메뉴 건너뛰기




Volumn 28, Issue 7, 2003, Pages 637-644

Bone ingrowth fixation of artificial intervertebral disc consisting of bioceramic-coated three-dimensional fabric

Author keywords

Artificial intervertebral disc; Bioactive ceramic; Bond strength; Bone ingrowth; Three dimensional polymer fabric

Indexed keywords

POLYETHYLENE;

EID: 0037384195     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BRS.0000051918.47287.3E     Document Type: Article
Times cited : (25)

References (35)
  • 1
    • 0023273877 scopus 로고
    • Long-term follow-up of lower lumbar fusion patients
    • Lehmann TR, Spratt KF, Tozzi JE, et al. Long-term follow-up of lower lumbar fusion patients. Spine 1987;12:97-104.
    • (1987) Spine , vol.12 , pp. 97-104
    • Lehmann, T.R.1    Spratt, K.F.2    Tozzi, J.E.3
  • 3
    • 0027319381 scopus 로고
    • Artificial disc replacement: Preliminary report with a 3-year minimum follow-up
    • Enker P, Steffee A, McMillin C, et al. Artificial disc replacement: Preliminary report with a 3-year minimum follow-up. Spine 1993;18:1061-70.
    • (1993) Spine , vol.18 , pp. 1061-1070
    • Enker, P.1    Steffee, A.2    McMillin, C.3
  • 4
    • 0030976090 scopus 로고    scopus 로고
    • Intervertebral disc replacement: Experimental study
    • Kostuik JP. Intervertebral disc replacement: Experimental study. Clin Orthop 1997;337:27-41.
    • (1997) Clin Orthop , vol.337 , pp. 27-41
    • Kostuik, J.P.1
  • 5
    • 0001900442 scopus 로고    scopus 로고
    • Biomechanical and histological analysis of total intervertebral disc replacement using bioactive three-dimensional fabrics
    • Kotani Y, Kaneda K, Abumi K, et al. Biomechanical and histological analysis of total intervertebral disc replacement using bioactive three-dimensional fabrics. Trans Orthop Res Soc 1999;204.
    • (1999) Trans Orthop Res Soc , pp. 204
    • Kotani, Y.1    Kaneda, K.2    Abumi, K.3
  • 6
    • 0028346697 scopus 로고
    • Mechanical evaluation of a canine intervertebral disc spacer: In situ and vivo studies
    • Vuono-Hawkins M, Zimmerman MC, Lee KC, et al. Mechanical evaluation of a canine intervertebral disc spacer: In situ and vivo studies. J Orthop Res 1994;12:119-27.
    • (1994) J Orthop Res , vol.12 , pp. 119-127
    • Vuono-Hawkins, M.1    Zimmerman, M.C.2    Lee, K.C.3
  • 7
    • 0030175621 scopus 로고    scopus 로고
    • The artificial disc: Theory, design, and materials
    • Bao QB, McCullen GM, Higham PA, et al. The artificial disc: Theory, design, and materials. Biomaterials 1996;17:1157-67.
    • (1996) Biomaterials , vol.17 , pp. 1157-1167
    • Bao, Q.B.1    McCullen, G.M.2    Higham, P.A.3
  • 8
    • 0025755335 scopus 로고
    • Development of a prosthetic intervertebral disc
    • Lee CK, Langrana NA, Parsons JR, et al. Development of a prosthetic intervertebral disc. Spine 1991;16(Suppl):253-5.
    • (1991) Spine , vol.16 , Issue.SUPPL. , pp. 253-255
    • Lee, C.K.1    Langrana, N.A.2    Parsons, J.R.3
  • 9
    • 0032052623 scopus 로고    scopus 로고
    • Potential application of a triaxial three-dimensional fabric (3-DF) as an implant
    • Shikinami Y, Kawarada H. Potential application of a triaxial three-dimensional fabric (3-DF) as an implant. Biomaterials 1998;19:617-35.
    • (1998) Biomaterials , vol.19 , pp. 617-635
    • Shikinami, Y.1    Kawarada, H.2
  • 10
    • 0033024784 scopus 로고    scopus 로고
    • Artificial disc replacement with the modular type SB Charite III: 2-year results in 50 prospectively studied patients
    • Zeegers WS, Bohnen LM, Laaper M, et al. Artificial disc replacement with the modular type SB Charite III: 2-year results in 50 prospectively studied patients. Eur Spine J 1999;8:210-7.
    • (1999) Eur Spine J , vol.8 , pp. 210-217
    • Zeegers, W.S.1    Bohnen, L.M.2    Laaper, M.3
  • 11
    • 0033635482 scopus 로고    scopus 로고
    • Early failure of modern cemented stems
    • Barrack RL. Early failure of modern cemented stems. J Arthroplasty 2000; 15:1036-50.
    • (2000) J Arthroplasty , vol.15 , pp. 1036-1050
    • Barrack, R.L.1
  • 13
