메뉴 건너뛰기




Volumn 90, Issue 4, 2003, Pages 520-522

Incidental detection of paradoxical air embolism with a transoesophageal Doppler probe inserted for measuring descending aortic blood flow

Author keywords

Complications, embolism; Embolism, air; Measurement techniques, transoesophageal Doppler ultrasonography; Monitoring, ultrasound

Indexed keywords

LISINOPRIL; NEUROMUSCULAR BLOCKING AGENT; ROCURONIUM; SEVOFLURANE; SUFENTANIL; THIOPENTAL;

EID: 0037385461     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/aeg090     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0028085241 scopus 로고
    • Venous and paradoxical air embolism in the sitting position. A prospective study with transoesophageal echocardiography
    • Papadopoulos S, Kuhly P, Brock M, Rudolph KH, Link J, Eyrich K. Venous and paradoxical air embolism in the sitting position. A prospective study with transoesophageal echocardiography. Acta Neurochir 1994; 126: 140-3
    • (1994) Acta Neurochir. , vol.126 , pp. 140-143
    • Papadopoulos, S.1    Kuhly, P.2    Brock, M.3    Rudolph, K.H.4    Link, J.5    Eyrich, K.6
  • 2
    • 0023690475 scopus 로고
    • Outcome following posterior fossa craniectomy in the sitting vs. horizontal positions
    • Black S, Ockert DB, Oliver WC, Cucchiara RF. Outcome following posterior fossa craniectomy in the sitting vs. horizontal positions. Anesthesiology 1988; 69: 49-56
    • (1988) Anesthesiology , vol.69 , pp. 49-56
    • Black, S.1    Ockert, D.B.2    Oliver, W.C.3    Cucchiara, R.F.4
  • 3
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984; 59: 17-20
    • (1984) Mayo Clin. Proc. , vol.59 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 4
    • 0024424166 scopus 로고
    • Failure of preoperative echo testing to prevent paradoxical air embolism: Report of two cases
    • Cucchiara RF, Nishimura RA, Black S. Failure of preoperative echo testing to prevent paradoxical air embolism: report of two cases. Anesthesiology 1989; 71: 604-7
    • (1989) Anesthesiology , vol.71 , pp. 604-607
    • Cucchiara, R.F.1    Nishimura, R.A.2    Black, S.3
  • 5
    • 0028221994 scopus 로고
    • Paradoxic air embolism during venous air embolism: Transesophageal echocardiographic evidence of transpulmonary air passage
    • Bedell EA, Berge KH, Losasso TJ. Paradoxic air embolism during venous air embolism: transesophageal echocardiographic evidence of transpulmonary air passage. Anesthesiology 1994; 80: 947-50
    • (1994) Anesthesiology , vol.80 , pp. 947-950
    • Bedell, E.A.1    Berge, K.H.2    Losasso, T.J.3
  • 6
    • 0031860910 scopus 로고    scopus 로고
    • Incidence of venous and paradoxical air embolism in neurosurgical patients in the sitting position: Detection by transesophageal echocardiography
    • Mammoto T, Hayashi Y, Ohnishi Y, Kuro M. Incidence of venous and paradoxical air embolism in neurosurgical patients in the sitting position: detection by transesophageal echocardiography. Acta Anaesthesiol Scand 1998; 42: 643-7
    • (1998) Acta Anaesthesiol. Scand. , vol.42 , pp. 643-647
    • Mammoto, T.1    Hayashi, Y.2    Ohnishi, Y.3    Kuro, M.4
  • 7
    • 0034072759 scopus 로고    scopus 로고
    • Neurologic manifestations of cerebral air embolism as a complication of central venous catheterization
    • Heckman JG, Lang CJG, Kindler K, Huk W, Erbguth FJ, Neundörfer B. Neurologic manifestations of cerebral air embolism as a complication of central venous catheterization. Crit Care Med 2000; 28: 1621-5
