메뉴 건너뛰기




Volumn 96, Issue 2, 2003, Pages 606-610

The brandt™ tube system attenuates the cuff deflationary phenomenon after anesthesia with nitrous oxide

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHETIC AGENT; NEUROMUSCULAR BLOCKING AGENT; NITROUS OXIDE; PROPOFOL; VECURONIUM; INHALATION ANESTHETIC AGENT;

EID: 0037303768     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000539-200302000-00055     Document Type: Article
Times cited : (7)

References (21)
  • 1
    • 0016303247 scopus 로고
    • Effects of nitrous oxide on volume and pressure of endotracheal tube cuffs
    • Stanley TH, Kawamura R, Graves C. Effects of nitrous oxide on volume and pressure of endotracheal tube cuffs. Anesthesiology 1974;41:256-62.
    • (1974) Anesthesiology , vol.41 , pp. 256-262
    • Stanley, T.H.1    Kawamura, R.2    Graves, C.3
  • 2
    • 0033864060 scopus 로고    scopus 로고
    • The effect on intracuff pressure of various nitrous oxide concentrations used for inflating an endotracheal tube cuff
    • Karasawa F, Ohshima T, Takamatsu I, et al. The effect on intracuff pressure of various nitrous oxide concentrations used for inflating an endotracheal tube cuff. Anesth Analg 2000;91: 708-13.
    • (2000) Anesth Analg , vol.91 , pp. 708-713
    • Karasawa, F.1    Ohshima, T.2    Takamatsu, I.3
  • 3
    • 0035174285 scopus 로고    scopus 로고
    • Deflationary phenomenon of the nitrous oxide-filled endotracheal tube cuff after cessation of nitrous oxide administration
    • Karasawa F, Mori T, Kawatani Y, et al. Deflationary phenomenon of the nitrous oxide-filled endotracheal tube cuff after cessation of nitrous oxide administration. Anesth Analg 2001;92: 145-8.
    • (2001) Anesth Analg , vol.92 , pp. 145-148
    • Karasawa, F.1    Mori, T.2    Kawatani, Y.3
  • 4
    • 0028799830 scopus 로고
    • A new endotracheal tube with a cuff impervious to nitrous oxide: Constancy of pressure and volume
    • Fujikawa M, Mizoguchi H, Kawamura J, et al. A new endotracheal tube with a cuff impervious to nitrous oxide: constancy of pressure and volume. Anesth Analg 1995;81:1084-6.
    • (1995) Anesth Analg , vol.81 , pp. 1084-1086
    • Fujikawa, M.1    Mizoguchi, H.2    Kawamura, J.3
  • 6
    • 0035172679 scopus 로고    scopus 로고
    • Profile Soft-Seal Cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide
    • Karasawa F, Mori T, Okuda T, Satoh T. Profile Soft-Seal Cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide. Anesth Analg 2001;92:140-4.
    • (2001) Anesth Analg , vol.92 , pp. 140-144
    • Karasawa, F.1    Mori, T.2    Okuda, T.3    Satoh, T.4
  • 7
    • 0018819716 scopus 로고
    • The tracheal tube cuff pressure stabilizer and its clinical evaluation
    • Kim JM. The tracheal tube cuff pressure stabilizer and its clinical evaluation. Anesth Analg 1980;59:291-6.
    • (1980) Anesth Analg , vol.59 , pp. 291-296
    • Kim, J.M.1
  • 8
    • 0019789452 scopus 로고
    • A new tracheostomy tube. III. Bronchofiberoptic examination of the trachea after prolonged intubation with the NL tracheostomy tube
    • Lomholt N, Borgeskov S, Kirkby B. A new tracheostomy tube. III. Bronchofiberoptic examination of the trachea after prolonged intubation with the NL tracheostomy tube. Acta Anaesthesiol Scand 1981;25:407-11.
    • (1981) Acta Anaesthesiol Scand , vol.25 , pp. 407-411
    • Lomholt, N.1    Borgeskov, S.2    Kirkby, B.3
  • 9
    • 0026766916 scopus 로고
    • Sore throat after endotracheal intubation
    • Mandoe H, Nikolajsen L, Lintrup U, et al. Sore throat after endotracheal intubation. Anesth Analg 1992;74:897-900.
    • (1992) Anesth Analg , vol.74 , pp. 897-900
    • Mandoe, H.1    Nikolajsen, L.2    Lintrup, U.3
  • 10
    • 0025138290 scopus 로고
    • A modified epidural syringe as an endotracheal tube cuff pressure-controlling device
    • Resnikoff E, Katz JA. A modified epidural syringe as an endotracheal tube cuff pressure-controlling device. Anesth Analg 1990;70:208-11.
