메뉴 건너뛰기




Volumn 49, Issue 2, 2003, Pages 315-321

In vivo time-resolved quantitative motion mapping of the murine myocardium with phase contrast MRI

Author keywords

Cardiac function; Cardiac motion; Infarction; Mice; MRI; Myocardial velocity; Phase contrast

Indexed keywords

CARDIOLOGY; MAGNETIC RESONANCE IMAGING; MAMMALS;

EID: 0037310199     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10342     Document Type: Article
Times cited : (46)

References (30)
  • 2
    • 0023864999 scopus 로고
    • Functional evaluation of the heart with magnetic resonance imaging
    • Higgins C, Holt W, Pflugfelder P, Sechtem U. Functional evaluation of the heart with magnetic resonance imaging. Magn Reson Med 1988:6:121-139.
    • (1988) Magn Reson Med , vol.6 , pp. 121-139
    • Higgins, C.1    Holt, W.2    Pflugfelder, P.3    Sechtem, U.4
  • 3
  • 4
    • 0023737101 scopus 로고
    • Human heart: Tagging with MR imaging - A method for noninvasive assessment of myocardial motion
    • Zerhouni E, Parish D, Rogers W, Yang A, Shapiro E. Human heart: tagging with MR imaging - a method for noninvasive assessment of myocardial motion. Radiology 1988;169:59-63.
    • (1988) Radiology , vol.169 , pp. 59-63
    • Zerhouni, E.1    Parish, D.2    Rogers, W.3    Yang, A.4    Shapiro, E.5
  • 5
    • 0024307534 scopus 로고
    • Heart wall motion: Improved method of spatial modulation of magnetization for MR imaging
    • Axel L, Dougherty L. Heart wall motion: improved method of spatial modulation of magnetization for MR imaging. Radiology 1989;172:349-350.
    • (1989) Radiology , vol.172 , pp. 349-350
    • Axel, L.1    Dougherty, L.2
  • 7
    • 0002382395 scopus 로고    scopus 로고
    • Quantitative evalutation of regional strain in mice using SPAMM tagging and DENSE
    • ISMRM, Denver
    • Kolandaivelu A, Balaban R. Quantitative evalutation of regional strain in mice using SPAMM tagging and DENSE. In: Proc 8th Annual Meeting, ISMRM, Denver, 2000. p 1610.
    • (2000) Proc 8th Annual Meeting , pp. 1610
    • Kolandaivelu, A.1    Balaban, R.2
  • 8
    • 0036325934 scopus 로고    scopus 로고
    • MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions
    • Epstein F, Yang Z, Gilson W, Berr S, Kramer C, French B. MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions. Magn Reson Med 2002;48:399-403.
    • (2002) Magn Reson Med , vol.48 , pp. 399-403
    • Epstein, F.1    Yang, Z.2    Gilson, W.3    Berr, S.4    Kramer, C.5    French, B.6
  • 9
    • 0021235637 scopus 로고
    • Direct cardiac NMR imaging of heart wall and blood flow velocity
    • van Dijk P. Direct cardiac NMR imaging of heart wall and blood flow velocity. J Comput Assist Tomogr 1984;8:429-436.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 429-436
    • Van Dijk, P.1
  • 10
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant D, Payne J, Firmin D, Longmore D. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J Comput Assist Tomogr 1984;8:588-592.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 588-592
    • Bryant, D.1    Payne, J.2    Firmin, D.3    Longmore, D.4
  • 13
    • 0026182092 scopus 로고
    • Encoding strategies for three-direction phase contrast MR imaging of flow
    • Pelc N, Bernstein M, Shimakawa A, Glover G. Encoding strategies for three-direction phase contrast MR imaging of flow. J Magn Reson Imag 1991;1:405.
    • (1991) J Magn Reson Imag , vol.1 , pp. 405
    • Pelc, N.1    Bernstein, M.2    Shimakawa, A.3    Glover, G.4
  • 14
    • 0026698614 scopus 로고
    • Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize and quantify the strain rates of the active human myocardium
    • Wedeen V. Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize and quantify the strain rates of the active human myocardium. Magn Reson Med 1992;27:52-67.
    • (1992) Magn Reson Med , vol.27 , pp. 52-67
    • Wedeen, V.1
  • 15
    • 0028584207 scopus 로고
    • Evaluation of myocardial motion tracking with cine-phase contrast magnetic resonance imaging
    • Pelc L, Sayre J, Yun K, Castro L, Herfkens RJ, Miller D, Pelc N. Evaluation of myocardial motion tracking with cine-phase contrast magnetic resonance imaging. Invest Radiol 1994;29:1038-1042.
    • (1994) Invest Radiol , vol.29 , pp. 1038-1042
