메뉴 건너뛰기




Volumn 31, Issue 1, 2003, Pages 80-86

A prospective clinical audit of central venous catheter use and complications in 1000 consecutive patients

Author keywords

Central venous catheter; Complications; Cost; Equipment; Pulmonary artery catheter; Usage patterns; Vascular perforation

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTERY CATHETER; ARTERY CATHETERIZATION; ARTERY PERFORATION; ARTICLE; BLOOD VESSEL PERFORATION; CATHETER INFECTION; CENTRAL VENOUS CATHETER; CENTRAL VENOUS CATHETERIZATION; CHILD; CONTROLLED STUDY; CORRELATION ANALYSIS; COST; FATALITY; FEMALE; HEALTH CARE NEED; HEART INJURY; HEART RIGHT ATRIUM; HUMAN; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; MEDICAL AUDIT; PATIENT CARE; POSTOPERATIVE COMPLICATION; PROSPECTIVE STUDY; PULMONARY ARTERY; RISK ASSESSMENT; SEPSIS; STATISTICAL ANALYSIS;

EID: 0037325883     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x0303100116     Document Type: Article
Times cited : (18)

References (35)
  • 1
    • 0018343876 scopus 로고
    • Fatal pulmonary hemorrhage after use of the flow-directed balloon-tipped catheter
    • Pape LA, Haffajee CI, Markis JE et al. Fatal pulmonary hemorrhage after use of the flow-directed balloon-tipped catheter. Ann Intern Med 1979; 90:344-347.
    • (1979) Ann. Intern. Med. , vol.90 , pp. 344-347
    • Pape, L.A.1    Haffajee, C.I.2    Markis, J.E.3
  • 2
    • 0028213997 scopus 로고
    • Depth of central venous catheterization-an audit of practice in a cardiac surgical unit
    • Rutherford JS, Merry AF, Occleshaw CJ. Depth of central venous catheterization-an audit of practice in a cardiac surgical unit. Anaesth Intensive Care 1994; 22:267-271.
    • (1994) Anaesth. Intensive Care , vol.22 , pp. 267-271
    • Rutherford, J.S.1    Merry, A.F.2    Occleshaw, C.J.3
  • 3
    • 84941817891 scopus 로고
    • Central vein catheterization-failure and complication rates by three percutaneous approaches
    • Sznajder JI, Zveibil FR, Bitterman H, Weiner P, Bursztein S. Central vein catheterization-failure and complication rates by three percutaneous approaches. Arch Intern Med 1986; 146:259-261.
    • (1986) Arch. Intern. Med. , vol.146 , pp. 259-261
    • Sznajder, J.I.1    Zveibil, F.R.2    Bitterman, H.3    Weiner, P.4    Bursztein, S.5
  • 4
    • 0025834756 scopus 로고
    • Placement and complications of monitoring catheters
    • Purdue GF, Hunt JL. Placement and complications of monitoring catheters. Surg Clin Nth Am 1991; 71:723-731.
    • (1991) Surg. Clin. Nth. Am. , vol.71 , pp. 723-731
    • Purdue, G.F.1    Hunt, J.L.2
  • 5
    • 0013409635 scopus 로고
    • The technique of managing central venous lines
    • Sitzmann JV. The technique of managing central venous lines. J Crit Illness 1986; 1:50-55.
    • (1986) J. Crit. Illness , vol.1 , pp. 50-55
    • Sitzmann, J.V.1
  • 7
    • 0036163509 scopus 로고    scopus 로고
    • Central venous catheter use: Mechanical complications
    • Polderman KH, Girbes ARJ. Central venous catheter use-part 1: mechanical complications. Intensive Care Med 2002; 28:1-17.
    • (2002) Intensive Care Med. , vol.28 , Issue.PART 1 , pp. 1-17
    • Polderman, K.H.1    Girbes, A.R.J.2
  • 8
    • 0036161445 scopus 로고    scopus 로고
    • Central venous catheter use: Infectious complications
    • Polderman KH, Girbes ARJ. Central venous catheter use-part 2: infectious complications. Intensive Care Med 2002; 28:18-28.
    • (2002) Intensive Care Med. , vol.28 , Issue.PART 2 , pp. 18-28
    • Polderman, K.H.1    Girbes, A.R.J.2
  • 10
    • 0013455136 scopus 로고
    • Invited commentary
    • Burri C. Invited commentary. World J Surg 1982; 6:142-143.
    • (1982) World J. Surg. , vol.6 , pp. 142-143
    • Burri, C.1
  • 11
    • 0021701875 scopus 로고
    • Cardiac tamponade caused by pulmonary artery perforation after central venous catheterization
    • Hunt LB, Olshansky B, Hiratzka LF. Cardiac tamponade caused by pulmonary artery perforation after central venous catheterization. J Parenter Enteral Nutr 1984; 8:711-713.
    • (1984) J. Parenter Enteral Nutr. , vol.8 , pp. 711-713
    • Hunt, L.B.1    Olshansky, B.2    Hiratzka, L.F.3
