메뉴 건너뛰기




Volumn 25, Issue 3, 2003, Pages 213-220

Data representation for joint kinematics simulation of the lower limb within an educational context

Author keywords

3D; Computer graphics; Human motion; Joint kinematics; Simulation

Indexed keywords

BIOMECHANICS; COMPUTER GRAPHICS; COMPUTER SIMULATION; KINEMATICS; MEDICAL IMAGING;

EID: 0037393068     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(02)00183-2     Document Type: Article
Times cited : (17)

References (19)
  • 2
    • 0023360112 scopus 로고
    • A system for three-dimensional interactive simulation of hand biomechanics
    • Buford W.L., Thompson D.E. A system for three-dimensional interactive simulation of hand biomechanics. IEEE Trans Biomed Eng. BME-34:1987;444-453.
    • (1987) IEEE Trans Biomed Eng , vol.BME-34 , pp. 444-453
    • Buford, W.L.1    Thompson, D.E.2
  • 3
    • 0025470348 scopus 로고
    • An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
    • Delp S.L., Loan J.P., Hoy M.G., Zajac F.E., Topp E.L., Rosen J.M. An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans Biomed Eng. 37:1990;757-767.
    • (1990) IEEE Trans Biomed Eng , vol.37 , pp. 757-767
    • Delp, S.L.1    Loan, J.P.2    Hoy, M.G.3    Zajac, F.E.4    Topp, E.L.5    Rosen, J.M.6
  • 4
    • 0029679795 scopus 로고    scopus 로고
    • New method of studying joint kinematics from three-dimensional reconstruction of MRI data
    • Hirsch B.E., Udupa J.K., Samarasekera S. New method of studying joint kinematics from three-dimensional reconstruction of MRI data. J Am Podiatric Med Assoc. 86:1996;4-15.
    • (1996) J Am Podiatric Med Assoc , vol.86 , pp. 4-15
    • Hirsch, B.E.1    Udupa, J.K.2    Samarasekera, S.3
  • 7
    • 0027223342 scopus 로고
    • Measurement of carpal bone geometry by computer analysis of three-dimensional CT images
    • Viegas S.F., Hillman G.R., Elder K.W., Stoner D.M., Patterson R.M. Measurement of carpal bone geometry by computer analysis of three-dimensional CT images. J Hand Surg. 18A:1993;341-349.
    • (1993) J Hand Surg , vol.18 A , pp. 341-349
    • Viegas, S.F.1    Hillman, G.R.2    Elder, K.W.3    Stoner, D.M.4    Patterson, R.M.5
  • 8
    • 4243962015 scopus 로고    scopus 로고
    • A mathematical description of three-dimensional joint kinematics using a noninvasive imaging technique
    • P.A. Smith, & G.F. Harris. New York: IEEE Press
    • Wynarsky G., Harris G.F. A mathematical description of three-dimensional joint kinematics using a noninvasive imaging technique. Smith P.A., Harris G.F. Human motion analysis. 1996;167-186 IEEE Press, New York.
    • (1996) Human motion analysis , pp. 167-186
    • Wynarsky, G.1    Harris, G.F.2
  • 10
    • 0021844595 scopus 로고
    • Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics
    • Woltring H.J., Huiskes R., de Lange A., Veldpaus F.E. Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech. 18:1985;379-389.
    • (1985) J Biomech , vol.18 , pp. 379-389
    • Woltring, H.J.1    Huiskes, R.2    De Lange, A.3    Veldpaus, F.E.4
  • 11
    • 0029311073 scopus 로고
    • Position and orientation of bones during movement anatomical frame definition and determination
    • Cappozzo A., Catani F., Della Croce U., Leardini A. Position and orientation of bones during movement anatomical frame definition and determination. Clin Biomech. 10:(4):1995;171-178.
    • (1995) Clin Biomech , vol.10 , Issue.4 , pp. 171-178
    • Cappozzo, A.1    Catani, F.2    Della Croce, U.3    Leardini, A.4
  • 14
    • 0030263449 scopus 로고    scopus 로고
    • Efficient technique for circle detection using hypothesis filtering and Hough transform
    • Lam W.C.Y., Yuen S.Y. Efficient technique for circle detection using hypothesis filtering and Hough transform. IEE Proc-Vis Image Signal Process. 43:(5):1996;292-300.
    • (1996) IEE Proc-Vis Image Signal Process , vol.43 , Issue.5 , pp. 292-300
    • Lam, W.C.Y.1    Yuen, S.Y.2
  • 15
    • 0029310701 scopus 로고
    • A procedure for determining rigid body transformation parameters
    • Challis J.H. A procedure for determining rigid body transformation parameters. J Biomech. 26:1995;733-737.
    • (1995) J Biomech , vol.26 , pp. 733-737
    • Challis, J.H.1
  • 16
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S., Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomed Eng. 105:1983;136-144.
    • (1983) J Biomed Eng , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 17
    • 0019159246 scopus 로고
    • Justification of triaxial goniometer for the measurement of joint rotation
    • Chao E.Y.S. Justification of triaxial goniometer for the measurement of joint rotation. J Biomech. 13:1980;989-1006.
    • (1980) J Biomech , vol.13 , pp. 989-1006
    • Chao, E.Y.S.1
  • 18
    • 0025696481 scopus 로고
    • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee
    • Pennock G.R., Clark K.J. An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. J Biomech. 23:1990;1209-1218.
    • (1990) J Biomech , vol.23 , pp. 1209-1218
    • Pennock, G.R.1    Clark, K.J.2
  • 19
    • 0028944091 scopus 로고
    • A graphics-based software system to develop and analyse models of musculoskeletal structures
    • Delp S.L., Loan J.P. A graphics-based software system to develop and analyse models of musculoskeletal structures. Comput Biol Med. 25:(1):1995;21-34.
    • (1995) Comput Biol Med , vol.25 , Issue.1 , pp. 21-34
    • Delp, S.L.1    Loan, J.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.