메뉴 건너뛰기




Volumn 58, Issue 3, 2003, Pages 309-314

Preparation of high specific-volume solutions of technetium-99m and rhenium-188

Author keywords

188W 188Re generator; 99Mo 99mTc generator; Acetone as an eluant; Post elution concentration of perrhenate; Post elution concentration of pertechnetate

Indexed keywords

ACETONE; ALUMINA; CHROMATOGRAPHIC ANALYSIS; EVAPORATION; NEUTRON IRRADIATION; RHODIUM; SOLUTIONS;

EID: 0037366336     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(02)00353-6     Document Type: Article
Times cited : (25)

References (9)
  • 1
    • 0027330189 scopus 로고
    • 99mTc generator: A simple and convenient method for concentrating generator eluate for clinical use
    • 99mTc generator. a simple and convenient method for concentrating generator eluate for clinical use Nucl. Med. Commun. 14:1993;995-997.
    • (1993) Nucl. Med. Commun. , vol.14 , pp. 995-997
    • Blower, P.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.