메뉴 건너뛰기




Volumn 55, Issue 3, 2003, Pages 757-767

Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification

Author keywords

Cone beam CT; Electronic portal imaging device; Megavoltage CT; Radiotherapy planning; Treatment verification

Indexed keywords

COMPUTERIZED TOMOGRAPHY; IMAGING TECHNIQUES; OPTIMIZATION; PROBABILITY; TISSUE;

EID: 0037359882     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(02)04152-4     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 0028109644 scopus 로고
    • Real time beam monitoring in dynamic conformal therapy
    • Nakagawa K., Aoki Y., Akanuma A., et al. Real time beam monitoring in dynamic conformal therapy. Int J Radiat Oncol Biol Phys. 30:1994;1233-1238.
    • (1994) Int J Radiat Oncol Biol Phys , vol.30 , pp. 1233-1238
    • Nakagawa, K.1    Aoki, Y.2    Akanuma, A.3
  • 2
    • 0024442522 scopus 로고
    • Irradiation synchronized with respiration gate
    • Ohara K., Okumura T., Akisada M., et al. Irradiation synchronized with respiration gate. Int J Radiat Oncol Biol Phys. 17:(4):1989;853-857.
    • (1989) Int J Radiat Oncol Biol Phys , vol.17 , Issue.4 , pp. 853-857
    • Ohara, K.1    Okumura, T.2    Akisada, M.3
  • 3
    • 0033007343 scopus 로고    scopus 로고
    • Clinical efficacy of respiratory gated conformal radiation therapy
    • Ramsey C.R., Scaperoth D., Arwood D., Oliver A.L. Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim. 24:1999;115-119.
    • (1999) Med Dosim , vol.24 , pp. 115-119
    • Ramsey, C.R.1    Scaperoth, D.2    Arwood, D.3    Oliver, A.L.4
  • 4
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • Shirato H., Shimizu S., Kunieda T., et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys. 48:2000;1187-1195.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1187-1195
    • Shirato, H.1    Shimizu, S.2    Kunieda, T.3
  • 5
    • 0347028445 scopus 로고    scopus 로고
    • Cone-beam CT for radiation treatment verification with megavoltage beams and an amorphous-Silicon imager
    • (Abstract) July
    • Ford E.C., Chang J., Mueller K., et al. Cone-beam CT for radiation treatment verification with megavoltage beams and an amorphous-Silicon imager. AAPM. 2001;. (Abstract) July.
    • (2001) AAPM
    • Ford, E.C.1    Chang, J.2    Mueller, K.3
  • 6
    • 0026570956 scopus 로고
    • A review of electronic portal imaging devices (EPIDs)
    • Boyer A.L., Antonuk L., Fenster A., et al. A review of electronic portal imaging devices (EPIDs). Med Phys. 19:1992;1-16.
    • (1992) Med Phys , vol.19 , pp. 1-16
    • Boyer, A.L.1    Antonuk, L.2    Fenster, A.3
  • 7
    • 0028915337 scopus 로고
    • Portal imaging technology: Past, present, and future
    • Munro P. Portal imaging technology Past, present, and future . Semin Radiat Oncol. 5:1995;115-133.
    • (1995) Semin Radiat Oncol , vol.5 , pp. 115-133
    • Munro, P.1
  • 8
    • 0012931773 scopus 로고
    • Megavoltage CT scanner on a linear accelerator unit for patient set-up
    • Akanuma A., Nakagawa K., Aoki Y., et al. Megavoltage CT scanner on a linear accelerator unit for patient set-up. Radiother Oncol. 24:1992;S34.
    • (1992) Radiother Oncol , vol.24 , pp. 34
    • Akanuma, A.1    Nakagawa, K.2    Aoki, Y.3
  • 9
    • 0023093919 scopus 로고
    • Radiotherapeutic computed tomography with scanned photon beams
    • Brahme A., Lind B., Nafstadius P. Radiotherapeutic computed tomography with scanned photon beams. Int J Radiat Oncol Biol Phys. 13:1987;95-101.
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , pp. 95-101
    • Brahme, A.1    Lind, B.2    Nafstadius, P.3
  • 11
    • 0031935731 scopus 로고    scopus 로고
    • A feasibility study for megavoltage cone beam CT using a commercial EPID
