Volumn 35, Issue 1, 2003, Pages 24-27

Comparison of blood gas and electrolyte test results from the Gem-Premier and the ABL-70 versus a conventional laboratory analyzer

Author keywords

Blood gas analyzer; Cardiopulmonary bypass; Point of care testing

Indexed keywords

BASE; BICARBONATE; CALCIUM ION; POTASSIUM; SODIUM;

EID: 0037339866     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0019770453 scopus 로고
    • Continuous monitoring of blood oxygen saturation during extracorporeal circulation
    • Iatridis A, Heinemann S, DeRocher R, Osborn R. Continuous monitoring of blood oxygen saturation during extracorporeal circulation. J Extra Corp Tech. 1981;13:233-6.
    • (1981) J Extra Corp Tech , vol.13 , pp. 233-236
    • Iatridis, A.1    Heinemann, S.2    DeRocher, R.3    Osborn, R.4
  • 5
    • 0012453132 scopus 로고
    • Clinical evaluation of Cardiomet 4000 continuous on-line blood gas analyzer
    • Basha JW, Sternlieb JJ, Bjork VO, et al. Clinical evaluation of Cardiomet 4000 continuous on-line blood gas analyzer. Proc Am Soc Extra Corp Tech. 1988;48-51.
    • (1988) Proc Am Soc Extra Corp Tech , pp. 48-51
    • Basha, J.W.1    Sternlieb, J.J.2    Bjork, V.O.3
  • 7
    • 0033758493 scopus 로고    scopus 로고
    • The effects of continuous blood gas monitoring during cardiopulmonary bypass: A prospective, randomized study - Part 1
    • Trowbridge CC, Vasquez M, Stammers AH, et al. The effects of continuous blood gas monitoring during cardiopulmonary bypass: A prospective, randomized study - Part 1. J Extra Corp Tech. 2000;3:120-8.
    • (2000) J Extra Corp Tech , vol.3 , pp. 120-128
    • Trowbridge, C.C.1    Vasquez, M.2    Stammers, A.H.3
  • 8
    • 0033762621 scopus 로고    scopus 로고
    • The effects of continuous blood gas monitoring during cardiopulmonary bypass: A prospective, randomized study - Part 2
    • Trowbridge CC, Vasquez M, Stammers AH, et al. The effects of continuous blood gas monitoring during cardiopulmonary bypass: A prospective, randomized study - Part 2. J Extra Corp Tech. 2000;3:129-137.
    • (2000) J Extra Corp Tech , vol.3 , pp. 129-137
    • Trowbridge, C.C.1    Vasquez, M.2    Stammers, A.H.3
  • 9
    • 0012431568 scopus 로고
    • Clinical experience with a new portable blood gas and electrolyte analyzer for us during cardiopulmonary bypass
    • Hill AG, Enzer S, Marino JA, et al. Clinical experience with a new portable blood gas and electrolyte analyzer for us during cardiopulmonary bypass. Proc Am Acad Cardiovasc Perfusion. 1987;8:45-51.
    • (1987) Proc Am Acad Cardiovasc Perfusion , vol.8 , pp. 45-51
    • Hill, A.G.1    Enzer, S.2    Marino, J.A.3
  • 10
    • 0027172643 scopus 로고
    • Comparison of blood gas and electrolyte test results from the Gem-Stat and CDI-300 vs. a conventional laboratory analyzer
    • Walton HG, Duvall TB, Van den Hout J, et al. Comparison of blood gas and electrolyte test results from the Gem-Stat and CDI-300 vs. a conventional laboratory analyzer. J Extra Corp Tech. 1993;2:53-7.
    • (1993) J Extra Corp Tech , vol.2 , pp. 53-57
    • Walton, H.G.1    Duvall, T.B.2    Van den Hout, J.3
  • 11
    • 0033946486 scopus 로고    scopus 로고
    • Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for point of care testing
    • Chance JJ, Li DJ, Sokoll LJ, et al. Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for point of care testing. Crit Care Med. 2000;28:2081-5.
    • (2000) Crit Care Med , vol.28 , pp. 2081-2085
    • Chance, J.J.1    Li, D.J.2    Sokoll, L.J.3
  • 12
    • 0012422304 scopus 로고    scopus 로고
    • An evaluation of point of care blood gas analysers
    • Abstract 14
    • St-Louis P, Legault D. An evaluation of point of care blood gas analysers. Clin Chem Suppl. 2000;46:A5 (Abstract 14).
    • (2000) Clin Chem Suppl , vol.46
    • St-Louis, P.1    Legault, D.2
  • 13
    • 0032954797 scopus 로고    scopus 로고
    • Portable blood gas and electrolyte analyzer evaluated in multiinstitutional study
    • Lindemans J, Hoefkens P, van Kessel AL, et al. Portable blood gas and electrolyte analyzer evaluated in multiinstitutional study. Clin Chem. 1999;45:111-7.
    • (1999) Clin Chem , vol.45 , pp. 111-117
    • Lindemans, J.1    Hoefkens, P.2    Van Kessel, A.L.3
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lacent. 1986;1:307- 10.
    • (1986) Lacent , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.