  • 12
    • 0020323151 scopus 로고
    • Pericardial tamponade caused by central venous catheters
    • Krog M, Berggren L, Brodin M, Wickbom G. Pericardial tamponade caused by central venous catheters. World J Surg 1982; 6:138-143.
    • (1982) World J. Surg. , vol.6 , pp. 138-143
    • Krog, M.1    Berggren, L.2    Brodin, M.3    Wickbom, G.4
  • 13
    • 0023025925 scopus 로고
    • Cardiac tamponade from central venous catheterization
    • Karnauchow PN. Cardiac tamponade from central venous catheterization. Can Med Assoc J 1986; 135:1145-1147.
    • (1986) Can. Med. Assoc. J. , vol.135 , pp. 1145-1147
    • Karnauchow, P.N.1
  • 14
    • 0016851514 scopus 로고
    • Cardiac tamponade and central venous catheters
    • Greenall MJ, Blewitt RW, McMahon MJ. Cardiac tamponade and central venous catheters. BMJ 1975; 2:595-597.
    • (1975) BMJ , vol.2 , pp. 595-597
    • Greenall, M.J.1    Blewitt, R.W.2    McMahon, M.J.3
  • 15
    • 0024582380 scopus 로고
    • Central venous catheter vascular erosions-diagnosis and clinical course
    • Ellis LM, Vogel SB, Copeland EM. Central venous catheter vascular erosions-diagnosis and clinical course. Ann Surg 1989; 209:475-478.
    • (1989) Ann. Surg. , vol.209 , pp. 475-478
    • Ellis, L.M.1    Vogel, S.B.2    Copeland, E.M.3
  • 16
    • 0031951427 scopus 로고    scopus 로고
    • Depth of central venous catheter insertion in adults-an audit and assessment of a technique to improve tip position
    • Chalkiadis GA, Goucke CR. Depth of central venous catheter insertion in adults-an audit and assessment of a technique to improve tip position. Anaesth Intensive Care 1998; 26:61-66.
    • (1998) Anaesth. Intensive Care , vol.26 , pp. 61-66
    • Chalkiadis, G.A.1    Goucke, C.R.2
  • 17
    • 0344522064 scopus 로고
    • Correct position of a central venous line
    • Anon
    • Anon. Correct position of a central venous line. N Z Med J 1993; 106:370-371.
    • (1993) N. Z. Med. J. , vol.106 , pp. 370-371
  • 18
    • 0033395594 scopus 로고    scopus 로고
    • A prospective randomized clinical assessment of a new pigtail central venous catheter in comparison with standard alternatives
    • Merry AF, Webster CS, Van Cotthem IC, Holland RL, Beca JS, Middleton NG. A prospective randomized clinical assessment of a new pigtail central venous catheter in comparison with standard alternatives. Anaesth Intensive Care 1999; 27:639-645.
    • (1999) Anaesth. Intensive Care , vol.27 , pp. 639-645
    • Merry, A.F.1    Webster, C.S.2    Van Cotthem, I.C.3    Holland, R.L.4    Beca, J.S.5    Middleton, N.G.6
  • 19
    • 0025945916 scopus 로고
    • Risk factors for central venous catheter-related vascular erosions
    • Mukau L, Talamini MA, Sitzmann JV. Risk factors for central venous catheter-related vascular erosions. J Parenter Enteral Nutr 1991; 15:513-516.
    • (1991) J. Parenter Enteral Nutr. , vol.15 , pp. 513-516
    • Mukau, L.1    Talamini, M.A.2    Sitzmann, J.V.3
  • 20
    • 0030183205 scopus 로고    scopus 로고
    • Guideline for prevention of intravascular-device-related infections
    • the Hospital Infection Control Practices Advisory Committee
    • Pearson ML, the Hospital Infection Control Practices Advisory Committee. Guideline for prevention of intravascular-device-related infections. Infect Control Hosp Epidemiol 1996; 17:438-473.
    • (1996) Infect Control Hosp. Epidemiol. , vol.17 , pp. 438-473
    • Pearson, M.L.1
  • 21
    • 0023550859 scopus 로고
    • Catheter-induced pulmonary artery perforation-pathologic and pathogenic features
    • Fraser RS. Catheter-induced pulmonary artery perforation-pathologic and pathogenic features. Hum Pathol 1987; 18:1246-1251.
    • (1987) Hum. Pathol. , vol.18 , pp. 1246-1251
    • Fraser, R.S.1
  • 22
    • 0021273264 scopus 로고
    • A review of pulmonary artery catheterization in 6,245 patients
    • Shah KB, Rao TLK, Laughlin S, El-Etr AA. A review of pulmonary artery catheterization in 6,245 patients. Anesthesiology 1984; 61:271-275.
    • (1984) Anesthesiology , vol.61 , pp. 271-275
    • Shah, K.B.1    Rao, T.L.K.2    Laughlin, S.3    El-Etr, A.A.4
  • 23
    • 0035665732 scopus 로고    scopus 로고
