메뉴 건너뛰기




Volumn 54, Issue 2, 2003, Pages 236-241

Reliability of mixed venous oxygen saturation as an indicator of the oxygen extraction ratio demonstrated by a large patient data set

Author keywords

Clinical monitoring; Critical care methods; Mixed venous satura tion; Oxygen consumption; Oxygen extraction ratio; Oxygen blood

Indexed keywords

ARTICLE; CALCULATION; CORRELATION ANALYSIS; CRITICAL ILLNESS; EXTRACTION; HEMOGLOBIN DETERMINATION; HUMAN; MEDICAL RECORD; OXYGEN BLOOD LEVEL; OXYGEN CONSUMPTION; OXYGEN SATURATION; OXYGEN TENSION; OXYGEN TISSUE LEVEL; PATIENT MONITORING; PREDICTION; PRIORITY JOURNAL; RELIABILITY; STATISTICAL ANALYSIS; TISSUE OXYGENATION;

EID: 0037300558     PISSN: 00225282     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.TA.0000047806.22943.05     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 0021701851 scopus 로고
    • Clinical experience with continuous monitoring of mixed venous oxygen saturation in respiratory failure
    • Fahey PJ, Harris K, Vanderwarf C. Clinical experience with continuous monitoring of mixed venous oxygen saturation in respiratory failure. Chest. 1984; 86: 748-752.
    • (1984) Chest , vol.86 , pp. 748-752
    • Fahey, P.J.1    Harris, K.2    Vanderwarf, C.3
  • 2
    • 0027348720 scopus 로고
    • Continuous measurement of mixed venous oxygen saturation (In German)
    • Hannemann L, Reinhart K. Continuous measurement of mixed venous oxygen saturation (in German). Acta Med Austriaca. 1993; 20: 107-111.
    • (1993) Acta Med Austriaca , vol.20 , pp. 107-111
    • Hannemann, L.1    Reinhart, K.2
  • 3
    • 0026846759 scopus 로고
    • The physiopathology of oxygen venous saturation (In Italian)
    • Tufano R, Gravino E, Pezza M. The physiopathology of oxygen venous saturation (in Italian). Minerva Anestesiol. 1992; 58 (4 suppl 1):5-13.
    • (1992) Minerva Anestesiol , vol.58 , Issue.4 , pp. 5-13
    • Tufano, R.1    Gravino, E.2    Pezza, M.3
  • 4
    • 0024949272 scopus 로고
    • Factors influencing mixed venous oxygen saturation in intensive care (In French)
    • Rouby JJ, Poete P, Bodin L, et al. Factors influencing mixed venous oxygen saturation in intensive care (in French). Ann Fr Anesth Reanim. 1989; 8: 703-707.
    • (1989) Ann Fr Anesth Reanim , vol.8 , pp. 703-707
    • Rouby, J.J.1    Poete, P.2    Bodin, L.3
  • 5
    • 4244033762 scopus 로고    scopus 로고
    • Theoretical analysis of the effect of inspired oxygen concentrations on mixed venous oxygen saturation determinations
    • Keech JC, Reed RL. Theoretical analysis of the effect of inspired oxygen concentrations on mixed venous oxygen saturation determinations. Crit Care Med. 2001; 29 (suppl 12): A111.
    • (2001) Crit Care Med , vol.29 , pp. A111
    • Keech, J.C.1    Reed, R.L.2
  • 6
    • 0013934131 scopus 로고
    • Digital computer subroutine for the conversion of oxygen tension into saturation
    • Kelman GR. Digital computer subroutine for the conversion of oxygen tension into saturation. J Appl Physiol. 1966; 21: 1375-1376.
    • (1966) J Appl Physiol , vol.21 , pp. 1375-1376
    • Kelman, G.R.1
  • 7
    • 0032434106 scopus 로고    scopus 로고
    • Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof
    • Jubran A, Mathru M, Dries D, Tobin MJ. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof. Am J Respir Crit Care Med. 1998; 158: 1763-1769.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 1763-1769
