메뉴 건너뛰기




Volumn 89, Issue 1, 2003, Pages 35-43

Biodegradable meniscus refixation devices: A biomechanical study;Réparation méniscale par fixations biodégradables: Étude biomécanique comparative

Author keywords

Cyclic testing; Meniscus; Meniscus repair; Meniscus suture; Suture material

Indexed keywords

ARTICLE; BIODEGRADABILITY; BIOMECHANICS; DEVICE; FRACTURE FIXATION; KNEE MENISCUS; KNEE SURGERY; NONHUMAN; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; SURGICAL TECHNIQUE; SUTURE; SWINE; WEIGHT BEARING;

EID: 0037322590     PISSN: 00351040     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (27)
  • 1
    • 0027430820 scopus 로고
    • Arthroscopic repair of the bucket-handle meniscus. Ten failures in 27 stable knees followed for 3 years
    • ALBRECHT-OLSEN PM, BAK K: Arthroscopic repair of the bucket-handle meniscus. Ten failures in 27 stable knees followed for 3 years. Acta Orthop Scand, 1993, 64, 446-448.
    • (1993) Acta Orthop Scand , vol.64 , pp. 446-448
    • Albrecht-Olsen, P.M.1    Bak, K.2
  • 2
    • 0033628795 scopus 로고    scopus 로고
    • Biofix resorbable meniscus arrow for meniscal ruptures: Results of a 1-year follow-up
    • HUREL C, MERTENS F, VERDONK R: Biofix resorbable meniscus arrow for meniscal ruptures: results of a 1-year follow-up. Knee Surg Sports Traumatol Arthrosc, 2000, 8, 46-52.
    • (2000) Knee Surg Sports Traumatol Arthrosc , vol.8 , pp. 46-52
    • Hurel, C.1    Mertens, F.2    Verdonk, R.3
  • 3
    • 18544407341 scopus 로고    scopus 로고
    • Meniskusrekonstruktionen. Bewährte und innovative verfahren
    • SEIL R, KOHN D: Meniskusrekonstruktionen. Bewährte und innovative Verfahren. Unfallchirurg, 2001, 104, 274-287.
    • (2001) Unfallchirurg , vol.104 , pp. 274-287
    • Seil, R.1    Kohn, D.2
  • 4
    • 0013182905 scopus 로고    scopus 로고
    • Cyclic testing of meniscus sutures
    • SEIL R, RUPP S, KOHN D: Cyclic testing of meniscus sutures. Arthroscopy, 2000, 16, 1-8.
    • (2000) Arthroscopy , vol.16 , pp. 1-8
    • Seil, R.1    Rupp, S.2    Kohn, D.3
  • 5
    • 0029053920 scopus 로고
    • Failure strengths of different meniscal suturing techniques
    • RIMMER MG, NAWANA NS, KEENE GC, PEARCY MJ: Failure strengths of different meniscal suturing techniques. Arthroscopy, 1995, 11, 146-150.
    • (1995) Arthroscopy , vol.11 , pp. 146-150
    • Rimmer, M.G.1    Nawana, N.S.2    Keene, G.C.3    Pearcy, M.J.4
  • 6
    • 0024807219 scopus 로고
    • Meniscus suture techniques: A comparative biomechanical cadaver study
    • KOHN D, SIEBERT W: Meniscus suture techniques: a comparative biomechanical cadaver study. Arthroscopy, 1989, 5, 324-327.
    • (1989) Arthroscopy , vol.5 , pp. 324-327
    • Kohn, D.1    Siebert, W.2
  • 8
    • 0031469372 scopus 로고    scopus 로고
    • Load to failure of common meniscal repair techniques: Effects of suture technique and suture material
    • POST WR, AKERS SR, KISH V: Load to failure of common meniscal repair techniques: effects of suture technique and suture material. Arthroscopy, 1997, 13, 731-736.
    • (1997) Arthroscopy , vol.13 , pp. 731-736
    • Post, W.R.1    Akers, S.R.2    Kish, V.3
  • 9
    • 0030967483 scopus 로고    scopus 로고
    • Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture
