메뉴 건너뛰기




Volumn 35, Issue 4, 2003, Pages 375-382

Development of an integrated dynamic thermal bridging assessment environment

Author keywords

Built environment; Energy; Numerical modeling; Simulation; Thermal bridging; Validation

Indexed keywords

BOUNDARY CONDITIONS; BUILDINGS; COMPUTER SIMULATION; CONDENSATION; FUNGI; MATHEMATICAL MODELS; ONLINE SYSTEMS; USER INTERFACES;

EID: 0037401717     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0378-7788(02)00106-8     Document Type: Article
Times cited : (18)

References (27)
  • 1
    • 0028464224 scopus 로고
    • Influence of architectural details on the overall thermal performance of residential wall systems
    • Kosny J., Desjarlais A.O. Influence of architectural details on the overall thermal performance of residential wall systems. Journal of Thermal Insulation and Building Envelopes. 18:1994;53-69.
    • (1994) Journal of Thermal Insulation and Building Envelopes , vol.18 , pp. 53-69
    • Kosny, J.1    Desjarlais, A.O.2
  • 2
    • 0030108906 scopus 로고    scopus 로고
    • Thermal performance and wall ratings
    • Christian J.E., Kosny J. Thermal performance and wall ratings. ASHRAE Journal. 38(3):1996;56-65.
    • (1996) ASHRAE Journal , vol.38 , Issue.3 , pp. 56-65
    • Christian, J.E.1    Kosny, J.2
  • 4
    • 0030709927 scopus 로고    scopus 로고
    • Calculation methods and insulation techniques for steel stud walls in low-rise multifamily housing
    • Tuluca A.N., Lahiri D., Zaidi J.H. Calculation methods and insulation techniques for steel stud walls in low-rise multifamily housing. ASHRAE Transactions. 103(1):1997;550-562.
    • (1997) ASHRAE Transactions , vol.103 , Issue.1 , pp. 550-562
    • Tuluca, A.N.1    Lahiri, D.2    Zaidi, J.H.3
  • 5
    • 0031636439 scopus 로고    scopus 로고
    • The significance of bolts in the thermal performance of curtain-wall frames for glazed facades
    • Griffith B., Finlayson E., Yazdanian M., Arasteh D. The significance of bolts in the thermal performance of curtain-wall frames for glazed facades. ASHRAE Transactions. 104(1):1998;1063-1069.
    • (1998) ASHRAE Transactions , vol.104 , Issue.1 , pp. 1063-1069
    • Griffith, B.1    Finlayson, E.2    Yazdanian, M.3    Arasteh, D.4
  • 6
    • 0034826149 scopus 로고    scopus 로고
    • Advances in residential wall technologies - Simple ways of decreasing the whole building energy consumption
    • Kosny J. Advances in residential wall technologies - simple ways of decreasing the whole building energy consumption. ASHRAE Transactions. 107(1):2001;421-432.
    • (2001) ASHRAE Transactions , vol.107 , Issue.1 , pp. 421-432
    • Kosny, J.1
  • 8
  • 10
    • 0027684353 scopus 로고
    • Assessing building performance by simulation
    • Clarke J.A. Assessing building performance by simulation. Building and Environment. 28(4):1993;419-427.
    • (1993) Building and Environment , vol.28 , Issue.4 , pp. 419-427
    • Clarke, J.A.1
  • 12
    • 0024608778 scopus 로고
    • Transfer functions for efficient calculation of multi-dimensional transient heat transfer
    • Seem J.E., Klein S.A., Beckman W.A., Mitchell J.W. Transfer functions for efficient calculation of multi-dimensional transient heat transfer. Journal of Heat Transfer. 111(5):1989;264-273.
    • (1989) Journal of Heat Transfer , vol.111 , Issue.5 , pp. 264-273
    • Seem, J.E.1    Klein, S.A.2    Beckman, W.A.3    Mitchell, J.W.4
  • 14
    • 0032314232 scopus 로고    scopus 로고
    • Performance check between whole building thermal performance criteria and exterior wall measured clear wall R-value, thermal bridging, thermal mass and air-tightness
    • Kosny J., Christian J.E., Desjarlais A.O., Kossecka E., Berrenberg L. Performance check between whole building thermal performance criteria and exterior wall measured clear wall R-value, thermal bridging, thermal mass and air-tightness. ASHRAE Transactions. 104(4):1998;1379-1389.
    • (1998) ASHRAE Transactions , vol.104 , Issue.4 , pp. 1379-1389
    • Kosny, J.1    Christian, J.E.2    Desjarlais, A.O.3    Kossecka, E.4    Berrenberg, L.5
  • 15
    • 0012647687 scopus 로고    scopus 로고
    • Modeling 2D and 3D heat transfer through composite wall and roof assemblies in hourly simulation programs
    • S. Kemp, Modeling 2D and 3D heat transfer through composite wall and roof assemblies in hourly simulation programs, ASHRAE final report 1145, 2001.
    • (2001) ASHRAE Final Report , vol.1145
    • Kemp, S.1
  • 16
    • 0036604734 scopus 로고    scopus 로고
    • Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programs
    • Kosny J., Kossecka E. Multi-dimensional heat transfer through complex building envelope assemblies in hourly energy simulation programs. Energy and Buildings. 34:2002;445-454.
    • (2002) Energy and Buildings , vol.34 , pp. 445-454
    • Kosny, J.1    Kossecka, E.2
  • 17
    • 0034818296 scopus 로고    scopus 로고
    • Building environment simulation before desk top computers in the USA through a personal memory
    • Kusuda T. Building environment simulation before desk top computers in the USA through a personal memory. Energy and Buildings. 33:2001;291-302.
    • (2001) Energy and Buildings , vol.33 , pp. 291-302
    • Kusuda, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.