메뉴 건너뛰기




Volumn 26, Issue 2, 2003, Pages 205-213

X-ray investigation of a domestic refrigerator. Observations at 25°C ambient temperature

Author keywords

Circuit; Domestic refrigerator; Operation; Refrigerant; Research; X ray

Indexed keywords

ACOUSTIC NOISE; COOLING SYSTEMS; DEFROSTING; DRYERS (EQUIPMENT); EVAPORATORS; INTAKE SYSTEMS; X RAY ANALYSIS;

EID: 0037332971     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0140-7007(02)00059-2     Document Type: Article
Times cited : (16)

References (14)
  • 1
    • 0029700604 scopus 로고
    • Cycling and quasi-steady behavior of a refrigerator
    • Krause P.E., Bullard C.W. Cycling and quasi-steady behavior of a refrigerator. ASHRAE Transactions. 102:1994;1061-1070.
    • (1994) ASHRAE Transactions , vol.102 , pp. 1061-1070
    • Krause, P.E.1    Bullard, C.W.2
  • 2
    • 0030707212 scopus 로고    scopus 로고
    • An experimental analysis of cycling losses in domestic refrigerator freezers
    • Coulter W.H., Bullard C.W. An experimental analysis of cycling losses in domestic refrigerator freezers. ASHRAE Transactions. 103:1997;587-596.
    • (1997) ASHRAE Transactions , vol.103 , pp. 587-596
    • Coulter, W.H.1    Bullard, C.W.2
  • 3
    • 0000385914 scopus 로고
    • Factors contributing to refrigerator cycling losses
    • Rubas P.J., Bullard C.W. Factors contributing to refrigerator cycling losses. Int J Refrigertation. 18:1995;168-176.
    • (1995) Int J Refrigertation , vol.18 , pp. 168-176
    • Rubas, P.J.1    Bullard, C.W.2
  • 5
  • 6
    • 0012010822 scopus 로고
    • Personal communication. ACRC (Air Conditioning and Refrigeration Center), University of Illinois at Urbana-Champaign
    • Porter K.J. Personal communication. ACRC (Air Conditioning and Refrigeration Center), University of Illinois at Urbana-Champaign; 1994.
    • (1994)
    • Porter, K.J.1
  • 7
    • 0003885707 scopus 로고    scopus 로고
    • Technical Reports TR-179, ACRC (Air Conditioning and Refrigeration Center), University of Illinois at Urbana-Champaign
    • Shedd T.A., Newell T.A. Characteristics of the liquid film in horizontal two-phase flow. Technical Reports TR-179, ACRC (Air Conditioning and Refrigeration Center), University of Illinois at Urbana-Champaign; 2001.
    • (2001) Characteristics of the liquid film in horizontal two-phase flow
    • Shedd, T.A.1    Newell, T.A.2
  • 9
    • 0029324983 scopus 로고    scopus 로고
    • An experimental investigation of entrained liquid carry-over from a serpentine evaporator
    • Barnhart J.S., Peters J.E. An experimental investigation of entrained liquid carry-over from a serpentine evaporator. Int J Refrigeration. 18(3):1996;343-354.
    • (1996) Int J Refrigeration , vol.18 , Issue.3 , pp. 343-354
    • Barnhart, J.S.1    Peters, J.E.2
  • 12
    • 0002743448 scopus 로고
    • Numerical and experimental studies on adiabatic and nonadiabatic capillary tubes with HFC-134a
    • Purdue University
    • Dirik E., Inan C., Tanes M.Y. Numerical and experimental studies on adiabatic and nonadiabatic capillary tubes with HFC-134a. Proceeding of International Refrigeration Confrence, Purdue University; 1994.
    • (1994) Proceeding of International Refrigeration Confrence
    • Dirik, E.1    Inan, C.2    Tanes, M.Y.3
  • 13
    • 0032306953 scopus 로고    scopus 로고
    • A generalized performance prediction method for adiabatic capillary tubes
    • Bittle R.R., Wolf D.A., Pate M.B. A generalized performance prediction method for adiabatic capillary tubes. ASHRAE Transactions; 1998.
    • (1998) ASHRAE Transactions
    • Bittle, R.R.1    Wolf, D.A.2    Pate, M.B.3
  • 14
    • 0002575170 scopus 로고
    • An experimental evaluation of adiabatic capillary tube performance for HFC-134a and CFC-12
    • Baltimore, MD
    • Wijaya H. An experimental evaluation of adiabatic capillary tube performance for HFC-134a and CFC-12. Int. CFCand Halon Alternatives Conference, Baltimore, MD; 1991.
    • (1991) Int. CFCand Halon Alternatives Conference
    • Wijaya, H.1