메뉴 건너뛰기




Volumn 37, Issue 3, 2003, Pages 690-692

Delayed neurologic deficit after endovascular abdominal aortic aneurysm repair

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; AGED; ANEURYSM SURGERY; ANGIOGRAPHY; ARTERY OCCLUSION; ARTICLE; CASE REPORT; CEREBROSPINAL FLUID DRAINAGE; EMBOLISM; ENDOVASCULAR SURGERY; HUMAN; INTERNAL ILIAC ARTERY; MALE; NEUROLOGICAL COMPLICATION; PARAPLEGIA; PRIORITY JOURNAL; SPINAL CORD ISCHEMIA;

EID: 0037344295     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2003.161     Document Type: Article
Times cited : (24)

References (13)
  • 1
    • 0027195290 scopus 로고
    • A second look at the etiology of spinal cord damage in surgery of the abdominal aorta
    • Szilagyi DE. A second look at the etiology of spinal cord damage in surgery of the abdominal aorta. J Vasc Surg 1993;17:1111-3.
    • (1993) J Vasc Surg , vol.17 , pp. 1111-1113
    • Szilagyi, D.E.1
  • 2
    • 0027314416 scopus 로고
    • Spinal cord ischemia after abdominal aortic procedures: Is previous colectomy a risk factor?
    • Salam AA, Sholkamy SM, Chaikof EL. Spinal cord ischemia after abdominal aortic procedures: Is previous colectomy a risk factor? J Vasc Surg 1993;17:1108-10.
    • (1993) J Vasc Surg , vol.17 , pp. 1108-1110
    • Salam, A.A.1    Sholkamy, S.M.2    Chaikof, E.L.3
  • 3
    • 0032843726 scopus 로고    scopus 로고
    • Spinal cord ischemia after abdominal aortic operation: Is it preventable?
    • Rosenthal D. Spinal cord ischemia after abdominal aortic operation: Is it preventable? J Vasc Surg 1999;30:391-7.
    • (1999) J Vasc Surg , vol.30 , pp. 391-397
    • Rosenthal, D.1
  • 4
    • 0032972728 scopus 로고    scopus 로고
    • AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial
    • Zarins CK, White RA, Schwarten D, Kinney E, Diethrich EB, et al. AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial. J Vasc Surg 1999;29:292-308.
    • (1999) J Vasc Surg , vol.29 , pp. 292-308
    • Zarins, C.K.1    White, R.A.2    Schwarten, D.3    Kinney, E.4    Diethrich, E.B.5
  • 5
    • 0026327676 scopus 로고
    • Ischemic injury to the spinal cord or lumbosacral plexus after aorto-iliac reconstruction
    • Gloviczki P, Cross SA, Stanson AW, Carmichael SW, Bower TC, et al. Ischemic injury to the spinal cord or lumbosacral plexus after aorto-iliac reconstruction. Am J Surg 1991;162:131-6.
    • (1991) Am J Surg , vol.162 , pp. 131-136
    • Gloviczki, P.1    Cross, S.A.2    Stanson, A.W.3    Carmichael, S.W.4    Bower, T.C.5
  • 7
    • 0035145630 scopus 로고    scopus 로고
    • Lower extremity paraparesis or paraplegia subsequent to endovascular management of abdominal aortic aneurysms
    • Rockman CB, Riles TS, Landis R. Lower extremity paraparesis or paraplegia subsequent to endovascular management of abdominal aortic aneurysms. J Vasc Surg 2001;33:178-80.
    • (2001) J Vasc Surg , vol.33 , pp. 178-180
    • Rockman, C.B.1    Riles, T.S.2    Landis, R.3
  • 8
    • 0036353491 scopus 로고    scopus 로고
    • Late complication of aortoiliac stent placement: Atheroembolization of the lower extremities
    • Lin PH, Bush RL, Conklin BS, Chen C, Weiss VJ, et al. Late complication of aortoiliac stent placement: Atheroembolization of the lower extremities. J Surg Res 2002;103:153-9.
    • (2002) J Surg Res , vol.103 , pp. 153-159
    • Lin, P.H.1    Bush, R.L.2    Conklin, B.S.3    Chen, C.4    Weiss, V.J.5
  • 9
    • 0033022938 scopus 로고    scopus 로고
    • Rectum and sigmoid colon necrosis due to cholesterol embolization after implantation of an aortic stent-graft
    • Jaeger HJ, Mathias KD, Gissler HM, Neumann G, Walther LD. Rectum and sigmoid colon necrosis due to cholesterol embolization after implantation of an aortic stent-graft. J Vasc Interv Radiol 1999;10:751-5.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 751-755
    • Jaeger, H.J.1    Mathias, K.D.2    Gissler, H.M.3    Neumann, G.4    Walther, L.D.5
  • 10
    • 0031044379 scopus 로고    scopus 로고
    • Ultrasound-based quantification of emboli during conventional and endovascular aneurysm repair
    • Thompson MM, Smith J, Naylor AR, Nasim A, Sayers RD, et al. Ultrasound-based quantification of emboli during conventional and endovascular aneurysm repair. J Endovasc Surg 1997;4:33-8.
    • (1997) J Endovasc Surg , vol.4 , pp. 33-38
    • Thompson, M.M.1    Smith, J.2    Naylor, A.R.3    Nasim, A.4    Sayers, R.D.5
  • 12
    • 0030777474 scopus 로고    scopus 로고
    • Observations on delayed neurologic deficit after thoracoabdominal aortic aneurysm repair
    • Sari HJ, Miller CC III, Azizzadeh A, Iliopoulos DC. Observations on delayed neurologic deficit after thoracoabdominal aortic aneurysm repair. J Vasc Surg 1997;26:616-22.
    • (1997) J Vasc Surg , vol.26 , pp. 616-622
    • Sari, H.J.1    Miller C.C. III2    Azizzadeh, A.3    Iliopoulos, D.C.4
  • 13
    • 0036628788 scopus 로고    scopus 로고
    • Spinal cord ischemia following endovascular repair of an infrarenal aortic aneurysm
    • Garcia ND, Tehrani H, Morasch M, Pearce W, Matsumura J. Spinal cord ischemia following endovascular repair of an infrarenal aortic aneurysm. Ann Vasc Surg 2002;16:509-12.
    • (2002) Ann Vasc Surg , vol.16 , pp. 509-512
    • Garcia, N.D.1    Tehrani, H.2    Morasch, M.3    Pearce, W.4    Matsumura, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.