr M.A. Modeling the dynamic thermal behavior of cooling towers containing packing materials. Heat Transf. Eng. 20(1):1999;91-96.
    • (1999) Heat Transf. Eng. , vol.20 , Issue.1 , pp. 91-96
    • Nimr, M.A.1
  • 12
    • 0036493444 scopus 로고    scopus 로고
    • The use of thermo-fluid dynamic efficiency in cooling towers
    • Jose A.S. The use of thermo-fluid dynamic efficiency in cooling towers. Heat Transf. Eng. 23:2002;22-30.
    • (2002) Heat Transf. Eng. , vol.23 , pp. 22-30
    • Jose, A.S.1
  • 14
    • 0020934065 scopus 로고
    • Formulations for the thermodynamic properties of dry air from 173.15 to 473.15 K, and of saturated moist air from 173.15 to 372.15 K, at pressure to 5 MPa
    • Hyland R.W., Wexler A. Formulations for the thermodynamic properties of dry air from 173.15 to 473.15 K, and of saturated moist air from 173.15 to 372.15 K, at pressure to 5 MPa. ASHRAE Trans. 89(2):1983;520-535.
    • (1983) ASHRAE Trans. , vol.89 , Issue.2 , pp. 520-535
    • Hyland, R.W.1    Wexler, A.2
  • 16
    • 0035413344 scopus 로고    scopus 로고
    • An improved design and rating analyses of counter flow wet cooling towers
    • Khan J.R., Zubair S.M. An improved design and rating analyses of counter flow wet cooling towers. ASME J Heat Transf. 123:2001;770-778.
    • (2001) ASME J Heat Transf , vol.123 , pp. 770-778
    • Khan, J.R.1    Zubair, S.M.2
  • 17
    • 0003474886 scopus 로고
    • Atlanta, GA: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Chapter 6
    • ASHRAE handbook of fundamentals. 1993;American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc, Atlanta, GA. Chapter 6.
    • (1993) ASHRAE Handbook of Fundamentals
  • 18
    • 0004085882 scopus 로고
    • Atlanta, GA: American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. [chapter 3]
    • ASHRAE equipment guide. 1983;American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc, Atlanta, GA. [chapter 3].
    • (1983) ASHRAE Equipment Guide
  • 19
    • 0001171952 scopus 로고
    • Performance of small mechanical draft cooling towers
    • Simpson W.M., Sherwood T.K. Performance of small mechanical draft cooling towers. Refrig. Eng. 52(6):1946;525-543. 574-6.
    • (1946) Refrig. Eng. , vol.52 , Issue.6 , pp. 525-543
    • Simpson, W.M.1    Sherwood, T.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.