메뉴 건너뛰기




Volumn 24, Issue 3, 2003, Pages 303-308

Technique for emergency medicine bedside ultrasound identification of a radiolucent foreign body

Author keywords

Emergency medicine; Foreign body; Spacer; Ultrasound

Indexed keywords

LATEX;

EID: 0037381912     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0736-4679(02)00765-5     Document Type: Article
Times cited : (23)

References (19)
  • 1
    • 0024233076 scopus 로고
    • Soft tissue foreign bodies
    • Lammers R.L. Soft tissue foreign bodies. Ann Emerg Med. 17:1988;1336-1347.
    • (1988) Ann Emerg Med , vol.17 , pp. 1336-1347
    • Lammers, R.L.1
  • 2
    • 0031020079 scopus 로고    scopus 로고
    • Ultrasound for the detection of foreign bodies in human tissue
    • Hill R., Conron R., Greissinger P., Heller M. Ultrasound for the detection of foreign bodies in human tissue. Ann Emerg Med. 29:1997;353-356.
    • (1997) Ann Emerg Med , vol.29 , pp. 353-356
    • Hill, R.1    Conron, R.2    Greissinger, P.3    Heller, M.4
  • 3
    • 0019947161 scopus 로고
    • Diagnosis and treatment of retained FBs in the hand
    • Anderson M.A., Leopold T., Evans R. Diagnosis and treatment of retained FBs in the hand. Am J Surg. 144:1982;63-67.
    • (1982) Am J Surg , vol.144 , pp. 63-67
    • Anderson, M.A.1    Leopold, T.2    Evans, R.3
  • 4
    • 0029902637 scopus 로고    scopus 로고
    • Ultrasound versus radiography in the detection of soft-tissue foreign bodies
    • Manthey D.E., Storrow A.B., Milbourn J.M., Wagner B.J. Ultrasound versus radiography in the detection of soft-tissue foreign bodies. Ann Emerg Med. 28:1996;7-9.
    • (1996) Ann Emerg Med , vol.28 , pp. 7-9
    • Manthey, D.E.1    Storrow, A.B.2    Milbourn, J.M.3    Wagner, B.J.4
  • 5
    • 0025959824 scopus 로고
    • Sonographic detection of foreign bodies of the extremities
    • Banerjee B., Das R.K. Sonographic detection of foreign bodies of the extremities. Br J Radiol. 64:1991;107-112.
    • (1991) Br J Radiol , vol.64 , pp. 107-112
    • Banerjee, B.1    Das, R.K.2
  • 6
    • 12244303826 scopus 로고    scopus 로고
    • The use of ultrasound in the emergency department
    • Schlager D. The use of ultrasound in the emergency department. Emerg Med Clin North Am. 15:1997;896-912.
    • (1997) Emerg Med Clin North Am , vol.15 , pp. 896-912
    • Schlager, D.1
  • 8
    • 0036143715 scopus 로고    scopus 로고
    • Ultrasound in the emergency department: Detection of wooden foreign bodies in the soft tissues
    • Graham D.D. Ultrasound in the emergency department detection of wooden foreign bodies in the soft tissues . J Emerg Med. 22:2002;75-79.
    • (2002) J Emerg Med , vol.22 , pp. 75-79
    • Graham, D.D.1
  • 9
    • 0025070039 scopus 로고
    • The role of ultrasound in the detection of non-radiopaque FBs
    • Gilbert F.J., Campbell R.S.D., Bayliss A.P. The role of ultrasound in the detection of non-radiopaque FBs. Clin Radiol. 41:1990;109-112.
    • (1990) Clin Radiol , vol.41 , pp. 109-112
    • Gilbert, F.J.1    Campbell, R.S.D.2    Bayliss, A.P.3
  • 10
    • 0033897310 scopus 로고    scopus 로고
    • Bedside emergency department ultrasonography in the evaluation of ocular pathology
    • Blaivas M. Bedside emergency department ultrasonography in the evaluation of ocular pathology. Acad Emerg Med. 7:2000;947-950.
    • (2000) Acad Emerg Med , vol.7 , pp. 947-950
    • Blaivas, M.1
  • 11
    • 0033162106 scopus 로고    scopus 로고
    • The ultrasound revolution
    • (letter)
    • Miller J. The ultrasound revolution. (letter) Acad Emerg Med. 6:1999;766.
    • (1999) Acad Emerg Med , vol.6 , pp. 766
    • Miller, J.1
  • 12
    • 0034234354 scopus 로고    scopus 로고
    • The comparative accuracy of radiolucent foreign body detection using ultrasonography
    • Orlinsky M., Knitel P., Feit T., Chan L., Mandavia D. The comparative accuracy of radiolucent foreign body detection using ultrasonography. Am J Emerg Med. 18:2000;401-403.
    • (2000) Am J Emerg Med , vol.18 , pp. 401-403
    • Orlinsky, M.1    Knitel, P.2    Feit, T.3    Chan, L.4    Mandavia, D.5
  • 13
    • 0024820162 scopus 로고
    • Clinical value of ultrasonography in the detection of radiolucent foreign bodies
    • Crawford R., Matheson A.B. Clinical value of ultrasonography in the detection of radiolucent foreign bodies. Injury. 20:1989;341-343.
    • (1989) Injury , vol.20 , pp. 341-343
    • Crawford, R.1    Matheson, A.B.2
  • 15
    • 0012718482 scopus 로고
    • Woodlands, TX: Educational Sonographic Professional Inc.
    • nd edn. Woodlands, TX: Educational Sonographic Professional Inc.; 1994.
    • (1994) nd Edn.
    • Edelman, S.K.1
  • 16
    • 0021186966 scopus 로고
    • Small-parts real-time sonography: A new water path
    • Fornage B.D., Touche D.H., Rifkin M.D. Small-parts real-time sonography a new water path . J Ultrasound Med. 3:1984;355-357.
    • (1984) J Ultrasound Med , vol.3 , pp. 355-357
    • Fornage, B.D.1    Touche, D.H.2    Rifkin, M.D.3
  • 17
    • 0034794416 scopus 로고    scopus 로고
    • Use of ultrasound imaging by emergency physicians
    • American College of Emergency Physicians. Use of ultrasound imaging by emergency physicians. Ann Emerg Med 2001;38. 469-70.
    • (2001) Ann Emerg Med , vol.38 , pp. 469-470
  • 18
    • 0035487042 scopus 로고    scopus 로고
    • ACEP emergency ultrasound guidelines - 2001
    • American College of Emergency Physicians. ACEP emergency ultrasound guidelines - 2001. Ann Emerg Med 2001;38.470-81.
    • (2001) Ann Emerg Med , vol.38 , pp. 470-481


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.