메뉴 건너뛰기




Volumn 56, Issue 2, 2003, Pages 145-151

Coronary angiography with 4 F catheters by the radial: Minimally invasive catheterization;Angiografía coronaria con catéteres de 4 F por la vía radial: El «cateterismo mínimamente invasio»

Author keywords

Angiography; Cardiac catheterization; Catheters

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY DIAMETER; ARTICLE; CLINICAL STUDY; CONTROLLED STUDY; CORONARY ARTERY DILATATION; CORONARY ARTERY DISEASE; CORRELATION ANALYSIS; DIAGNOSTIC PROCEDURE; EXPERIENCE; FEMALE; FEMORAL VEIN; FOLLOW UP; HEART CATHETER; HEART CATHETERIZATION; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; QUANTITATIVE ANALYSIS; RADIAL ARTERY; RATING SCALE; RIGHT CORONARY ARTERY; VASCULAR ACCESS; VASCULAR DISEASE;

EID: 0037294425     PISSN: 03008932     EISSN: None     Source Type: Journal    
DOI: 10.1157/13043220     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0035927970 scopus 로고    scopus 로고
    • Comparison of early invasive and conservative strategies in patients with unstable coronary syndromes treated with the glycoprotein IIb/IIIa inhibitor tirofiban
    • Cannon CP, Weintraub WS, Demopoulos LA, Vicari R, Frey MJ, Lakkis N, et al. Comparison of early invasive and conservative strategies in patients with unstable coronary syndromes treated with the glycoprotein IIb/IIIa inhibitor tirofiban. N Engl J Med 2001;344:1879-87.
    • (2001) N. Engl. J. Med. , vol.344 , pp. 1879-1887
    • Cannon, C.P.1    Weintraub, W.S.2    Demopoulos, L.A.3    Vicari, R.4    Frey, M.J.5    Lakkis, N.6
  • 2
    • 0030998942 scopus 로고    scopus 로고
    • A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: The Access study
    • Kiemeneij F, Laarman GJ, Odekerken D, Slagboom T, Van der Wicken R. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the Access study. J Am Coll Cardiol 1997;29:1269-75.
    • (1997) J. Am. Coll. Cardiol. , vol.29 , pp. 1269-1275
    • Kiemeneij, F.1    Laarman, G.J.2    Odekerken, D.3    Slagboom, T.4    Van der Wicken, R.5
  • 4
    • 0032822262 scopus 로고    scopus 로고
    • Effect of transradial access on quality of life and cost of cardiac catheterization: A randomized comparison
    • Cooper CJ, El-Schiekh RA, Cohen DJ, Blaesing L, Burket MW, Basu A, et al. Effect of transradial access on quality of life and cost of cardiac catheterization: a randomized comparison. Am Heart J 1999;138:430-6.
    • (1999) Am. Heart J. , vol.138 , pp. 430-436
    • Cooper, C.J.1    El-Schiekh, R.A.2    Cohen, D.J.3    Blaesing, L.4    Burket, M.W.5    Basu, A.6
  • 6
    • 0023179491 scopus 로고
    • Comparison of the performance of superflow (5 F) and conventional 8 F catheter for cardiac catheterization by the femoral route
    • Molajo AO, Ward C, Bray CL, Dobson D. Comparison of the performance of superflow (5 F) and conventional 8 F catheter for cardiac catheterization by the femoral route. Cathet Cardiovasc Diagn 1987;13:275-6.
    • (1987) Cathet. Cardiovasc. Diagn. , vol.13 , pp. 275-276
    • Molajo, A.O.1    Ward, C.2    Bray, C.L.3    Dobson, D.4
  • 7
    • 0025322084 scopus 로고
    • Comparison of 5 F and 7/8 F catheters for left ventricular and coronary angiography
    • Hui WK, Klinke WP, Kubac G, Talibi T. Comparison of 5 F and 7/8 F catheters for left ventricular and coronary angiography. Cathet Cardiovasc Diagn 1990;19:84-6.
    • (1990) Cathet. Cardiovasc. Diagn. , vol.19 , pp. 84-86
    • Hui, W.K.1    Klinke, W.P.2    Kubac, G.3    Talibi, T.4
  • 9
    • 20244384109 scopus 로고
    • A prospective randomized study of 4.1 French catheters utilizing the percutaneous right brachial approach for the diagnosis of coronary artery disease
    • Talley JD, Smith SM, Walton-Shirley M, Hattel L, Szabo T, Godlewski K, et al. A prospective randomized study of 4.1 French catheters utilizing the percutaneous right brachial approach for the diagnosis of coronary artery disease. Cathet Cardiovasc Diagn 1992;26:55-60.
