Errors in measuring blood gases in the intensive care unit: Effect of delay in estimation

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTERIAL GAS; ARTICLE; BLOOD GAS ANALYSIS; CARBON DIOXIDE TENSION; CORRELATION ANALYSIS; INFORMATION PROCESSING; INTENSIVE CARE UNIT; LABORATORY TEST; MEASUREMENT; MEDICAL DOCUMENTATION; OXYGEN SATURATION; OXYGEN TENSION; PULSE OXIMETER; ROOM TEMPERATURE; STORAGE; TEMPERATURE SENSITIVITY;

EID: 0037344245     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1053/jcrc.2003.YJCRC7     Document Type: Article
Times cited : (25)

References (5)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0029078722 scopus 로고
    • Sending blood gas specimens through pressurised transport tube systems exaggerates the error in oxygen tension measurements created by the presence of air bubbles
    • McKane MH. Southorn PA, Santrach PJ, et al: Sending blood gas specimens through pressurised transport tube systems exaggerates the error in oxygen tension measurements created by the presence of air bubbles. Anesth Analg 81:179-182, 1995
    • (1995) Anesth Analg , vol.81 , pp. 179-182
    • McKane, M.H.1    Southorn, P.A.2    Santrach, P.J.3
  • 3
    • 0020960742 scopus 로고
    • Too much heparin: Possible source of error in blood gas analysis
    • Hutchison AS, Ralston SH, Dryburgh FJ, et al: Too much heparin: Possible source of error in blood gas analysis. BMJ 287:1131-1132, 1983
    • (1983) BMJ , vol.287 , pp. 1131-1132
    • Hutchison, A.S.1    Ralston, S.H.2    Dryburgh, F.J.3
  • 4
    • 17644432249 scopus 로고
    • A source of error in determination of blood gases
    • Mellor LD, Innanen VT: A source of error in determination of blood gases. Clin Chem 29:395, 1983
    • (1983) Clin Chem , vol.29 , pp. 395
    • Mellor, L.D.1    Innanen, V.T.2
  • 5
    • 0020060661 scopus 로고
    • Blood gas analysis: Effect of air bubbles in syringe and delay in estimation
    • Biswas CK, Ramos JM, Agroyannis B, et al: Blood gas analysis: Effect of air bubbles in syringe and delay in estimation. BMJ 284:923-927, 1982
    • (1982) BMJ , vol.284 , pp. 923-927
    • Biswas, C.K.1    Ramos, J.M.2    Agroyannis, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.