    • Pelc, L.1    Sayre, J.2    Yun, K.3    Castro, L.4    Herfkens, R.J.5    Miller, D.6    Pelc, N.7
  • 18
    • 0032770117 scopus 로고    scopus 로고
    • Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial infarction
    • Arai A, Gaither C III, Epstein F, Balaban R, Wolff S. Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial infarction. Magn Reson Med 1999;42:98-109.
    • (1999) Magn Reson Med , vol.42 , pp. 98-109
    • Arai, A.1    Gaither C. III2    Epstein, F.3    Balaban, R.4    Wolff, S.5
  • 19
    • 0001643773 scopus 로고    scopus 로고
    • A double trigger unit for ECG and breath triggered mouse heart imaging
    • European Society for Magnetic Resonance in Medicine and Biology
    • Rommel E, Kuhstrebe J, Wiesmann F, Szimtenings M, Streif J, Haase A. A double trigger unit for ECG and breath triggered mouse heart imaging (abstract). In: Proc 17th Annual Meeting, European Society for Magnetic Resonance in Medicine and Biology, 2000. p 568.
    • (2000) Proc 17th Annual Meeting , pp. 568
    • Rommel, E.1    Kuhstrebe, J.2    Wiesmann, F.3    Szimtenings, M.4    Streif, J.5    Haase, A.6
  • 22
    • 0023217321 scopus 로고
    • Improving MR image quality in the presence of motion by using rephasing gradients
    • Haacke E, Lenz G. Improving MR image quality in the presence of motion by using rephasing gradients. Am J Roentgenol 1987;148:1251-1258.
    • (1987) Am J Roentgenol , vol.148 , pp. 1251-1258
    • Haacke, E.1    Lenz, G.2
  • 23
    • 0023081639 scopus 로고
    • MR flow imaging of velocity compensated/uncompensated difference images
    • Axel L, Morton D. MR flow imaging of velocity compensated/uncompensated difference images. J Comput Assist Tomogr 1987;11:31.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 31
    • Axel, L.1    Morton, D.2
  • 24
    • 0026876194 scopus 로고
    • Elimination of oblique flow artifacts in magnetic resonance imaging
    • Frank L, Crawley A, Buxton R. Elimination of oblique flow artifacts in magnetic resonance imaging. Magn Reson Med 1992;25:299.
    • (1992) Magn Reson Med , vol.25 , pp. 299
    • Frank, L.1    Crawley, A.2    Buxton, R.3
  • 25
  • 26
    • 0026344889 scopus 로고
    • On the nature and reduction of displacement artefacts in flow images
    • Nishimura D, Jackson J, Pauly J. On the nature and reduction of displacement artefacts in flow images. Magn Reson Med 1991;22:481-492.
    • (1991) Magn Reson Med , vol.22 , pp. 481-492
    • Nishimura, D.1    Jackson, J.2    Pauly, J.3
  • 27
    • 0028099916 scopus 로고
    • Pulse sequence design for MR velocity mapping of complex flow: Notes on necessity of low echo times
    • Stahlberg F, Thomson C, Soondergaard L, Henrikson O. Pulse sequence design for MR velocity mapping of complex flow: notes on necessity of low echo times. Magn Reson Imag 1994;12:1255-1262.
    • (1994) Magn Reson Imag , vol.12 , pp. 1255-1262
    • Stahlberg, F.1    Thomson, C.2    Soondergaard, L.3    Henrikson, O.4
  • 28
    • 0020340302 scopus 로고
    • A flow zeugmatographic interlace for NMR imaging in humans
    • Moran P. A flow zeugmatographic interlace for NMR imaging in humans. Magn Reson Imag 1984;1:197-203.
    • (1984) Magn Reson Imag , vol.1 , pp. 197-203
    • Moran, P.1
  • 29
    • 0033505307 scopus 로고    scopus 로고
    • Cardiac phase contrast gradient echo MRI: Measurement of myocardial wall motion in healthy volunteers and patients
    • Markl M, Schneider B, Hennig J, Peschl S, Winterer J, Krause T, Laubenberger J. Cardiac phase contrast gradient echo MRI: measurement of myocardial wall motion in healthy volunteers and patients. Int J Card Imag 1999;15:441-452.
    • (1999) Int J Card Imag , vol.15 , pp. 441-452
    • Markl, M.1    Schneider, B.2    Hennig, J.3    Peschl, S.4    Winterer, J.5    Krause, T.6    Laubenberger, J.7
  • 30
    • 0026011828 scopus 로고
    • Adaptive motion compensation in MRI: Accuracy of motion measurement
    • Felmlee J, Ehman R, Riederer S, Korin H. Adaptive motion compensation in MRI: accuracy of motion measurement. Magn Reson Med 1991;18:207-213.
    • (1991) Magn Reson Med , vol.18 , pp. 207-213
    • Felmlee, J.1    Ehman, R.2    Riederer, S.3    Korin, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.