    • Midgley S., Millar R.M., Dudson J. A feasibility study for megavoltage cone beam CT using a commercial EPID. Phys Med Biol. 43:1998;155-169.
    • (1998) Phys Med Biol , vol.43 , pp. 155-169
    • Midgley, S.1    Millar, R.M.2    Dudson, J.3
  • 12
    • 0031790660 scopus 로고    scopus 로고
    • A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy
    • Mosleh-Shirazi M.A., Evans P.M., Swindell W., Webb S., Partridge M. A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. Radiother Oncol. 48:1998;319-328.
    • (1998) Radiother Oncol , vol.48 , pp. 319-328
    • Mosleh-Shirazi, M.A.1    Evans, P.M.2    Swindell, W.3    Webb, S.4    Partridge, M.5
  • 13
    • 34249831143 scopus 로고
    • Technological features and clinical feasibility of megavoltage CT scanning
    • Nakagawa K., Aoki Y., Akanuma A., et al. Technological features and clinical feasibility of megavoltage CT scanning. Eur Radiol. 2:1992;184-189.
    • (1992) Eur Radiol , vol.2 , pp. 184-189
    • Nakagawa, K.1    Aoki, Y.2    Akanuma, A.3
  • 14
    • 0020559807 scopus 로고
    • Computed tomography with a linear accelerator with radiotherapy applications
    • Swindell W., Simpson R.G., Oleson J.R. Computed tomography with a linear accelerator with radiotherapy applications. Med Phys. 10:1983;416-420.
    • (1983) Med Phys , vol.10 , pp. 416-420
    • Swindell, W.1    Simpson, R.G.2    Oleson, J.R.3
  • 17
    • 0023761406 scopus 로고
    • A comprehensive three-dimensional radiation treatment planning system
    • Mohan R., Barest G., Brewster L.J., et al. A comprehensive three-dimensional radiation treatment planning system. Int J Radiat Oncol Biol Phys. 15:1988;481-495.
    • (1988) Int J Radiat Oncol Biol Phys , vol.15 , pp. 481-495
    • Mohan, R.1    Barest, G.2    Brewster, L.J.3
  • 18
    • 0031895424 scopus 로고    scopus 로고
    • A gradient inverse planning algorithm with dose-volume constraints
    • Spirou S.V., Chui C.-S. A gradient inverse planning algorithm with dose-volume constraints. Med Phys. 25:1998;321-333.
    • (1998) Med Phys , vol.25 , pp. 321-333
    • Spirou, S.V.1    Chui, C.-S.2
  • 19
    • 0028071498 scopus 로고
    • Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multi-leaf collimations
    • Chui C.S., LoSasso T., Spirou S.V. Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multi-leaf collimations. Med Phys. 21:1994;1237-1244.
    • (1994) Med Phys , vol.21 , pp. 1237-1244
    • Chui, C.S.1    LoSasso, T.2    Spirou, S.V.3
  • 20
    • 0032840324 scopus 로고    scopus 로고
    • Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer
    • Graham M.V., Purdy J.A., Emami B., et al. Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer. Int J Radiat Oncol Biol Phys. 45:1999;323-329.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 323-329
    • Graham, M.V.1    Purdy, J.A.2    Emami, B.3
  • 22
    • 0027222535 scopus 로고
    • Probability of radiation induced complication in normal tissues with parallel architecture: Non-uniform irradiation
    • Jackson A., Kutcher G.J., Yorke E.D. Probability of radiation induced complication in normal tissues with parallel architecture Non-uniform irradiation . Med Phys. 20:1993;613-625.
    • (1993) Med Phys , vol.20 , pp. 613-625
    • Jackson, A.1    Kutcher, G.J.2    Yorke, E.D.3
  • 23
    • 0000410361 scopus 로고    scopus 로고
    • A conformal dose escalation protocol for the treatment of tumors in the lung or other normal tissues with parallel architecture
    • (Abstr.)
    • Jackson A., Ling C.C., Burman C.M., et al. A conformal dose escalation protocol for the treatment of tumors in the lung or other normal tissues with parallel architecture. (Abstr.) Med Phys. 23:1996;1495.
    • (1996) Med Phys , vol.23 , pp. 1495
    • Jackson, A.1    Ling, C.C.2    Burman, C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.