메뉴 건너뛰기




Volumn 29, Issue 2, 2003, Pages 277-284

Nonlinear coded excitation method for ultrasound contrast imaging

Author keywords

Bubbles; Chirp; Coded excitation; Contrast agents; Ultrasound

Indexed keywords

COMPUTER SIMULATION; MEDICAL IMAGING; NATURAL FREQUENCIES; SIGNAL TO NOISE RATIO;

EID: 0037298617     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(02)00712-3     Document Type: Article
Times cited : (68)

References (15)
  • 1
    • 0001794708 scopus 로고    scopus 로고
    • Experimental observations of the sensitivity and frequency response of the power modulation technique for contrast imaging
    • Ten Cate FJ, de Jong N, Cosgrove DO, eds. Rotterdam
    • Brock-Fisher G, Poland M, Rafter P, Mooney M. Experimental observations of the sensitivity and frequency response of the power modulation technique for contrast imaging. In: Ten Cate FJ, de Jong N, Cosgrove DO, eds. Fifth Heart Centre European Symposium on Ultrasound Contrast Imaging. Rotterdam: 2000:1-77.
    • (2000) Fifth Heart Centre European Symposium on Ultrasound Contrast Imaging , pp. 1-77
    • Brock-Fisher, G.1    Poland, M.2    Rafter, P.3    Mooney, M.4
  • 2
    • 0001281584 scopus 로고
    • Harmonic imaging: A new imaging and Doppler method for contrast enhanced ultrasound
    • Burns P.N., Powers J.E., Fritzsch T. Harmonic imaging A new imaging and Doppler method for contrast enhanced ultrasound . Radiology. 185:1992;142.
    • (1992) Radiology , vol.185 , pp. 142
    • Burns, P.N.1    Powers, J.E.2    Fritzsch, T.3
  • 3
    • 0028549958 scopus 로고
    • Higher harmonics of vibrating gas filled microspheres. Part one: Simulations
    • de Jong N., Cornet R., Lancée C.T. Higher harmonics of vibrating gas filled microspheres. Part one Simulations . Ultrasonics. 32:1994;447-453.
    • (1994) Ultrasonics , vol.32 , pp. 447-453
    • De Jong, N.1    Cornet, R.2    Lancée, C.T.3
  • 4
    • 0033727931 scopus 로고    scopus 로고
    • Influence of bubble size distribution on the echogenicity of ultrasound contrast agents: A study of SonoVue™
    • Gorce J.-M., Arditi M., Schneider M. Influence of bubble size distribution on the echogenicity of ultrasound contrast agents A study of SonoVue™ Invest Radiol. 35:2000;661-671.
    • (2000) Invest Radiol , vol.35 , pp. 661-671
    • Gorce, J.-M.1    Arditi, M.2    Schneider, M.3
  • 5
    • 0033096935 scopus 로고    scopus 로고
    • Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents
    • Hope Simpson D., Chin C.T., Burns P.N. Pulse inversion Doppler A new method for detecting nonlinear echoes from microbubble contrast agents . IEEE Trans Ultrason Ferroelec Freq Control. 46:1999;372-382.
    • (1999) IEEE Trans Ultrason Ferroelec Freq Control , vol.46 , pp. 372-382
    • Hope Simpson, D.1    Chin, C.T.2    Burns, P.N.3
  • 6
    • 0028843409 scopus 로고
    • Time-domain modelling of pulsed finite-amplitude sound beams
    • Lee Y., Hamilton M.F. Time-domain modelling of pulsed finite-amplitude sound beams. J Acoust Soc Am. 97:1995;906-917.
    • (1995) J Acoust Soc Am , vol.97 , pp. 906-917
    • Lee, Y.1    Hamilton, M.F.2
  • 7
    • 0017347470 scopus 로고
    • Counting bubbles acoustically: A review
    • Medwin H. Counting bubbles acoustically A review . Ultrasonics. 15:1977;70-73.
    • (1977) Ultrasonics , vol.15 , pp. 70-73
    • Medwin, H.1
  • 9
    • 0026866582 scopus 로고
    • Coded excitation system for improving the penetration of real-time phased-array imaging systems
    • O'Donnell M. Coded excitation system for improving the penetration of real-time phased-array imaging systems. IEEE Trans Ultrason Ferroelec Freq Control. 39:1992;341-351.
    • (1992) IEEE Trans Ultrason Ferroelec Freq Control , vol.39 , pp. 341-351
    • O'Donnell, M.1
  • 11
    • 0028397372 scopus 로고
    • Investigation of a pulse compression technique for medical ultrasound: A simulation study
    • Rao N.A.H.K. Investigation of a pulse compression technique for medical ultrasound A simulation study . Med Biol Eng Comput. 32:1994;181-188.
    • (1994) Med Biol Eng Comput , vol.32 , pp. 181-188
    • Rao, N.A.H.K.1
  • 12
    • 0027496845 scopus 로고
    • Second harmonic ultrasonic blood perfusion measurement
    • Schrope B.A., Newhouse V.L. Second harmonic ultrasonic blood perfusion measurement. Ultrasound Med Biol. 19:1993;567-579.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 567-579
    • Schrope, B.A.1    Newhouse, V.L.2
  • 14
    • 0029464453 scopus 로고
    • Chirped excitation for < -100 dB time sidelobe echo sounding
    • Takeuchi Y. Chirped excitation for < -100 dB time sidelobe echo sounding. IEEE Ultrason Sympos Proc. 2:1995;1309-1314.
    • (1995) IEEE Ultrason Sympos Proc , vol.2 , pp. 1309-1314
    • Takeuchi, Y.1
  • 15
    • 0030371008 scopus 로고    scopus 로고
    • Coded excitation for harmonics imaging
    • Takeuchi Y. Coded excitation for harmonics imaging. IEEE Ultrason Symp Proc. 2:1996;1433-1435.
    • (1996) IEEE Ultrason Symp Proc , vol.2 , pp. 1433-1435
    • Takeuchi, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.