Feasible measurement errors when undertaking in vivo dosimetry during external beam radiotherapy of the breast

Author keywords

Breast; In vivo dosimetry; Radiotherapy

Indexed keywords

ACCURACY; ARTICLE; BEAM THERAPY; BODY BUILD; BODY REGIONS; BREAST DISEASE; CONTROLLED STUDY; DIODE; DOSIMETRY; ERROR; FEASIBILITY STUDY; HUMAN; IN VIVO STUDY; INFORMATION PROCESSING; IRRADIATION; MAJOR CLINICAL STUDY; MONTE CARLO METHOD; PILOT STUDY; PREDICTION; PRIORITY JOURNAL; RADIATION DOSE; RADIATION FIELD;

EID: 0037363254     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(02)00241-8     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • Essers M., Mijnheer B.J. In vivo dosimetry during external photon beam radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 43:1999;245-259.
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.43 , pp. 245-259
    • Essers, M.1    Mijnheer, B.J.2
  • 2
    • 0025166575 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
    • Leunens G., van Dam J., Dutreix A., van der Schueren E. Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedure. Radiother. Oncol. 17:1990;141-151.
    • (1990) Radiother. Oncol. , vol.17 , pp. 141-151
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van der Schueren, E.4
  • 3
    • 0027994644 scopus 로고
    • Patient dosimetry quality assurance program with a commercial diode system
    • Lee P., Sawicka J., Glasgow G. Patient dosimetry quality assurance program with a commercial diode system. Int. J. Radiat. Oncol. Biol. Phys. 29:1994;1175-1182.
    • (1994) Int. J. Radiat. Oncol. Biol. Phys. , vol.29 , pp. 1175-1182
    • Lee, P.1    Sawicka, J.2    Glasgow, G.3
  • 4
    • 0029376597 scopus 로고
    • A patient dose verification program using diode detectors
    • Li C., Lamel L., Tom D. A patient dose verification program using diode detectors. Med. Dosim. 20:1995;209-214.
    • (1995) Med. Dosim. , vol.20 , pp. 209-214
    • Li, C.1    Lamel, L.2    Tom, D.3
  • 5
    • 0027145156 scopus 로고
    • In vivo dosimetry during conformal therapy of prostatic cancer
    • Essers M., Lanson J.H., Mijnheer B.J. In vivo dosimetry during conformal therapy of prostatic cancer. Radiother. Oncol. 29:1993;271-279.
    • (1993) Radiother. Oncol. , vol.29 , pp. 271-279
    • Essers, M.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 6
    • 0345057179 scopus 로고
    • Methods for in vivo dosimetry in external radiotherapy. Physics for clinical radiotherapy
    • Belgium: Garant
    • van Dam J., Marinello G. Methods for in vivo dosimetry in external radiotherapy. Physics for clinical radiotherapy. ESTRO Booklet No. 1. 1994;Garant, Belgium.
    • (1994) ESTRO Booklet No. 1
    • Van Dam, J.1    Marinello, G.2
  • 7
    • 0025960367 scopus 로고
    • Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes
    • Heukelom S., Lanson J.H., Mijnheer B.J. Comparison of entrance and exit dose measurements using ionization chambers and silicon diodes. Phys. Med. Biol. 36:1991;47-59.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 47-59
    • Heukelom, S.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 8
    • 0023870307 scopus 로고
    • Characteristics of silicon diodes as patient dosimeters in external radiation therapy
    • Nilsson B., Rudèn B.-I., Sorcini B. Characteristics of silicon diodes as patient dosimeters in external radiation therapy. Radiother. Oncol. 11:1988;279-288.
    • (1988) Radiother. Oncol. , vol.11 , pp. 279-288
    • Nilsson, B.1    Rudèn, B.-I.2    Sorcini, B.3
  • 9
    • 0023622870 scopus 로고
    • General specification for silicon semiconductors for use in radiation dosimetry
    • Rikner G., Grusell E. General specification for silicon semiconductors for use in radiation dosimetry. Phys. Med. Biol. 32:1987;1109-1117.
    • (1987) Phys. Med. Biol. , vol.32 , pp. 1109-1117
    • Rikner, G.1    Grusell, E.2
  • 10
    • 0023620571 scopus 로고
    • Patient dose measurements in photon fields by means of silicon semiconductor detectors
    • Rikner G., Grusell E. Patient dose measurements in photon fields by means of silicon semiconductor detectors. Med. Phys. 14:1987;870-873.
    • (1987) Med. Phys. , vol.14 , pp. 870-873
    • Rikner, G.1    Grusell, E.2
  • 11
    • 0029591848 scopus 로고
    • Calibration of entrance dose measurements for an in vivo dosimetry programme
    • Ding W., Patterson W., Tremethick L., Joseph D. Calibration of entrance dose measurements for an in vivo dosimetry programme. Austr. Radiol. 39:1995;369-374.
    • (1995) Austr. Radiol. , vol.39 , pp. 369-374
    • Ding, W.1    Patterson, W.2    Tremethick, L.3    Joseph, D.4
  • 12
    • 0031961068 scopus 로고    scopus 로고
    • Quality assurance in radiation oncology. A study of feasability and impact on dose levels of an in vivo dosimetry program during breast cancer irradiation
    • Cozzi L., Fogliata-Cozzi A. Quality assurance in radiation oncology. A study of feasability and impact on dose levels of an in vivo dosimetry program during breast cancer irradiation. Radiother. Oncol. 47:1998;29-36.
    • (1998) Radiother. Oncol. , vol.47 , pp. 29-36
    • Cozzi, L.1    Fogliata-Cozzi, A.2
  • 13
    • 0034237747 scopus 로고    scopus 로고
    • Quality assurance by systematic in vivo dosimetry: Results on a large cohort of patients
    • Fiorino C., Corletto D., Mangili P., et al. Quality assurance by systematic in vivo dosimetry Results on a large cohort of patients . Radiother. Oncol. 56:2000;85-95.
    • (2000) Radiother. Oncol. , vol.56 , pp. 85-95
    • Fiorino, C.1    Corletto, D.2    Mangili, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.