    • (1992) Cathet. Cardiovasc. Diagn. , vol.26 , pp. 55-60
    • Talley, J.D.1    Smith, S.M.2    Walton-Shirley, M.3    Hattel, L.4    Szabo, T.5    Godlewski, K.6
  • 10
    • 0032929256 scopus 로고    scopus 로고
    • Randomized evaluation of four versus five French catheters for transfemoral coronary angiography
    • Metz D, Chapoutot L, Brasselet C, Jolly D. Randomized evaluation of four versus five French catheters for transfemoral coronary angiography. Clin Cardiol 1999;22:29-32.
    • (1999) Clin. Cardiol. , vol.22 , pp. 29-32
    • Metz, D.1    Chapoutot, L.2    Brasselet, C.3    Jolly, D.4
  • 11
    • 0035127412 scopus 로고    scopus 로고
    • Coronary angiography using 4 F catheters with Acisted Power injection: A randomized comparison to 6 F, manual technique and early ambulation
    • Khoukaz S, Kern MJ, Bitar SR, Azrak E, Eisenhauer M, Wolford T, et al. Coronary angiography using 4 F catheters with Acisted Power injection: a randomized comparison to 6 F, manual technique and early ambulation. Cathet Cardiovasc Intervent 2001;52:393-8.
    • (2001) Cathet. Cardiovasc. Intervent. , vol.52 , pp. 393-398
    • Khoukaz, S.1    Kern, M.J.2    Bitar, S.R.3    Azrak, E.4    Eisenhauer, M.5    Wolford, T.6
  • 12
    • 0034964765 scopus 로고    scopus 로고
    • Randomized comparison of coronary angiography using 4 F catheters: 4 F manual versus «Acisted» power injection technique
    • Chahoud G, Khoukaz S, El-Shafei A, Azrak E, Bitar S, Kern MJ. Randomized comparison of coronary angiography using 4 F catheters: 4 F manual versus «Acisted» power injection technique. Cathet Cardiovasc Intervent 2001;53:221-4.
    • (2001) Cathet. Cardiovasc. Intervent. , vol.53 , pp. 221-224
    • Chahoud, G.1    Khoukaz, S.2    El-Shafei, A.3    Azrak, E.4    Bitar, S.5    Kern, M.J.6
  • 13
    • 0034760215 scopus 로고    scopus 로고
    • Multicentre, prospective, randomized trial of 4 vs 6 French catheters in 410 patients undergoing coronary angiography
    • Todd DM, Hubner PJ, Hudson N, Sarma J, McCance AJ, Caplin J. Multicentre, prospective, randomized trial of 4 vs 6 French catheters in 410 patients undergoing coronary angiography. Cathet Cardiovasc Intervent 2001;54:269-75.
    • (2001) Cathet. Cardiovasc. Intervent. , vol.54 , pp. 269-275
    • Todd, D.M.1    Hubner, P.J.2    Hudson, N.3    Sarma, J.4    McCance, A.J.5    Caplin, J.6
  • 14
    • 0033556298 scopus 로고    scopus 로고
    • Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach
    • Nagai S, Abe S, Sato T, Hozawa K, Yuki K, Hanashima K, et al. Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach. Am J Cardiol 1999;83:180-6.
    • (1999) Am. J. Cardiol. , vol.83 , pp. 180-186
    • Nagai, S.1    Abe, S.2    Sato, T.3    Hozawa, K.4    Yuki, K.5    Hanashima, K.6
  • 15
    • 0029908297 scopus 로고    scopus 로고
    • Variations in measured vessel diameters using coronary measurement system
    • Robert N, Yaffe MJ, Langer A. Variations in measured vessel diameters using coronary measurement system. Cathet Cardiovasc Diagn 1996;39:131-6.
    • (1996) Cathet. Cardiovasc. Diagn. , vol.39 , pp. 131-136
    • Robert, N.1    Yaffe, M.J.2    Langer, A.3
  • 16
    • 0029845195 scopus 로고    scopus 로고
    • Reproducibility of quantitative coronary analysis. Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories
    • Sirnes PA, Myreng Y, Molstad P, Golf S. Reproducibility of quantitative coronary analysis. Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories. Int J Card Imaging 1996;12:197-203.
    • (1996) Int. J. Card. Imaging , vol.12 , pp. 197-203
    • Sirnes, P.A.1    Myreng, Y.2    Molstad, P.3    Golf, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.