메뉴 건너뛰기




Volumn 16, Issue 1, 2003, Pages 29-35

Adiabatic RARE imaging

Author keywords

Adiabatic RF pulses; High magnetic field; RARE; Rat brain; Surface coil; Ultra fast MRI

Indexed keywords

DATA ACQUISITION; IMAGE QUALITY; LASER PULSES;

EID: 0037291628     PISSN: 09523480     EISSN: None     Source Type: Journal    
DOI: 10.1002/nbm.811     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J. Phys. C: Solid State Phys. 1977; 10: L55-L58.
    • (1977) J. Phys. C: Solid State Phys. , vol.10
    • Mansfield, P.1
  • 2
    • 0034056817 scopus 로고    scopus 로고
    • The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: A comparison of snapshot imaging techniques
    • Grieve SM, Blamire AM, Styles P. The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: a comparison of snapshot imaging techniques. Magn. Reson. Med. 2000; 43: 747-755.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 747-755
    • Grieve, S.M.1    Blamire, A.M.2    Styles, P.3
  • 3
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • Hennig J, Nauerth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn. Reson. Med. 1986; 3: 823-833.
    • (1986) Magn. Reson. Med. , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 4
    • 44949273876 scopus 로고
    • Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets
    • Garwood M, Ke Y. Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets. J. Magn. Reson. 1991; 94: 511-525.
    • (1991) J. Magn. Reson. , vol.94 , pp. 511-525
    • Garwood, M.1    Ke, Y.2
  • 5
    • 0003418720 scopus 로고    scopus 로고
    • In vivo NMR spectroscopy. Principles and techniques
    • Wiley: Chichester
    • de Graaf RA. In vivo NMR spectroscopy. Principles and techniques. Wiley: Chichester, 1998.
    • (1998)
    • de Graaf, R.A.1
  • 7
    • 48549111126 scopus 로고
    • Highly selective π/2 and π pulse generation
    • Silver MS, Joseph RI, Hoult DI. Highly selective π/2 and π pulse generation. J. Magn. Reson. 1984; 59: 347-351.
    • (1984) J. Magn. Reson. , vol.59 , pp. 347-351
    • Silver, M.S.1    Joseph, R.I.2    Hoult, D.I.3
  • 8
    • 0032110618 scopus 로고    scopus 로고
    • An adiabatic multiple spin-echo pulse sequence: Removal of systematic errors due to pulse imperfections and off-resonance effects
    • Zweckstetter M, Holak TA. An adiabatic multiple spin-echo pulse sequence: removal of systematic errors due to pulse imperfections and off-resonance effects. J. Magn. Reson. 1998; 133: 134-147.
    • (1998) J. Magn. Reson. , vol.133 , pp. 134-147
    • Zweckstetter, M.1    Holak, T.A.2
  • 9
    • 0023608696 scopus 로고
    • Fast three-dimensional imaging of cerebrospinal fluid
    • Hennig J, Friedburg H, Ott D. Fast three-dimensional imaging of cerebrospinal fluid. Magn. Reson. Med. 1987; 5: 380-383.
    • (1987) Magn. Reson. Med. , vol.5 , pp. 380-383
    • Hennig, J.1    Friedburg, H.2    Ott, D.3
  • 10
    • 0031981062 scopus 로고    scopus 로고
    • BASE imaging: A new spin labeling technique for measuring absolute perfusion changes
    • Schwarzbauer C, Heinke W. BASE imaging: a new spin labeling technique for measuring absolute perfusion changes. Magn. Reson. Med. 1998; 39: 717-722.
    • (1998) Magn. Reson. Med. , vol.39 , pp. 717-722
    • Schwarzbauer, C.1    Heinke, W.2
  • 12
    • 0023164952 scopus 로고
    • Errors in T2 estimation using multislice multiple-echo imaging
    • Crawley AP, Henkelman RM. Errors in T2 estimation using multislice multiple-echo imaging. Magn. Reson. Med. 1987; 4: 34-47.
    • (1987) Magn. Reson. Med. , vol.4 , pp. 34-47
    • Crawley, A.P.1    Henkelman, R.M.2
  • 13
    • 0030986479 scopus 로고    scopus 로고
    • Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans
    • Alsop DC. Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans. Magn. Reson. Med. 1997; 38: 527-533.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 527-533
    • Alsop, D.C.1
  • 14
    • 0029665944 scopus 로고    scopus 로고
    • Single-shot, B1-insensitive slice selection with a gradient-modulated adiabatic pulse, BISS-8
    • de Graaf RA, Nicolay K, Garwood M. Single-shot, B1-insensitive slice selection with a gradient-modulated adiabatic pulse, BISS-8. Magn. Reson. Med. 1996; 35: 652-657.
    • (1996) Magn. Reson. Med. , vol.35 , pp. 652-657
    • de Graaf, R.A.1    Nicolay, K.2    Garwood, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.