메뉴 건너뛰기




Volumn 9, Issue 1, 2003, Pages 3-11

History, background, and development of the Herbst appliance

Author keywords

[No Author keywords available]

Indexed keywords

DENTIST; DENTISTRY; DISEASE SEVERITY; EQUIPMENT DESIGN; GERMANY; HUMAN; MALOCCLUSION; ORTHODONTIC DEVICE; ORTHODONTICS; PATIENT SELECTION; REVIEW; UNITED STATES;

EID: 0037354332     PISSN: 10738746     EISSN: None     Source Type: Journal    
DOI: 10.1053/sodo.2003.34020     Document Type: Review
Times cited : (29)

References (22)
  • 3
    • 0001249234 scopus 로고
    • Dreissigjährige Erfahrungen mit dem Retentions-Scharnier
    • 1515-1524, 1563-1568
    • Herbst E. Dreissigjährige Erfahrungen mit dem Retentions-Scharnier. Zahnärztl Rundschau 1934;43:1515-1524, 1563-1568, 1611-1616.
    • (1934) Zahnärztl Rundschau , vol.43 , pp. 1611-1616
    • Herbst, E.1
  • 4
    • 0012793475 scopus 로고
    • Erfahrungen mit dem Herbstschen Scharnier zur Behandlung des Distalbisses
    • 47-54
    • Schwarz M. Erfahrungen mit dem Herbstschen Scharnier zur Behandlung des Distalbisses. Zahnärztl Rundschau 1934;43:47-54, 91-100.
    • (1934) Zahnärztl Rundschau , vol.43 , pp. 91-100
    • Schwarz, M.1
  • 5
    • 85031210244 scopus 로고    scopus 로고
    • Positionsveränderungen und Belastungsschäden der Ankerzähne bei der Herbst-Behandlung
    • Giessen, Germany: Diss med dent
    • Pietz I. Positionsveränderungen und Belastungsschäden der Ankerzähne bei der Herbst-Behandlung. Giessen, Germany: Diss med dent, 2000.
    • (2000)
    • Pietz, I.1
  • 6
    • 0018535188 scopus 로고
    • Treatment of Class II malocclusions by jumping the bite with the Herbst appliance
    • Pancherz H. Treatment of Class II malocclusions by jumping the bite with the Herbst appliance. Am J Orthod 1979;76:423-442.
    • (1979) Am. J. Orthod. , vol.76 , pp. 423-442
    • Pancherz, H.1
  • 7
    • 0020418820 scopus 로고
    • The mechnism of Class II correction in Herbst appliance treatment. A cephalometric investigation
    • Pancherz H. The mechnism of Class II correction in Herbst appliance treatment. A cephalometric investigation. Am J Orthod 1982;82:104-143.
    • (1982) Am. J. Orthod. , vol.82 , pp. 104-143
    • Pancherz, H.1
  • 8
    • 0032185063 scopus 로고    scopus 로고
    • Effective condylar growth and chin position changes in Herbst treatment: A cephalometric long-term study
    • Pancherz H, Ruf S, Kohlhas P. Effective condylar growth and chin position changes in Herbst treatment: A cephalometric long-term study. Am J Orthod Dentofac Orthop 1998;114:437-446.
    • (1998) Am. J. Orthod. Dentofac. Orthop. , vol.114 , pp. 437-446
    • Pancherz, H.1    Ruf, S.2    Kohlhas, P.3
  • 9
    • 0032133930 scopus 로고    scopus 로고
    • Temporomandibular joint growth adaptation in Herbst treatment: A prospective magnetic resonance imaging and cephalometric roentgenographic study
    • Ruf S, Pancherz H. Temporomandibular joint growth adaptation in Herbst treatment: A prospective magnetic resonance imaging and cephalometric roentgenographic study. Eur J Orthod 1998;20:375-388.
    • (1998) Eur. J. Orthod. , vol.20 , pp. 375-388
    • Ruf, S.1    Pancherz, H.2
  • 10
    • 0012795288 scopus 로고    scopus 로고
    • Temporomandibular joint remodeling in adolescents and young adults during Herbst treatment: A prospective longitudinal magnetic resonance imaging and cephalometric radiographic investigation