    • ALBRECHT-OLSEN P, LIND T, KRISTENSEN G, FALKENBERG B: Failure strength of a new meniscus arrow repair technique: biomechanical comparison with horizontal suture. Arthroscopy, 1997, 13, 183-187.
    • (1997) Arthroscopy , vol.13 , pp. 183-187
    • Albrecht-Olsen, P.1    Lind, T.2    Kristensen, G.3    Falkenberg, B.4
  • 10
    • 0032829819 scopus 로고    scopus 로고
    • Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures
    • BOENISCH UW, FABER KJ, CIARELLI M, STEADMAN JR, ARNOCZKY SP: Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med, 1999, 27, 626-631.
    • (1999) Am J Sports Med , vol.27 , pp. 626-631
    • Boenisch, U.W.1    Faber, K.J.2    Ciarelli, M.3    Steadman, J.R.4    Arnoczky, S.P.5
  • 11
    • 0035084489 scopus 로고    scopus 로고
    • Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study
    • ARNOCZKY SP, LAVAGNINO M: Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study. Am J Sports Med, 2001, 29, 118-123.
    • (2001) Am J Sports Med , vol.29 , pp. 118-123
    • Arnoczky, S.P.1    Lavagnino, M.2
  • 12
  • 13
    • 0035353891 scopus 로고    scopus 로고
    • Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus
    • BECKER R, SCHRODER M, STARKE C, URBACH D, NEBELUNG W: Biomechanical investigations of different meniscal repair implants in comparison with horizontal sutures on human meniscus. Arthroscopy, 2001, 17, 439-444.
    • (2001) Arthroscopy , vol.17 , pp. 439-444
    • Becker, R.1    Schroder, M.2    Starke, C.3    Urbach, D.4    Nebelung, W.5
  • 14
    • 0032729515 scopus 로고    scopus 로고
    • Biomechanical factors in tissue engineered meniscal repair
    • SETTON LA, GUILAK F, HSU EW, VAIL TP: Biomechanical factors in tissue engineered meniscal repair. Clin Orthop, 1999, 367 (suppl), S254-S272.
    • (1999) Clin Orthop , vol.367 , Issue.SUPPL.
    • Setton, L.A.1    Guilak, F.2    Hsu, E.W.3    Vail, T.P.4
  • 15
    • 0032887435 scopus 로고    scopus 로고
    • Broken arrow: A complication of meniscal repair
    • CALDER SJ, MYERS PT: Broken arrow: a complication of meniscal repair. Arthroscopy, 1999, 15, 651-652.
    • (1999) Arthroscopy , vol.15 , pp. 651-652
    • Calder, S.J.1    Myers, P.T.2
  • 16
    • 0032956450 scopus 로고    scopus 로고
    • Failure of a biodegradable meniscal arrow. A case report
    • HUTCHINSON MR, ASH SA: Failure of a biodegradable meniscal arrow. A case report. Am J Sports Med, 1999, 27, 101-103.
    • (1999) Am J Sports Med , vol.27 , pp. 101-103
    • Hutchinson, M.R.1    Ash, S.A.2
  • 17
    • 0033810990 scopus 로고    scopus 로고
    • Biofix arrow appearing as a subcutaneous foreign body
    • OLIVERSON TJ, LINTNER DM: Biofix arrow appearing as a subcutaneous foreign body. Arthroscopy, 2000, 16, 652-655.
    • (2000) Arthroscopy , vol.16 , pp. 652-655
    • Oliverson, T.J.1    Lintner, D.M.2
  • 18
    • 0033780476 scopus 로고    scopus 로고
    • Chondral injury following meniscal repair with a biodegradable implant
    • ANDERSON K, MARX RG, HANNAFIN J, WARREN RF: Chondral injury following meniscal repair with a biodegradable implant. Arthroscopy, 2000, 16, 749-753.
    • (2000) Arthroscopy , vol.16 , pp. 749-753
    • Anderson, K.1    Marx, R.G.2    Hannafin, J.3    Warren, R.F.4
  • 19
    • 0013294980 scopus 로고    scopus 로고
    • Chondral damage after meniscus repair with the use of a bioabsorbable implant
    • sous presse
