메뉴 건너뛰기




Volumn 175, Issue 2, 2003, Pages 282-286

Vascular capsule for telemetric monitoring of blood pressure

Author keywords

Microelectromechanical system; Non invasive blood pressure monitoring; Pressure sensor; Transponder technology

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BLOOD PRESSURE MONITORING; BLOOD VESSEL CAPACITANCE; CONTROLLED STUDY; DATA ANALYSIS; ENERGY TRANSFER; FEEDBACK SYSTEM; IMPLANTATION; MEASUREMENT; NONHUMAN; PRESSURE SENSE; PRIORITY JOURNAL; PULSE RATE; SENSOR; SIGNAL PROCESSING; TELEMETRY;

EID: 0037292714     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-37232     Document Type: Article
Times cited : (8)

References (7)
  • 2
    • 0030382296 scopus 로고    scopus 로고
    • Compatible CMOS microsystems for automotive and for medical applications
    • Kersjes R, Mokwa W. Compatible CMOS microsystems for automotive and for medical applications. SPIE 1996; 2882: 37-48
    • (1996) SPIE , vol.2882 , pp. 37-48
    • Kersjes, R.1    Mokwa, W.2
  • 3
    • 0028428486 scopus 로고
    • Surface micromachined pressure sensors with integrated CMOS read-out electronics
    • Dudaicevs H, Kandler M, Manoli W, Mokwa W, Spiegel E. Surface micromachined pressure sensors with integrated CMOS read-out electronics. Sensors and Actuators 1994; A43: 157-163
    • (1994) Sensors and Actuators , vol.A43 , pp. 157-163
    • Dudaicevs, H.1    Kandler, M.2    Manoli, W.3    Mokwa, W.4    Spiegel, E.5
  • 4
    • 0012265974 scopus 로고    scopus 로고
    • Intravasculary Implantable Device. German Utility Model 29909923.7. International patent PCT WO 00/74557 A1, PCT/ DE00/01818
    • Schmitz-Rode T, Schnakenberg U, Mokwa W, Günther RW, Krüger C. Intravasculary Implantable Device. German Utility Model 29909923.7. International patent PCT WO 00/74557 A1, PCT/ DE00/01818.
    • Schmitz-Rode, T.1    Schnakenberg, U.2    Mokwa, W.3    Günther, R.W.4    Krüger, C.5
  • 6
    • 0034159075 scopus 로고    scopus 로고
    • Hemocompatibility of tubular polymers investigated with a modified Chandler Loop
    • Mottaghy K, Oedekoven B, Andersson C, Henseler A. Hemocompatibility of tubular polymers investigated with a modified Chandler Loop. ASAIO J 2000; 6: 232
    • (2000) ASAIO J , vol.6 , pp. 232
    • Mottaghy, K.1    Oedekoven, B.2    Andersson, C.3    Henseler, A.4
  • 7
    • 0032245675 scopus 로고    scopus 로고
    • Micromechanical pressure sensors for medical evaluation of blood vessels and bypasses after surgical intervention
    • Zacheja J, Wenzel D, Bach T, Clasbrummel B. Micromechanical pressure sensors for medical evaluation of blood vessels and bypasses after surgical intervention. Biomed Techn 1998; 43 (Suppl): 182 - 183
    • (1998) Biomed Techn , vol.43 , Issue.SUPPL. , pp. 182-183
    • Zacheja, J.1    Wenzel, D.2    Bach, T.3    Clasbrummel, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.