-
1
-
-
0025337551
-
Vein graft surveillance improves patency in femoro-popliteal bypass
-
Moody P, Gould DA, Harris PL. Vein graft surveillance improves patency in femoro-popliteal bypass. Eur J Vasc Surg 1990;4:117-21.
-
(1990)
Eur J Vasc Surg
, vol.4
, pp. 117-121
-
-
Moody, P.1
Gould, D.A.2
Harris, P.L.3
-
2
-
-
0025158577
-
The importance of routine surveillance of distal bypass grafts with duplex scanning: A study of 379 reverse vein grafts
-
Mills JL, Harris EJ, Taylor LM Jr, Beckett WC, Porter JM. The importance of routine surveillance of distal bypass grafts with duplex scanning: a study of 379 reverse vein grafts. J Vasc Surg 1990;12:379-89.
-
(1990)
J Vasc Surg
, vol.12
, pp. 379-389
-
-
Mills, J.L.1
Harris, E.J.2
Taylor L.M., Jr.3
Beckett, W.C.4
Porter, J.M.5
-
3
-
-
0029061248
-
Intensive surveillance of femoropopliteal-tibial autogenous vein bypasses improves long-term graft patency and limb salvage
-
Bergamini TM, George SM Jr, Massey HT, Henke PK, Klamer TW, Lambert GE, et al. Intensive surveillance of femoropopliteal-tibial autogenous vein bypasses improves long-term graft patency and limb salvage. Ann Surg 1995;221:507-18.
-
(1995)
Ann Surg
, vol.221
, pp. 507-518
-
-
Bergamini, T.M.1
George S.M., Jr.2
Massey, H.T.3
Henke, P.K.4
Klamer, T.W.5
Lambert, G.E.6
-
4
-
-
0028832989
-
Femoropopliteal-crural graft patency is improved by ABI intensive surveillance program: A prospective randomized study
-
Lundell A, Lindblad B, Berquist D, Hansen F. Femoropopliteal-crural graft patency is improved by ABI intensive surveillance program: a prospective randomized study. J Vasc Surg 1995;21:26-34.
-
(1995)
J Vasc Surg
, vol.21
, pp. 26-34
-
-
Lundell, A.1
Lindblad, B.2
Berquist, D.3
Hansen, F.4
-
5
-
-
0035145425
-
Duplex scan surveillance during the first year after autologous vein bypass surgery: Costs and clinical outcomes compared with other surveillance programs
-
Visser K, Idu MM, Buth J, Engel GL, Hunink MG. Duplex scan surveillance during the first year after autologous vein bypass surgery: costs and clinical outcomes compared with other surveillance programs. J Vasc Surg 2001;33:123-30.
-
(2001)
J Vasc Surg
, vol.33
, pp. 123-130
-
-
Visser, K.1
Idu, M.M.2
Buth, J.3
Engel, G.L.4
Hunink, M.G.5
-
6
-
-
0026605483
-
Causes of primary graft failure after in situ saphenous vein grafting
-
Donaldson MC, Mannick JA, Whittemore AD. Causes of primary graft failure after in situ saphenous vein grafting. J Vasc Surg 1992;15:113-20.
-
(1992)
J Vasc Surg
, vol.15
, pp. 113-120
-
-
Donaldson, M.C.1
Mannick, J.A.2
Whittemore, A.D.3
-
7
-
-
0029786077
-
Natural history of infrainguinal vein bypass stenoses: Early lesions increase the risk of thrombosis
-
Nielsen TG. Natural history of infrainguinal vein bypass stenoses: early lesions increase the risk of thrombosis. Eur J Vasc Endovasc Surg 1996;12:60-4.
-
(1996)
Eur J Vasc Endovasc Surg
, vol.12
, pp. 60-64
-
-
Nielsen, T.G.1
-
8
-
-
0035106687
-
The natural history of intermediate and critical vein graft stenosis: Recommendations for continued surveillance or repair
-
Mills JL Sr, Wixon CL, James DC, Devine J, Westerband A, Hughes JD. The natural history of intermediate and critical vein graft stenosis: recommendations for continued surveillance or repair. J Vasc Surg 2001;33:273-80.
-
(2001)
J Vasc Surg
, vol.33
, pp. 273-280
-
-
Mills J.L., Sr.1
Wixon, C.L.2
James, D.C.3
Devine, J.4
Westerband, A.5
Hughes, J.D.6
-
9
-
-
0027513418
-
The characteristics and anatomic distribution of lesions that cause reversed vein graft failure: A five-year prospective study
-
Mills JL, Fujitani RM, Taylor SM. The characteristics and anatomic distribution of lesions that cause reversed vein graft failure: a five-year prospective study. J Vasc Surg 1993;17:195-206.
-
(1993)
J Vasc Surg
, vol.17
, pp. 195-206
-
-
Mills, J.L.1
Fujitani, R.M.2
Taylor, S.M.3
-
10
-
-
0028813945
-
The origin of infrainguinal vein graft stenosis: A prospective study based on duplex surveillance
-
Mills JL, Bandyk DF, Gahtan V, Esses GE. The origin of infrainguinal vein graft stenosis: a prospective study based on duplex surveillance. J Vasc Surg 1995;21:16-25.