    • MENETREY J, SEIL R, RUPP S, FRITSCHY D: Chondral damage after meniscus repair with the use of a bioabsorbable implant. Am J Sports Med, sous presse.
    • Am J Sports Med
    • Menetrey, J.1    Seil, R.2    Rupp, S.3    Fritschy, D.4
  • 20
    • 0033780294 scopus 로고    scopus 로고
    • Chondral injury after meniscal repair with bioabsorbable arrows
    • ROSS G, GRABILL J, MCDEVITT E: Chondral injury after meniscal repair with bioabsorbable arrows. Arthroscopy, 2000, 16, 754-756.
    • (2000) Arthroscopy , vol.16 , pp. 754-756
    • Ross, G.1    Grabill, J.2    Mcdevitt, E.3
  • 22
    • 0032827041 scopus 로고    scopus 로고
    • Inflammatory foreign-body reaction to an arthroscopic bioabsorbable meniscal arrow repair
    • MENCHE DS, PHILLIPS GI, PITMAN MI, STEINER GC: Inflammatory foreign-body reaction to an arthroscopic bioabsorbable meniscal arrow repair. Arthroscopy, 1999, 15, 770-772.
    • (1999) Arthroscopy , vol.15 , pp. 770-772
    • Menche, D.S.1    Phillips, G.I.2    Pitman, M.I.3    Steiner, G.C.4
  • 23
    • 0034976148 scopus 로고    scopus 로고
    • Der einfluß verschiedener nahtstärken auf das verhalten von meniskusnähten unter zyklischer zugbelastung
    • SEIL R, RUPP S, JURECKA C, REIN R, KOHN D: Der Einfluß verschiedener Nahtstärken auf das Verhalten von Meniskusnähten unter zyklischer Zugbelastung. Unfallchirurg, 2001, 104, 392-398.
    • (2001) Unfallchirurg , vol.104 , pp. 392-398
    • Seil, R.1    Rupp, S.2    Jurecka, C.3    Rein, R.4    Kohn, D.5
  • 24
    • 0032613738 scopus 로고    scopus 로고
    • The arrow versus horizontal suture in arthroscopic meniscus repair. A prospective randomized study with arthroscopic evaluation
    • ALBRECHT-OLSEN P, KRISTENSEN G, BURGAARD P, JOERGENSEN U, TOERHOLM C: The arrow versus horizontal suture in arthroscopic meniscus repair. A prospective randomized study with arthroscopic evaluation. Knee Surg Sports Traumatol Arthrosc, 1999, 7, 268-273.
    • (1999) Knee Surg Sports Traumatol Arthrosc , vol.7 , pp. 268-273
    • Albrecht-Olsen, P.1    Kristensen, G.2    Burgaard, P.3    Joergensen, U.4    Toerholm, C.5
  • 25
    • 0030915957 scopus 로고    scopus 로고
    • Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study
    • DERVIN GF, DOWNING KJ, KEENE GC, MCBRIDE DG: Failure strengths of suture versus biodegradable arrow for meniscal repair: an in vitro study. Arthroscopy, 1997, 13, 296-300.
    • (1997) Arthroscopy , vol.13 , pp. 296-300
    • Dervin, G.F.1    Downing, K.J.2    Keene, G.C.3    Mcbride, D.G.4
  • 26
    • 0032851819 scopus 로고    scopus 로고
    • Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture
    • SONG EK, LEE KB: Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy, 1999, 15, 726-732.
    • (1999) Arthroscopy , vol.15 , pp. 726-732
    • Song, E.K.1    Lee, K.B.2
  • 27
    • 0013184001 scopus 로고    scopus 로고
    • Primary stability of currently available meniscal repair techniques: An in vitro biomechanical comparison
    • Brussels, June 3-8
    • VANDENNEUCKER H, BELLEMANS J, LABEY L, FABRY G, VAN AUDEKERCKE R: Primary stability of currently available meniscal repair techniques: an in vitro biomechanical comparison. 4th Congress of the EFORT, Brussels, June 3-8, 1999.
    • (1999) 4th Congress of the EFORT
    • Vandenneucker, H.1    Bellemans, J.2    Labey, L.3    Fabry, G.4    Van Audekercke, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.