    • Jubran, A.1    Mathru, M.2    Dries, D.3    Tobin, M.J.4
  • 8
    • 0023412103 scopus 로고
    • Mixed venous hemoglobin saturation: Theory and application
    • Schweiss JF. Mixed venous hemoglobin saturation: theory and application. Int Anesthesiol Clin. 1987; 25: 113-136.
    • (1987) Int Anesthesiol Clin , vol.25 , pp. 113-136
    • Schweiss, J.F.1
  • 9
    • 0036591428 scopus 로고    scopus 로고
    • Effects of increasing FiO2 on venous saturation during cardiopulmonary bypass in the swine model
    • Nichols JD, Stammers AH, Kmiecik SA, et al. Effects of increasing FiO2 on venous saturation during cardiopulmonary bypass in the swine model. J Extra Corpor Technol. 2002; 34: 118-124.
    • (2002) J Extra Corpor Technol , vol.34 , pp. 118-124
    • Nichols, J.D.1    Stammers, A.H.2    Kmiecik, S.A.3
  • 10
    • 0028212453 scopus 로고
    • The relation between cardiac index and oxygen extraction in acutely ill patients
    • Silance PG, Simon C, Vincent JL. The relation between cardiac index and oxygen extraction in acutely ill patients. Chest. 1994; 105: 1190-1197.
    • (1994) Chest , vol.105 , pp. 1190-1197
    • Silance, P.G.1    Simon, C.2    Vincent, J.L.3
  • 11
    • 0026675105 scopus 로고
    • An uncommon cause of acute right ventricular failure and high mixed venous oxygen saturation
    • Peake SL, Pavia JA, Bihari DJ, Chambers JB. An uncommon cause of acute right ventricular failure and high mixed venous oxygen saturation. Intensive Care Med. 1992; 18: 368-370.
    • (1992) Intensive Care Med , vol.18 , pp. 368-370
    • Peake, S.L.1    Pavia, J.A.2    Bihari, D.J.3    Chambers, J.B.4
  • 13
    • 0031838159 scopus 로고    scopus 로고
    • A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure
    • Walsh TS, Hopton P, Lee A. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure. Crit Care Med. 1998; 26: 1200-1207.
    • (1998) Crit Care Med , vol.26 , pp. 1200-1207
    • Walsh, T.S.1    Hopton, P.2    Lee, A.3
  • 14
    • 0026750580 scopus 로고
    • Effects of cardiovascular drugs on oxygen consumption/oxygen delivery relationship in patients with congestive heart failure
    • Teboul JL, Annane D, Thuillez C, Depret J, Bellissant E, Richard C. Effects of cardiovascular drugs on oxygen consumption/oxygen delivery relationship in patients with congestive heart failure. Chest. 1992; 101: 1582-1587.
    • (1992) Chest , vol.101 , pp. 1582-1587
    • Teboul, J.L.1    Annane, D.2    Thuillez, C.3    Depret, J.4    Bellissant, E.5    Richard, C.6
  • 15
    • 0028218881 scopus 로고
    • Dissociation of mixed venous oxygen saturation and cardiac index during opioid induction
    • Colonna-Romano P, Horrow JC. Dissociation of mixed venous oxygen saturation and cardiac index during opioid induction. J Clin Anesth. 1994; 6: 95-98.
    • (1994) J Clin Anesth , vol.6 , pp. 95-98
    • Colonna-Romano, P.1    Horrow, J.C.2
  • 16
    • 0035075570 scopus 로고    scopus 로고
    • Measured fraction of carboxyhaemoglobin depends on oxygen saturation of haemoglobin
    • Hutler M, Beneke R, Littschwager A, Boning D. Measured fraction of carboxyhaemoglobin depends on oxygen saturation of haemoglobin. Scand J Clin Lab Invest. 2001; 61: 83-87.
    • (2001) Scand J Clin Lab Invest , vol.61 , pp. 83-87
    • Hutler, M.1    Beneke, R.2    Littschwager, A.3    Boning, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.