    • Ruf S, Pancherz H. Temporomandibular joint remodeling in adolescents and young adults during Herbst treatment: A prospective longitudinal magnetic resonance imaging and cephalometric radiographic investigation. Am J Orthod Dentofac Orthop 1999;116:207-214.
    • (1999) Am. J. Orthod. Dentofac. Orthop. , vol.116 , pp. 207-214
    • Ruf, S.1    Pancherz, H.2
  • 11
    • 77956981311 scopus 로고
    • Mandibular anchorage in Herbst treatment
    • Pancherz H, Hansen K. Mandibular anchorage in Herbst treatment. Eur J Orthod 1988;10:149-164.
    • (1988) Eur. J. Orthod. , vol.10 , pp. 149-164
    • Pancherz, H.1    Hansen, K.2
  • 12
    • 0019604391 scopus 로고
    • The Herbst appliance
    • Langford NM. The Herbst appliance. J Clin Orthod 1981;15:558-561.
    • (1981) J. Clin. Orthod. , vol.15 , pp. 558-561
    • Langford, N.M.1
  • 13
    • 0022154220 scopus 로고
    • Modified Herbst appliance for the mixed dentition
    • Goodman P, McKenna P. Modified Herbst appliance for the mixed dentition. J Clin Orthod 1985;19:811-814.
    • (1985) J. Clin. Orthod. , vol.19 , pp. 811-814
    • Goodman, P.1    McKenna, P.2
  • 14
    • 0024727761 scopus 로고
    • Edgewise bioprogressive Herbst appliance
    • Dischinger TG. Edgewise bioprogressive Herbst appliance. J Clin Orthod 1989;23:608-612.
    • (1989) J. Clin. Orthod. , vol.23 , pp. 608-612
    • Dischinger, T.G.1
  • 15
    • 0020199842 scopus 로고
    • The bonded Herbst appliance
    • Howe RP. The bonded Herbst appliance. J Clin Orthod 1982;16:663-667.
    • (1982) J. Clin. Orthod. , vol.16 , pp. 663-667
    • Howe, R.P.1
  • 16
    • 0020793977 scopus 로고
    • Clinical management of the bonded Herbst appliance
    • Howe RP, McNamara JA. Clinical management of the bonded Herbst appliance. J Clin Orthod 1983;17:456-463.
    • (1983) J. Clin. Orthod. , vol.17 , pp. 456-463
    • Howe, R.P.1    McNamara, J.A.2
  • 17
    • 84858269402 scopus 로고
    • Improving appliance efficiency with the cantilever Herbst-A new answer to old problems
    • 2-5
    • Mayes JH. Improving appliance efficiency with the cantilever Herbst-A new answer to old problems. Clin Impressions 1994;3:2-5, 17-19.
    • (1994) Clin. Impressions , vol.3 , pp. 17-19
    • Mayes, J.H.1
  • 18
    • 0003512066 scopus 로고
    • Atlas und Grundriss der Zahnärztlichen Orthopädie. 2
    • Auflage. München: J.F. Lehmanns Verlag
    • Herbst E. Atlas und Grundriss der Zahnärztlichen Orthopädie. 2. Auflage. München: J.F. Lehmanns Verlag, 1922.
    • (1922)
    • Herbst, E.1
  • 19
    • 0012796248 scopus 로고
    • Das Federgelenk, ein Gerät zur Behebung falscher Bisslagen bei Verwendung der üblichen aktiven Plattenbehelfe
    • Fränkel R. Das Federgelenk, ein Gerät zur Behebung falscher Bisslagen bei Verwendung der üblichen aktiven Plattenbehelfe. Fortschr Kieferorthop 1956; 17:132-136.
    • (1956) Fortschr. Kieferorthop. , vol.17 , pp. 132-136
    • Fränkel, R.1
  • 20
    • 0012796249 scopus 로고
    • The Jasper Jumper-A fixed functional appliance
    • Sheboygan Wisconsin: American Orthodontics
    • Jasper JJ. The Jasper Jumper-A fixed functional appliance. Sheboygan Wisconsin: American Orthodontics, 1987.
    • (1987)
    • Jasper, J.J.1
  • 21
    • 0031174437 scopus 로고    scopus 로고
    • The Eureka Spring: A new interarch force delivery system
    • De Vincenco J. The Eureka Spring: a new interarch force delivery system. J Clin Orthod 1997;31:454-467.
    • (1997) J. Clin. Orthod. , vol.31 , pp. 454-467
    • De Vincenco, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.