Steady-state moisture diffusion in curved walls, in the absence of condensate flow, via the BEM: A practical Civil Engineering approach (Glaser method)

Author keywords

Boundary Element Method; Condensation; Heat transfer; Moisture diffusion; Temperature; Vapour pressure

Indexed keywords

BOUNDARY ELEMENT METHOD; BUILDING CODES; CONDENSATION; DIFFUSION; MOISTURE;

EID: 0037400759     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-1323(02)00208-1     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 0000574060 scopus 로고
    • Vereinfachte Berechnung der Dampfdiffusion durch geschichtete Wände bei Ausscheidung von Wasser und Eis
    • 386-90
    • Glaser H. Vereinfachte Berechnung der Dampfdiffusion durch geschichtete Wände bei Ausscheidung von Wasser und Eis, Kältetechnik 1958; 10 (11):358-64 and (12):386-90.
    • (1958) Kältetechnik , vol.10 , Issue.11-12 , pp. 358-364
    • Glaser, H.1
  • 3
    • 0016441605 scopus 로고
    • Systems of differential equations of heat and mass transfer in capillary-porous bodies
    • Luikov AV. Systems of differential equations of heat and mass transfer in capillary-porous bodies. International Journal of Heat and Mass Transfer 1975;18:1-4.
    • (1975) International Journal of Heat and Mass Transfer , vol.18 , pp. 1-4
    • Luikov, A.V.1
  • 5
    • 85031211333 scopus 로고
    • DIN 4108 - Wärmeschutz im Hochbau. DIN Deutsches Institut für Normung
    • DIN 4108 - Wärmeschutz im Hochbau. DIN Deutsches Institut für Normung, 1981.
    • (1981)
  • 6
    • 84946046734 scopus 로고    scopus 로고
    • prEN ISO 13788 - Hygrothermal performance of building components and building elements
    • GTR WI 46 and CEN/TC 89 WI29. Calculation methods. The International Organization for Standardization and European Committee for Standardization
    • GTR WI 46 and CEN/TC 89 WI29. prEN ISO 13788 - Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods. The International Organization for Standardization and European Committee for Standardization, 1999.
    • (1999) Internal Surface Temperature to Avoid Critical Surface Humidity and Interstitial Condensation
  • 8
    • 0030088248 scopus 로고    scopus 로고
    • Moisture migration in building walls. Analysis of the interface phenomena
    • Freitas VP, Abrantes V, Crausse P. Moisture migration in building walls. Analysis of the interface phenomena. Building and Environment 1996;31(2):99-108.
    • (1996) Building and Environment , vol.31 , Issue.2 , pp. 99-108
    • Freitas, V.P.1    Abrantes, V.2    Crausse, P.3
  • 9
    • 0031231030 scopus 로고    scopus 로고
    • Numerical simulation of thermal performance of a square column
    • Mingfang T, Qigao C. Numerical simulation of thermal performance of a square column. Building and Environment 1997;32(5):411-5.
    • (1997) Building and Environment , vol.32 , Issue.5 , pp. 411-415
    • Mingfang, T.1    Qigao, C.2
  • 10
    • 0033736992 scopus 로고    scopus 로고
    • Exact boundary element integrations for two-dimensional Laplace equation
    • Fratantonio M, Rencis JJ. Exact boundary element integrations for two-dimensional Laplace equation. Engineering Analysis with Boundary Elements 2000;24(4):325-42.
    • (2000) Engineering Analysis With Boundary Elements , vol.24 , Issue.4 , pp. 325-342
    • Fratantonio, M.1    Rencis, J.J.2
  • 11
    • 0030358878 scopus 로고    scopus 로고
    • A generalized boundary integral equation for isotropic heat conduction with spatially varying thermal conductivity
    • Kassab AJ, Divo E. A generalized boundary integral equation for isotropic heat conduction with spatially varying thermal conductivity. Engineering Analysis with Boundary Elements 1996;18(4): 273-86.
    • (1996) Engineering Analysis With Boundary Elements , vol.18 , Issue.4 , pp. 273-286
    • Kassab, A.J.1    Divo, E.2
  • 12
    • 0030234075 scopus 로고    scopus 로고
    • Steady-state heat conduction analysis by improved multiple-reciprocity Boundary Element Method
    • Ochiai Y, Sekiya T. Steady-state heat conduction analysis by improved multiple-reciprocity Boundary Element Method. Engineering Analysis with Boundary Elements 1996;18(2):111-7.
    • (1996) Engineering Analysis With Boundary Elements , vol.18 , Issue.2 , pp. 111-117
    • Ochiai, Y.1    Sekiya, T.2
  • 13
    • 0034204051 scopus 로고    scopus 로고
    • An alternative construction of Green's function for the two-dimensional heat conduction
    • Melnikov YA. An alternative construction of Green's function for the two-dimensional heat conduction. Engineering Analysis with Boundary Elements 2000;24(6):467-75.
    • (2000) Engineering Analysis With Boundary Elements , vol.24 , Issue.6 , pp. 467-475
    • Melnikov, Y.A.1
  • 16
    • 85031233825 scopus 로고
    • British Standard code of practice for control of condensation in buildings - BS 5250. British Standards Institute, UK
    • British Standard code of practice for control of condensation in buildings - BS 5250. British Standards Institute, UK, 1989.
    • (1989)
  • 19
  • 20
    • 0042699183 scopus 로고
    • Calculation of potential flow about arbitrary bodies
    • Kucheman D, editor. New York: Pergamon
    • Hess JL, Smith AM. Calculation of potential flow about arbitrary bodies. In: Kucheman D, editor. Progress in Aeronautical Science, vol. 8. New York: Pergamon, 1967. p. 1-138.
    • (1967) Progress in Aeronautical Science , vol.8 , pp. 1-138
    • Hess, J.L.1    Smith, A.M.2
  • 21
    • 84886677955 scopus 로고
    • Simultaneous heat and moisture transport in building components
    • Frauhnofer-Informationzentrum Raum und Bau. Stuttgart: IRB-Verlag
    • Künzel HM. Simultaneous heat and moisture transport in building components. One and two-dimensional calculation using simple parameters. Frauhnofer-Informationzentrum Raum und Bau. Stuttgart: IRB-Verlag, 1995.
    • (1995) One and Two-dimensional Calculation Using Simple Parameters
    • Künzel, H.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.