    • (2000) Crit. Care Med. , vol.28 , pp. 1621-1625
    • Heckman, J.G.1    Lang, C.J.G.2    Kindler, K.3    Huk, W.4    Erbguth, F.J.5    Neundörfer, B.6
  • 10
    • 0025257050 scopus 로고
    • Preoperative and intraoperative echocardiography to detect right-to-left shunt in patients undergoing neurosurgical procedures in the sitting position
    • Black S, Muzzi DA, Nishimura RA, Cucchiara RF. Preoperative and intraoperative echocardiography to detect right-to-left shunt in patients undergoing neurosurgical procedures in the sitting position. Anesthesiology 1990; 72: 436-8
    • (1990) Anesthesiology , vol.72 , pp. 436-438
    • Black, S.1    Muzzi, D.A.2    Nishimura, R.A.3    Cucchiara, R.F.4
  • 11
    • 0023895824 scopus 로고
    • Prevalence of patent foramen ovale in patients with stroke
    • Lechat Ph, Mas JL, Lascault G, et al. Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988; 318: 1148-52
    • (1988) N. Engl. J. Med. , vol.318 , pp. 1148-1152
    • Lechat, Ph.1    Mas, J.L.2    Lascault, G.3
  • 12
    • 0030786384 scopus 로고    scopus 로고
    • Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts
    • Horner S, Ni XS, Weihs W, et al. Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts. J Neurol Sci 1997; 150: 49-57
    • (1997) J. Neurol. Sci. , vol.150 , pp. 49-57
    • Horner, S.1    Ni, X.S.2    Weihs, W.3
  • 13
    • 0033775154 scopus 로고    scopus 로고
    • Transcranial doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position
    • Stendel R, Gramm H-J, Schröder K, Lober C, Brock M. Transcranial doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position. Anesthesiology 2000; 93: 971-5
    • (2000) Anesthesiology , vol.93 , pp. 971-975
    • Stendel, R.1    Gramm, H.-J.2    Schröder, K.3    Lober, C.4    Brock, M.5
  • 14
    • 0033943574 scopus 로고    scopus 로고
    • Contrast transcranial doppler ultrasound in the detection of right-to-left shunts. Time window and threshold in microbubble numbers
    • Droste DW, Silling K, Stypmann J, et al. Contrast transcranial doppler ultrasound in the detection of right-to-left shunts. Time window and threshold in microbubble numbers. Stroke 2000; 31: 1640-5
    • (2000) Stroke , vol.31 , pp. 1640-1645
    • Droste, D.W.1    Silling, K.2    Stypmann, J.3
  • 15
    • 0031803313 scopus 로고    scopus 로고
    • Validation of a transoesophageal ultrasonic doppler probe to the detection of air in the venous blood
    • Henze D, Menzel M, Lindner J, Roth S, Soukup J, Radke J. Validation of a transoesophageal ultrasonic doppler probe to the detection of air in the venous blood. Anaesthesist 1999; 47: 406-8
    • (1999) Anaesthesist. , vol.47 , pp. 406-408
    • Henze, D.1    Menzel, M.2    Lindner, J.3    Roth, S.4    Soukup, J.5    Radke, J.6
  • 16
    • 0031049057 scopus 로고    scopus 로고
    • The detection of carbon dioxide embolism during laparoscopy in pigs: A comparison of transesophageal doppler and end-tidal carbon dioxide monitoring
    • Mann C, Boccara G, Fabre JM, Grevy V, Colson P. The detection of carbon dioxide embolism during laparoscopy in pigs: a comparison of transesophageal doppler and end-tidal carbon dioxide monitoring. Acta Anaesthesiol Scand 1997; 41: 281-6
    • (1997) Acta Anaesthesiol. Scand. , vol.41 , pp. 281-286
    • Mann, C.1    Boccara, G.2    Fabre, J.M.3    Grevy, V.4    Colson, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.