    • Management of catheter-induced pulmonary artery perforation-a rare complication in cardiovascular operations
    • Sirivella S, Gielchinsky I, Parsonnet V. Management of catheter-induced pulmonary artery perforation-a rare complication in cardiovascular operations. Ann Thorac Surg 2001; 72:2056-2059.
    • (2001) Ann. Thorac. Surg. , vol.72 , pp. 2056-2059
    • Sirivella, S.1    Gielchinsky, I.2    Parsonnet, V.3
  • 24
    • 0030010016 scopus 로고    scopus 로고
    • Swan-Ganz catheter induced pulmonary artery perforation during cardiac surgery concerning two cases
    • Sekkal S, Cornu E, Christidès C et al. Swan-Ganz catheter induced pulmonary artery perforation during cardiac surgery concerning two cases. J Cardiovasc Surg 1996; 37:313-317.
    • (1996) J. Cardiovasc. Surg. , vol.37 , pp. 313-317
    • Sekkal, S.1    Cornu, E.2    Christidès, C.3
  • 26
    • 0019452928 scopus 로고
    • Catheter-induced pulmonary artery perforation-mechanisms, management, and modifications
    • Barash PG, Nardi D, Hammond G et al. Catheter-induced pulmonary artery perforation-mechanisms, management, and modifications. J Thorac Cardiovasc Surg 1981; 82:5-12.
    • (1981) J. Thorac. Cardiovasc. Surg. , vol.82 , pp. 5-12
    • Barash, P.G.1    Nardi, D.2    Hammond, G.3
  • 27
    • 0025991086 scopus 로고
    • Increased pulmonary artery perforating potential of pulmonary artery catheters during hypothermia
    • Cohen JA, Blackshear RH, Gravenstein N, Woeste J. Increased pulmonary artery perforating potential of pulmonary artery catheters during hypothermia. J Cardiothorac Vasc Anesth 1991; 5:234-236.
    • (1991) J. Cardiothorac. Vasc. Anesth. , vol.5 , pp. 234-236
    • Cohen, J.A.1    Blackshear, R.H.2    Gravenstein, N.3    Woeste, J.4
  • 28
    • 0035908623 scopus 로고    scopus 로고
    • The pulmonary artery catheter-friend, foe, or accomplice?
    • Editorial
    • Dalen JE. The pulmonary artery catheter-friend, foe, or accomplice? Editorial. JAMA 2001; 286:348-350.
    • (2001) JAMA , vol.286 , pp. 348-350
    • Dalen, J.E.1
  • 29
    • 0031017937 scopus 로고    scopus 로고
    • Pulmonary artery flotation catheters-a statement by the American College of Chest Physicians and the American Thoracic Society
    • Editorial
    • Chernow B. Pulmonary artery flotation catheters-a statement by the American College of Chest Physicians and the American Thoracic Society. Editorial. Chest 1997; 111:261-262.
    • (1997) Chest , vol.111 , pp. 261-262
    • Chernow, B.1
  • 30
    • 0030111212 scopus 로고    scopus 로고
    • Central venous catheter-related infections-a review
    • Adal KA, Farr BM. Central venous catheter-related infections-a review. Nutrition 1996; 12:208-213.
    • (1996) Nutrition , vol.12 , pp. 208-213
    • Adal, K.A.1    Farr, B.M.2
  • 31
    • 0034201550 scopus 로고    scopus 로고
    • Scheduled replacement of central venous catheters is not necessary
    • Timsit JF. Scheduled replacement of central venous catheters is not necessary. Infect Control Hosp Epidemiol 2000; 21:371-374.
    • (2000) Infect. Control Hosp. Epidemiol. , vol.21 , pp. 371-374
    • Timsit, J.F.1
  • 33
    • 0023737574 scopus 로고
    • Do multi-lumen catheters increase central venous catheter sepsis compared to single-lumen catheters?
    • Lee RB, Buckner M, Sharp KW. Do multi-lumen catheters increase central venous catheter sepsis compared to single-lumen catheters? J Trauma 1988; 28:1472-1475.
    • (1988) J. Trauma , vol.28 , pp. 1472-1475
    • Lee, R.B.1    Buckner, M.2    Sharp, K.W.3
  • 34
    • 0345384468 scopus 로고    scopus 로고
    • Connecta Multi-flo 5-Way-Suggestions for Use
    • Anon New Jersey, Becton Dickinson & Company
    • Anon. Connecta Multi-flo 5-Way-Suggestions for Use. New Jersey, Becton Dickinson & Company 2000.
    • (2000)
  • 35
    • 0003413171 scopus 로고    scopus 로고
    • To Err Is Human-Building a Safer Health System
    • Institute of Medicine. Washington DC, National Academy Press
    • Institute of Medicine. To Err Is Human-Building a Safer Health System. Washington DC, National Academy Press 2000.
    • (2000)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.