-
(1995)
J Vasc Surg
, vol.21
, pp. 16-25
-
-
Mills, J.L.1
Bandyk, D.F.2
Gahtan, V.3
Esses, G.E.4
-
11
-
-
0027229168
-
Mechanisms of vein graft failure
-
Mills JL. Mechanisms of vein graft failure. Semin Vasc Surg 1993;6:78-90.
-
(1993)
Semin Vasc Surg
, vol.6
, pp. 78-90
-
-
Mills, J.L.1
-
12
-
-
0026346292
-
Color-flow duplex criteria for grading stenosis in infra-inguinal vein grafts
-
Buth J, Disselhoff B, Sommeling C, Stam L. Color-flow duplex criteria for grading stenosis in infra-inguinal vein grafts. J Vasc Surg 1991;14:716-28.
-
(1991)
J Vasc Surg
, vol.14
, pp. 716-728
-
-
Buth, J.1
Disselhoff, B.2
Sommeling, C.3
Stam, L.4
-
13
-
-
0027308701
-
Essentials of graft surveillance
-
Bandyk DF. Essentials of graft surveillance. Semin Vasc Surg 1993;6:92-102.
-
(1993)
Semin Vasc Surg
, vol.6
, pp. 92-102
-
-
Bandyk, D.F.1
-
14
-
-
0024207109
-
Detection and grading of femorodistal vein graft stenosis: Duplex velocity measurements compared with angiography
-
Grigg MJ, Nicolaides AN, Wolfe JHN. Detection and grading of femorodistal vein graft stenosis: duplex velocity measurements compared with angiography. J Vasc Surg 1988;8:661-6.
-
(1988)
J Vasc Surg
, vol.8
, pp. 661-666
-
-
Grigg, M.J.1
Nicolaides, A.N.2
Wolfe, J.H.N.3
-
15
-
-
0027477122
-
Impact of a color flow duplex surveillance on infrainguinal vein graft patencu: A five year experience
-
Idu MM, Blankensteijn JD, de Gier Pm, Truyen E, Buth J. Impact of a color flow duplex surveillance on infrainguinal vein graft patencu: a five year experience. J Vasc Surg 1993;17:42-53.
-
(1993)
J Vasc Surg
, vol.17
, pp. 42-53
-
-
Idu, M.M.1
Blankensteijn, J.D.2
De Gier, P.M.3
Truyen, E.4
Buth, J.5
-
16
-
-
0030892370
-
Prospective validation of threshold criteria for intervention in infrainguinal vein grafts undergoing surveillance
-
Westerband A, Mills JL, Kistler S, Berman SS, Hunter GC, Marek JM. Prospective validation of threshold criteria for intervention in infrainguinal vein grafts undergoing surveillance. Ann Vasc Surg 1997;11:44-8.
-
(1997)
Ann Vasc Surg
, vol.11
, pp. 44-48
-
-
Westerband, A.1
Mills, J.L.2
Kistler, S.3
Berman, S.S.4
Hunter, G.C.5
Marek, J.M.6
-
17
-
-
0029118902
-
The value of pre-discharge duplex scanning in infrainguinal graft surveillance
-
Wilson YG, Davies AH, Carrie IC, McGrath C, Morgan M, Baird RN, et al. The value of pre-discharge duplex scanning in infrainguinal graft surveillance. Eur J Endovasc Surg 1995;10:237-42.
-
(1995)
Eur J Endovasc Surg
, vol.10
, pp. 237-242
-
-
Wilson, Y.G.1
Davies, A.H.2
Carrie, I.C.3
McGrath, C.4
Morgan, M.5
Baird, R.N.6
-
19
-
-
0035102190
-
Follow-up of valves in saphenous vein bypass pass grafts with duplex ultrasonography
-
Vesti BR, Primozich J, Bergelin RO, Strandness E Jr. Follow-up of valves in saphenous vein bypass pass grafts with duplex ultrasonography. J Vasc Surg 2001;33:369-74.
-
(2001)
J Vasc Surg
, vol.33
, pp. 369-374
-
-
Vesti, B.R.1
Primozich, J.2
Bergelin, R.O.3
Strandness E., Jr.4
-
20
-
-
0034816813
-
Infrainguinal vein graft surveillance: How and when
-
Mills JM. Infrainguinal vein graft surveillance: how and when. Semin Vasc Surg 2001;14:169-76.
-
(2001)
Semin Vasc Surg
, vol.14
, pp. 169-176
-
-
Mills, J.M.1
-
21
-
-
0029133761
-
Duplex criteria for predicting progression of vein graft lesions: Which stenoses can be followed?
-
Gahtan V, Payne LP, Roper LD, Mills JL, Jackson MM, Bandyk DF. Duplex criteria for predicting progression of vein graft lesions: which stenoses can be followed? J Vasc Technol 1995;19:211-5.
-
(1995)
J Vasc Technol
, vol.19
, pp. 211-215
-
-
Gahtan, V.1
Payne, L.P.2
Roper, L.D.3
Mills, J.L.4
Jackson, M.M.5
Bandyk, D.F.6
-
22
-
-
0034234933
-
An economic appraisal of lower extremity bypass maintenance
-
Wixon CL, Mills JL, Westerband A, Hughes JD, Ihnat DM. An economic appraisal of lower extremity bypass maintenance. J Vasc Surg 2000;32:1-12.
-
(2000)
J Vasc Surg
, vol.32
, pp. 1-12
-
-
Wixon, C.L.1
Mills, J.L.2
Westerband, A.3
Hughes, J.D.4
Ihnat, D.M.5
|