메뉴 건너뛰기




Volumn 33, Issue 1, 2003, Pages 20-25

The XS/XXS and XSL compressions nail in the management of olecranon and proximal ulna fractures;Der XS/XXS- und XSL-zuggurtungskompressionsnagel in der versorgung von olekranon- und proximalen ulnafrakturen

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE NAIL; BONE SCREW; DEVICE; FRACTURE FIXATION; HUMAN; IMPLANT; MAJOR CLINICAL STUDY; OLECRANON FRACTURE; OSTEOSYNTHESIS; OSTEOTOMY; SOFT TISSUE; SURGICAL TECHNIQUE; TREATMENT OUTCOME; ULNA FRACTURE;

EID: 0037299280     PISSN: 00446173     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-37886     Document Type: Article
Times cited : (3)

References (7)
  • 1
    • 0012519723 scopus 로고    scopus 로고
    • Experimentelle untersuchungen zur wirksamkeit des zuggurtungskompressionsnagels (XS-Nagel) am beispiel der patellafraktur
    • Friedl W, Clausen J. Experimentelle Untersuchungen zur Wirksamkeit des Zuggurtungskompressionsnagels (XS-Nagel) am Beispiel der Patellafraktur. Osteosynthese International 2000; 8: 252-260
    • (2000) Osteosynthese International , vol.8 , pp. 252-260
    • Friedl, W.1    Clausen, J.2
  • 2
    • 0347871241 scopus 로고    scopus 로고
    • Probleme der patella-zuggurtungsosteosynthese und konsequenzen für die entwicklung eines neuenmplantates. Der XS-Nagel
    • Gehr J, Friedl W. Probleme der Patella-Zuggurtungsosteosynthese und Konsequenzen für die Entwicklung eines neuenmplantates. Der XS-Nagel. Chirurg 2001; 72: 1309-1317
    • (2001) Chirurg , vol.72 , pp. 1309-1317
    • Gehr, J.1    Friedl, W.2
  • 3
    • 0034237449 scopus 로고    scopus 로고
    • K-wire positioning - A comparison of two techniques
    • Mullet JH. K-wire positioning - A comparison of two techniques. Injury 2000; 31: 427-431
    • (2000) Injury , vol.31 , pp. 427-431
    • Mullet, J.H.1
  • 4
    • 0023514940 scopus 로고
    • Displaced olecranon fractures in adults: Clinical evaluation
    • Murphy DR, Greene WB, Dameron TB. Displaced olecranon fractures in adults: clinical evaluation. Clin Orthop 1987; 224: 215-223
    • (1987) Clin Orthop , vol.224 , pp. 215-223
    • Murphy, D.R.1    Greene, W.B.2    Dameron, T.B.3
  • 5
    • 0031267131 scopus 로고    scopus 로고
    • Biomechanical comparison of fixing methods in transverse olecranon fractures: A cadaveric study
    • Prayson MJ. Biomechanical comparison of fixing methods in transverse olecranon fractures: a cadaveric study. J Orthop Trauma 1997; 11: 565-572
    • (1997) J Orthop Trauma , vol.11 , pp. 565-572
    • Prayson, M.J.1
  • 6
    • 0033831194 scopus 로고    scopus 로고
    • Complications and re-operation rate after tension-band wiring in olecranon fractures
    • Romero JM, Miram A, Jensen CL. Complications and re-operation rate after tension-band wiring in olecranon fractures. J Orthop Sci 2000; 5: 318-320
    • (2000) J Orthop Sci , vol.5 , pp. 318-320
    • Romero, J.M.1    Miram, A.2    Jensen, C.L.3
  • 7
    • 0030198892 scopus 로고    scopus 로고
    • Contoured LCDC plating of the proximal ulna
    • Simpson NS, Goodmann LA, Jupiter JB. Contoured LCDC plating of the proximal ulna. Injury 1996; 27: 411-417
    • (1996) Injury , vol.27 , pp. 411-417
    • Simpson, N.S.1    Goodmann, L.A.2    Jupiter, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.