메뉴 건너뛰기




Volumn 28, Issue 2, 2003, Pages 141-155

Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; ALGORITHMS; ELECTRIC INVERTERS;

EID: 0037292229     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-5442(02)00113-5     Document Type: Article
Times cited : (102)

References (16)
  • 2
    • 34247612380 scopus 로고    scopus 로고
    • Optimal control of electronic expansion valves in modern low charge evaporator systems requires fast reacting expansion valves and new controller design
    • IIR/IIF, Sydney
    • Schmidt F. Optimal control of electronic expansion valves in modern low charge evaporator systems requires fast reacting expansion valves and new controller design. In: The 20th International Congress of Refrigeration, IIR/IIF, Sydney, 1999.
    • (1999) The 20th International Congress of Refrigeration
    • Schmidt, F.1
  • 3
    • 85019531748 scopus 로고    scopus 로고
    • Dynamic simulation of superheat at the evaporator outlet of the air conditioner with inverter
    • IIR/IIF, Sydney
    • Xia J, Zhou X, Jin X, Zhou Z. Dynamic simulation of superheat at the evaporator outlet of the air conditioner with inverter. In: The 20th International Congress of Refrigeration, IIR/IIF, Sydney, 1999
    • (1999) The 20th International Congress of Refrigeration
    • Xia, J.1    Zhou, X.2    Jin, X.3    Zhou, Z.4
  • 5
    • 0347579567 scopus 로고
    • Dynamic response and electrical control for the air conditioner
    • Matsuoka F, Nagatmo H. Dynamic response and electrical control for the air conditioner. JAR Trans 1988;5(1):43-54.
    • (1988) JAR Trans , vol.5 , Issue.1 , pp. 43-54
    • Matsuoka, F.1    Nagatmo, H.2
  • 6
    • 0000452641 scopus 로고
    • Evaporator superheat control by an electrically driven expansion valve
    • Yasuda H, Ishibane K, Nakayama S. Evaporator superheat control by an electrically driven expansion valve. JAR Trans 1992;9(2):147-56.
    • (1992) JAR Trans , vol.9 , Issue.2 , pp. 147-156
    • Yasuda, H.1    Ishibane, K.2    Nakayama, S.3
  • 7
    • 0012124946 scopus 로고
    • Multi air conditioner with two indoor units
    • Fujita Y, Kubo T, Suma S. Multi air conditioner with two indoor units. Refrigeration 1992;67(772):171-6.
    • (1992) Refrigeration , vol.67 , Issue.772 , pp. 171-176
    • Fujita, Y.1    Kubo, T.2    Suma, S.3