메뉴 건너뛰기




Volumn 58, Issue 3, 2003, Pages 275-280

Four French catheters for diagnostic coronary angiography

Author keywords

Cardiac catheterization; Catheter size; Coronary angiography

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; AORTA; ARTERY CATHETER; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC IMAGING; FEMALE; FLUOROSCOPY; HEART CATHETERIZATION; HEART LEFT VENTRICLE; HEMOSTASIS; HOSPITAL DISCHARGE; HUMAN; IMAGE QUALITY; LEFT CORONARY ARTERY; MAJOR CLINICAL STUDY; MALE; OBSERVER VARIATION; RENAL ARTERY; RIGHT CORONARY ARTERY; STATISTICAL ANALYSIS; VEIN GRAFT;

EID: 0037371666     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.10456     Document Type: Article
Times cited : (17)

References (20)
  • 3
    • 0028299598 scopus 로고
    • Outpatient coronary angiography: Safety and feasibility
    • Pohler E, Gunther H, Diekmann M, Eggeling T. Outpatient coronary angiography: safety and feasibility. Cardiology 1994;84:305-309.
    • (1994) Cardiology , vol.84 , pp. 305-309
    • Pohler, E.1    Gunther, H.2    Diekmann, M.3    Eggeling, T.4
  • 5
    • 0031930265 scopus 로고    scopus 로고
    • Outpatient coronary angiography: Indications, safety, and complication rates
    • Heuser RR. Outpatient coronary angiography: indications, safety, and complication rates. Herz 1998;23:21-26.
    • (1998) Herz , vol.23 , pp. 21-26
    • Heuser, R.R.1
  • 7
    • 0023792772 scopus 로고
    • Vascular complications of percutaneous femoral cardiac interventions: Incidence and operative repair
    • Skillman JJ, Kim D, Baim DS. Vascular complications of percutaneous femoral cardiac interventions: incidence and operative repair. Arch Surg 1988;123:1207-1212.
    • (1988) Arch Surg , vol.123 , pp. 1207-1212
    • Skillman, J.J.1    Kim, D.2    Baim, D.S.3
  • 8
    • 0031054336 scopus 로고    scopus 로고
    • Systematic use of 4 French catheters for left heart catheterization and coronary angiographies
    • Meyer P, Gervais A, Touati C. Systematic use of 4 French catheters for left heart catheterization and coronary angiographies. Arch Mal Coeur Vaiss 1997;90:35-40.
    • (1997) Arch Mal Coeur Vaiss , vol.90 , pp. 35-40
    • Meyer, P.1    Gervais, A.2    Touati, C.3
  • 9
    • 0023263068 scopus 로고
    • Use of 5 French catheters for cardiac catheterization and coronary angiography: A critical review
    • Brown RI, MacDonald AC. Use of 5 French catheters for cardiac catheterization and coronary angiography: a critical review. Cathet Cardiovasc Diagn 1987;13:214-217.
    • (1987) Cathet Cardiovasc Diagn , vol.13 , pp. 214-217
    • Brown, R.I.1    MacDonald, A.C.2
  • 10
    • 0023179491 scopus 로고
    • Comparison of the performance of superflow (5 Fr) and conventional 8F catheter for cardiac catheterization by the femoral route
    • Molajo AO, Ward C, Bray CL, Dobson D. Comparison of the performance of superflow (5 Fr) and conventional 8F catheter for cardiac catheterization by the femoral route. Cathet Cardiovasc Diagn 1987;13:275-276.
    • (1987) Cathet Cardiovasc Diagn , vol.13 , pp. 275-276
    • Molajo, A.O.1    Ward, C.2    Bray, C.L.3    Dobson, D.4
  • 11
    • 0024378508 scopus 로고
    • Study of the performance of 5 French and 7 French catheters in coronary angiography: A functional comparison
    • Kohli RS, Vetrovec GW, Lewis SA, Cole S. Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison. Cathet Cardiovasc Diagn 1989;18:131-135.
    • (1989) Cathet Cardiovasc Diagn , vol.18 , pp. 131-135
    • Kohli, R.S.1    Vetrovec, G.W.2    Lewis, S.A.3    Cole, S.4
  • 12
    • 0025322084 scopus 로고
    • Comparison of 5 Fr and 7/8F catheters for left ventricular and coronary angiography
    • Hui WK, Klinke WP, Kubac G, Talibi T. Comparison of 5 Fr and 7/8F catheters for left ventricular and coronary angiography. Cathet Cardiovasc Diagn 1990;19:84-86.
    • (1990) Cathet Cardiovasc Diagn , vol.19 , pp. 84-86
    • Hui, W.K.1    Klinke, W.P.2    Kubac, G.3    Talibi, T.4
  • 14
    • 0026185339 scopus 로고
    • Use of 5 French catheters in percutaneous femoral coronaroventriculography (500 consecutive procedures with 5 French catheters)
    • Carosio G, Taverna G, Ballestrero G, Reale M, Massa R, Ravazzi PA. Use of 5 French catheters in percutaneous femoral coronaroventriculography (500 consecutive procedures with 5 French catheters). G Ital Cardiol 1991;21:725-730.
    • (1991) G Ital Cardiol , vol.21 , pp. 725-730
    • Carosio, G.1    Taverna, G.2    Ballestrero, G.3    Reale, M.4    Massa, R.5    Ravazzi, P.A.6
  • 15
    • 0026826388 scopus 로고
    • Ambulatory coronary arteriography with 5 French catheters: Experience with 604 procedures
    • Tamburino C, Corcos T, Favereau X, Russo G, Giuffrida G. Ambulatory coronary arteriography with 5 French catheters: experience with 604 procedures. Cardiologia 1992;37:203-206.
    • (1992) Cardiologia , vol.37 , pp. 203-206
    • Tamburino, C.1    Corcos, T.2    Favereau, X.3    Russo, G.4    Giuffrida, G.5
  • 17
    • 0026527394 scopus 로고
    • Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures
    • Muller DW, Shamir KJ, Ellis SG, Topol EJ. Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures. Am J Cardiol 1992;69:63-68.
    • (1992) Am J Cardiol , vol.69 , pp. 63-68
    • Muller, D.W.1    Shamir, K.J.2    Ellis, S.G.3    Topol, E.J.4
  • 19
    • 0032929256 scopus 로고    scopus 로고
    • Randomized evaluation of four versus five French catheters for transfemoral coronary angiography
    • Metz D, Chapoutot L, Brasselet C, Jolly D. Randomized evaluation of four versus five French catheters for transfemoral coronary angiography. Clin Cardiol 1999;22:29-32.
    • (1999) Clin Cardiol , vol.22 , pp. 29-32
    • Metz, D.1    Chapoutot, L.2    Brasselet, C.3    Jolly, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.