  • 14
    • 0033645987 scopus 로고    scopus 로고
    • Proximal femoral bone loss and increased rate of fracture with a proximally hydroxyapatite-coated femoral component
    • Radl R, Aigner C, Hungerford M, et al. Proximal femoral bone loss and increased rate of fracture with a proximally hydroxyapatite-coated femoral component. J Bone Joint Surg [Br] 2000;82:1151-5.
    • (2000) J Bone Joint Surg [Br] , vol.82 , pp. 1151-1155
    • Radl, R.1    Aigner, C.2    Hungerford, M.3
  • 15
    • 0029871625 scopus 로고    scopus 로고
    • Results of disc prosthesis after a minimum follow-up period of 2 years
    • Cinotti G, David T, Postacchini F. Results of disc prosthesis after a minimum follow-up period of 2 years. Spine 1996;21:995-1000.
    • (1996) Spine , vol.21 , pp. 995-1000
    • Cinotti, G.1    David, T.2    Postacchini, F.3
  • 16
    • 0028132196 scopus 로고
    • A multicenter retrospective study of the clinical results of the LINK SB Charite intervertebral prosthesis: The initial European experience
    • Griffith SL, Shelokov AP, Buttner-Janz K, et al. A multicenter retrospective study of the clinical results of the LINK SB Charite intervertebral prosthesis: The initial European experience. Spine 1994;19:1842-9.
    • (1994) Spine , vol.19 , pp. 1842-1849
    • Griffith, S.L.1    Shelokov, A.P.2    Buttner-Janz, K.3
  • 17
    • 0036570931 scopus 로고    scopus 로고
    • Artificial intervertebral disc replacement using bioactive three dimensional fabric: Design, development, and preliminary animal study
    • Kotani Y, Abumi K, Shikinami Y, et al. Artificial intervertebral disc replacement using bioactive three dimensional fabric: Design, development, and preliminary animal study. Spine 2002;27:929-35.
    • (2002) Spine , vol.27 , pp. 929-935
    • Kotani, Y.1    Abumi, K.2    Shikinami, Y.3
  • 18
    • 0035879295 scopus 로고    scopus 로고
    • Biomechanical and morphologic evaluation of a three-dimensional fabric sheep artificial intervertebral
    • Kadoya K, Kotani Y, Abumi K, et al. Biomechanical and morphologic evaluation of a three-dimensional fabric sheep artificial intervertebral. Spine 2001;26:1562-9.
    • (2001) Spine , vol.26 , pp. 1562-1569
    • Kadoya, K.1    Kotani, Y.2    Abumi, K.3
  • 19
    • 0000156749 scopus 로고    scopus 로고
    • Segmental biomechanics and interface histology of artificial intervertebral disc replacement under different initial fixation conditions
    • Kotani Y, Kaneda K, Abumi K, et al. Segmental biomechanics and interface histology of artificial intervertebral disc replacement under different initial fixation conditions. Trans Orthop Res Soc 2000;333.
    • (2000) Trans Orthop Res Soc , pp. 333
    • Kotani, Y.1    Kaneda, K.2    Abumi, K.3
  • 21
    • 0026644452 scopus 로고
    • The treatment of osteoporotic-posttraumatic vertebral collapse using the Kaneda device and a bioactive ceramic vertebral prosthesis
    • Kaneda K, Asano S, Hashimoto T, et al. The treatment of osteoporotic-posttraumatic vertebral collapse using the Kaneda device and a bioactive ceramic vertebral prosthesis. Spine 1992;17:S295-303.
    • (1992) Spine , vol.17
    • Kaneda, K.1    Asano, S.2    Hashimoto, T.3
  • 22
    • 0022820413 scopus 로고
    • Bone bonding behavior of three kinds of apatite containing glass ceramics
    • Kitsugi T, Yamamuro T, Nakamura T, et al. Bone bonding behavior of three kinds of apatite containing glass ceramics. J Biomed Mater Res 1986;20: 1295-307.
    • (1986) J Biomed Mater Res , vol.20 , pp. 1295-1307
    • Kitsugi, T.1    Yamamuro, T.2    Nakamura, T.3
  • 23
    • 0022093658 scopus 로고
    • A new glass-ceramic for bone replacement: Evaluation of its bonding to bone tissue
    • Nakamura T, Yamamuro T, Higashi S, et al. A new glass-ceramic for bone replacement: Evaluation of its bonding to bone tissue. J Biomed Mater Res 1985;19:685-98.
    • (1985) J Biomed Mater Res , vol.19 , pp. 685-698
    • Nakamura, T.1    Yamamuro, T.2    Higashi, S.3
  • 24
    • 0344127348 scopus 로고    scopus 로고
