메뉴 건너뛰기




Volumn 49, Issue 4, 2003, Pages 709-710

Negative thyrotropin assay interference associated with an IgGκ paraprotein [4]

Author keywords

[No Author keywords available]

Indexed keywords

IMMUNOGLOBULIN KAPPA CHAIN; LIOTHYRONINE; PARAPROTEIN; THYROTROPIN; THYROXINE;

EID: 0037382496     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/49.4.709     Document Type: Letter
Times cited : (21)

References (8)
  • 1
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka LJ. Human anti-animal antibody interferences in immunological assays. Clin Chem 1999;45:942-56.
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 2
    • 0030765913 scopus 로고    scopus 로고
    • Heterophilic antibodies remain a problem for the immunoassay laboratory
    • Ward G, McKinnon L, Badrick T, Hickman PE. Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Pathol 1997;108:417-21.
    • (1997) Am J Clin Pathol , vol.108 , pp. 417-421
    • Ward, G.1    McKinnon, L.2    Badrick, T.3    Hickman, P.E.4
  • 3
    • 0027413250 scopus 로고
    • Modified method for determining carcinoembryonic antigen in the presence of human anti-murine antibodies
    • Morrisey NE, Quadri SF, Kinders R, Brigham C, Rose S, Blend MJ. Modified method for determining carcinoembryonic antigen in the presence of human anti-murine antibodies. Clin Chem 1993;39:522-9.
    • (1993) Clin Chem , vol.39 , pp. 522-529
    • Morrisey, N.E.1    Quadri, S.F.2    Kinders, R.3    Brigham, C.4    Rose, S.5    Blend, M.J.6
  • 5
    • 0028228321 scopus 로고
    • Human antidiotypic antibodies against OC125 strongly interfere with one-step assays of CA 125 employing OC125 and M11 antibodies
    • Reinsberg J, Gast B. Human antidiotypic antibodies against OC125 strongly interfere with one-step assays of CA 125 employing OC125 and M11 antibodies. Clin Chem 1994;40:951-2.
    • (1994) Clin Chem , vol.40 , pp. 951-952
    • Reinsberg, J.1    Gast, B.2
  • 6
    • 0030330910 scopus 로고    scopus 로고
    • False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies
    • Bohner J, vonPape K-W, Hannes W, Stegman T. False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies. Clin Chem 1996;42:2046.
    • (1996) Clin Chem , vol.42 , pp. 2046
    • Bohner, J.1    VonPape, K.-W.2    Hannes, W.3    Stegman, T.4
  • 7
    • 0003448569 scopus 로고
    • Cold Spring Harbor, NY: Cold Spring Harbor Laboratory
    • Harlow E, Lane D. Antibodies: a laboratory manual. Cold spring Harbor, NY: Cold Spring Harbor Laboratory, 1988:298-9.
    • (1988) Antibodies: A Laboratory Manual , pp. 298-299
    • Harlow, E.1    Lane, D.2
  • 8
    • 0031911110 scopus 로고    scopus 로고
    • Antibody interference in thyroid assays: A potential for clinical misinformation
    • Despres N, Grant AM. Antibody interference in thyroid assays: a potential for clinical misinformation. Clin Chem 1998;44:440-54.
    • (1998) Clin Chem , vol.44 , pp. 440-454
    • Despres, N.1    Grant, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.