Volumn 44, Issue 11, 2003, Pages 1831-1843

Climatic effects on cooling load determination in subtropical regions

Author keywords

Building envelope; Computer simulation; Cooling load; Design weather conditions; Significant level

Indexed keywords

AIR CONDITIONING; ARCHITECTURAL DESIGN; CLIMATE CONTROL; COMPUTER SIMULATION; COOLING; HEATING; VENTILATION;

EID: 0037411416     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0196-8904(02)00189-9     Document Type: Article
Times cited : (33)

References (19)
  • 1
    • 0013069126 scopus 로고
    • Typical weather year for building energy simulation in Hong Kong
    • Lam J.C., Hui S.C.M., Yuen R.K.K. Typical weather year for building energy simulation in Hong Kong. Hong Kong Meteorol. Soc. Bull. 2(1):1992;36-44.
    • (1992) Hong Kong Meteorol. Soc. Bull. , vol.2 , Issue.1 , pp. 36-44
    • Lam, J.C.1    Hui, S.C.M.2    Yuen, R.K.K.3
  • 2
    • 0029751163 scopus 로고    scopus 로고
    • Sensitivity analysis of energy performance of office buildings
    • Lam J.C., Hui S.C.M. Sensitivity analysis of energy performance of office buildings. Build. Environ. 31(1):1996;27-39.
    • (1996) Build. Environ. , vol.31 , Issue.1 , pp. 27-39
    • Lam, J.C.1    Hui, S.C.M.2
  • 3
    • 0003500116 scopus 로고
    • Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • ASHRAE handbook - fundamentals. 1993;American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA.
    • (1993) ASHRAE Handbook - Fundamentals
  • 4
    • 0029277136 scopus 로고
    • Outdoor design conditions for HVAC system design and energy estimation for buildings in Hong Kong
    • Lam J.C., Hui S.C.M. Outdoor design conditions for HVAC system design and energy estimation for buildings in Hong Kong. Energy Build. 22(1):1995;25-43.
    • (1995) Energy Build. , vol.22 , Issue.1 , pp. 25-43
    • Lam, J.C.1    Hui, S.C.M.2
  • 5
    • 0002974556 scopus 로고    scopus 로고
    • Chiller plant sizing by cooling load simulation as a means to avoid oversized plant
    • Yik F.W.H., Lee W.L., Burnett J., Jones P. Chiller plant sizing by cooling load simulation as a means to avoid oversized plant. Hong Kong Trans. 6(2):1998;19-25.
    • (1998) Hong Kong Trans. , vol.6 , Issue.2 , pp. 19-25
    • Yik, F.W.H.1    Lee, W.L.2    Burnett, J.3    Jones, P.4
  • 6
    • 0021897007 scopus 로고
    • Analysis of energy conservation standards for Singapore office buildings
    • Turiel I., Curtis R., Levine M.D. Analysis of energy conservation standards for Singapore office buildings. Energy. 10(1):1985;95-107.
    • (1985) Energy , vol.10 , Issue.1 , pp. 95-107
    • Turiel, I.1    Curtis, R.2    Levine, M.D.3
  • 7
    • 0024065887 scopus 로고
    • A simplified overall thermal transfer value equation for building envelopes
    • Chou S.K., Lee Y.K. A simplified overall thermal transfer value equation for building envelopes. Energy. 13(8):1988;657-670.
    • (1988) Energy , vol.13 , Issue.8 , pp. 657-670
    • Chou, S.K.1    Lee, Y.K.2
  • 8
    • 0013123123 scopus 로고
    • Lawrence Berkeley Laboratory, University of California, California
    • DOE-2 Supplement Version 2.1E LBL-34947, Lawrence Berkeley Laboratory, University of California, California, 1993.
    • (1993) DOE-2 Supplement Version 2.1E LBL-34947
  • 10
    • 0028383520 scopus 로고
    • A survey of building envelop designs for commercial building in Hong Kong
    • Lam J.C., Goodsall C.J. A survey of building envelop designs for commercial building in Hong Kong. Build. Res. Inf. 22(2):1994;79-86.
    • (1994) Build. Res. Inf. , vol.22 , Issue.2 , pp. 79-86
    • Lam, J.C.1    Goodsall, C.J.2
  • 11
    • 0003120444 scopus 로고
    • Hong Kong Observatory, Hong Kong, annual publications
    • Surface Observations in Hong Kong, Hong Kong Observatory, Hong Kong, 1979-2000, annual publications.
    • (1979) Surface Observations in Hong Kong
  • 12
    • 0013119818 scopus 로고
    • Technical Note no. 81, Royal Observatory Hong Kong, Hong Kong
    • Lau SY. Global Solar Radiation in Hong Kong, Technical Note no. 81, Royal Observatory Hong Kong, Hong Kong, 1989.
    • (1989) Global Solar Radiation in Hong Kong
    • Lau, S.Y.1
  • 13
    • 0036496559 scopus 로고    scopus 로고
    • A study of solar radiation daylight illuminance and sky luminance data measurements for Hong Kong
    • Li D.H.W., Lam J.C., Lau C.C.S. A study of solar radiation daylight illuminance and sky luminance data measurements for Hong Kong. Architect. Sci. Rev. 45(1):2002;21-30.
    • (2002) Architect. Sci. Rev. , vol.45 , Issue.1 , pp. 21-30
    • Li, D.H.W.1    Lam, J.C.2    Lau, C.C.S.3
  • 14
    • 0033099605 scopus 로고    scopus 로고
    • An analysis of climatic variables and design implications
    • Li D.H.W., Lam J.C. An analysis of climatic variables and design implications. Architect. Sci. Rev. 42(1):1999;15-25.
    • (1999) Architect. Sci. Rev. , vol.42 , Issue.1 , pp. 15-25
    • Li, D.H.W.1    Lam, J.C.2
  • 16
    • 0001843105 scopus 로고
    • Test reference year for comparative energy study
    • Hui S.C.M., Lam J.C. Test reference year for comparative energy study. Hong Kong Engineer. 20(2):1992;13-16.
    • (1992) Hong Kong Engineer , vol.20 , Issue.2 , pp. 13-16
    • Hui, S.C.M.1    Lam, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.