    • Bioabsorbable spinal fixation using ultra-high-strength hydroxyapatite/poly-L-lactide composite
    • Kadoya K, Kotani Y, Abumi K, et al. Bioabsorbable spinal fixation using ultra-high-strength hydroxyapatite/poly-L-lactide composite. Trans Orthop Res Soc 2001;947.
    • (2001) Trans Orthop Res Soc , pp. 947
    • Kadoya, K.1    Kotani, Y.2    Abumi, K.3
  • 25
    • 0034000413 scopus 로고    scopus 로고
    • Biodegradation behavior of ultra-high-strength hydroxyapatite/poly (L-lactide) composite rods for internal fixation of bone fractures
    • Furukawa T, Matsusue Y, Yasunaga T. Biodegradation behavior of ultra-high-strength hydroxyapatite/poly (L-lactide) composite rods for internal fixation of bone fractures. Biomaterials 2000;21:889-98.
    • (2000) Biomaterials , vol.21 , pp. 889-898
    • Furukawa, T.1    Matsusue, Y.2    Yasunaga, T.3
  • 26
    • 9844263758 scopus 로고    scopus 로고
    • Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface
    • Edwards JT, Brunski JB, Higuchi HW. Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface. J Biomed Mater Res 1997;36:454-68.
    • (1997) J Biomed Mater Res , vol.36 , pp. 454-468
    • Edwards, J.T.1    Brunski, J.B.2    Higuchi, H.W.3
  • 27
    • 0032103926 scopus 로고    scopus 로고
    • Tensile tests of interface between bone and plasma-sprayed HA coating-tiranium implant
    • Lin H, Xu H, Zhang X, et al. Tensile tests of interface between bone and plasma-sprayed HA coating-tiranium implant. J Biomed Mater Res 1998;43: 113-22.
    • (1998) J Biomed Mater Res , vol.43 , pp. 113-122
    • Lin, H.1    Xu, H.2    Zhang, X.3
  • 28
    • 0027765535 scopus 로고
    • Computer simulations of stress-related bone remodeling around noncemented acetabular components
    • Levensron ME, Beaupre GS, Schurman DJ, et al. Computer simulations of stress-related bone remodeling around noncemented acetabular components. J Arthroplasty 1993;8:595-605.
    • (1993) J Arthroplasty , vol.8 , pp. 595-605
    • Levensron, M.E.1    Beaupre, G.S.2    Schurman, D.J.3
  • 29
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante J, Rostoker W, Lueck R, et al. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg [Am] 1971;53: 101-14.
    • (1971) J Bone Joint Surg [Am] , vol.53 , pp. 101-114
    • Galante, J.1    Rostoker, W.2    Lueck, R.3
  • 30
    • 0026410701 scopus 로고
    • Interstitial bone stress distributions accompanying ingrowth of a screen-like prosthesis anchorage layer
    • Pedersen DR, Brown TD, Brand RA. Interstitial bone stress distributions accompanying ingrowth of a screen-like prosthesis anchorage layer. J Biomech 1991;24:1131-42.
    • (1991) J Biomech , vol.24 , pp. 1131-1142
    • Pedersen, D.R.1    Brown, T.D.2    Brand, R.A.3
  • 32
    • 0019472503 scopus 로고
    • Radiographic and morphologic studies of load-bearing porous-surfaced structured implants
    • Pilliar RM, Cameron HU, Welsh RP, et al. Radiographic and morphologic studies of load-bearing porous-surfaced structured implants. Clin Orthop 1981;249-57.
    • (1981) Clin Orthop , pp. 249-257
    • Pilliar, R.M.1    Cameron, H.U.2    Welsh, R.P.3
  • 33
    • 0016934662 scopus 로고
    • An evaluation of bone growth into porous high-density polyethylene
    • Klawitter JJ, Bagwell JG, Weinstein AM, et al. An evaluation of bone growth into porous high-density polyethylene. J Biomed Mater Res 1976; 10:311-23.
    • (1976) J Biomed Mater Res , vol.10 , pp. 311-323
    • Klawitter, J.J.1    Bagwell, J.G.2    Weinstein, A.M.3
  • 35
    • 0028393411 scopus 로고
    • Comparison of primate and canine models for bone ingrowth experimentation, with reference to the effect of ovarian function on bone ingrowth potential
    • Shaw JA, Willson SC, Bruno A, et al. Comparison of primate and canine models for bone ingrowth experimentation, with reference to the effect of ovarian function on bone ingrowth potential. J Orthop Res 1994;12: 268-73.
    • (1994) J Orthop Res , vol.12 , pp. 268-273
    • Shaw, J.A.1    Willson, S.C.2    Bruno, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.