    • (1990) Anesth Analg , vol.70 , pp. 208-211
    • Resnikoff, E.1    Katz, J.A.2
  • 11
    • 0027230406 scopus 로고
    • The Miller tracheal cuff pressure control valve
    • Payne KA, Miller DM. The Miller tracheal cuff pressure control valve. Anaesthesia 1993;48:324-7.
    • (1993) Anaesthesia , vol.48 , pp. 324-327
    • Payne, K.A.1    Miller, D.M.2
  • 12
    • 0020828050 scopus 로고
    • The rediffusion system: Limitation of nitrous oxide-induced increase of the pressure of endotracheal tube cuffs
    • Brandt L, Pokar H. The rediffusion system: limitation of nitrous oxide-induced increase of the pressure of endotracheal tube cuffs. Anaesthetist 1983;32:459-64.
    • (1983) Anaesthetist , vol.32 , pp. 459-464
    • Brandt, L.1    Pokar, H.2
  • 13
    • 0028217977 scopus 로고
    • Rediffusion of nitrous oxide prevents increases in endotracheal tube cuff pressure
    • Fill DM, Dosch MP, Bruni MR. Rediffusion of nitrous oxide prevents increases in endotracheal tube cuff pressure. AANA J 1994;62:77-81.
    • (1994) AANA J , vol.62 , pp. 77-81
    • Fill, D.M.1    Dosch, M.P.2    Bruni, M.R.3
  • 14
    • 0021260456 scopus 로고
    • Endotracheal cuff pressure and tracheal mucosal blood flow: Endoscopic study of effects of four large volume cuffs
    • Seegobin RD, Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J 1984;288:965-8.
    • (1984) Br Med J , vol.288 , pp. 965-968
    • Seegobin, R.D.1    Hasselt, G.L.2
  • 15
    • 0020315273 scopus 로고
    • Lubrication of tracheal tubes to prevent sore throat from intubation
    • Stock MC, Downs JB. Lubrication of tracheal tubes to prevent sore throat from intubation. Anesthesiology 1982;57:418-20.
    • (1982) Anesthesiology , vol.57 , pp. 418-420
    • Stock, M.C.1    Downs, J.B.2
  • 17
    • 0020533181 scopus 로고
    • The influence of endotracheal tube cuff design and cuff lubricant on postoperative sore throat
    • Loeser EA, Kaminsky A, Diaz A, et al. The influence of endotracheal tube cuff design and cuff lubricant on postoperative sore throat. Anesthesiology 1983;58:376-9.
    • (1983) Anesthesiology , vol.58 , pp. 376-379
    • Loeser, E.A.1    Kaminsky, A.2    Diaz, A.3
  • 18
    • 0023615016 scopus 로고
    • No increased incidence of postoperative sore throat after administration of suxamethonium in endotracheal anaesthesia
    • Jorgensen LN, Weber M, Pedersen A, Munster M. No increased incidence of postoperative sore throat after administration of suxamethonium in endotracheal anaesthesia. Acta Anaesthesiol Scand 1987;31:768-70.
    • (1987) Acta Anaesthesiol Scand , vol.31 , pp. 768-770
    • Jorgensen, L.N.1    Weber, M.2    Pedersen, A.3    Munster, M.4
  • 19
    • 0023552811 scopus 로고
    • Correlation of endotracheal tube size with sore throat and hoarseness following general anesthesia
    • Stout DM, Bishop MJ, Dwersteg JF, Cullen BF. Correlation of endotracheal tube size with sore throat and hoarseness following general anesthesia. Anesthesiology 1987;67:419-21.
    • (1987) Anesthesiology , vol.67 , pp. 419-421
    • Stout, D.M.1    Bishop, M.J.2    Dwersteg, J.F.3    Cullen, B.F.4
  • 20
    • 0025025047 scopus 로고
    • Postoperative sore throat: Effect of oropharyngeal airway in orotracheally intubated patients
    • Monroe M, Gravenstein N, Saga-Rumley S. Postoperative sore throat: effect of oropharyngeal airway in orotracheally intubated patients. Anesth Analg 1990;70:512-26.
    • (1990) Anesth Analg , vol.70 , pp. 512-526
    • Monroe, M.1    Gravenstein, N.2    Saga-Rumley, S.3
  • 21
    • 0027314865 scopus 로고
    • Beclomethasone prevents postoperative sore throat
    • Hakim ME. Beclomethasone prevents postoperative sore throat. Acta Anaesthesiol Scand 1993;37:250-2.
    • (1993) Acta Anaesthesiol Scand , vol.37 , pp. 250-252
    • Hakim, M.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.