-
1
-
-
0003160373
-
Whole-body PET scanner using curve-plate NaI(Tl) detectors
-
J. S. Karp, G. Muehllehner, M. J. Geagan, and R. Freifelder, "Whole-body PET scanner using curve-plate NaI(Tl) detectors," J. Nucl. Med., vol. 39, p. 50P, 1998.
-
(1998)
J. Nucl. Med.
, vol.39
-
-
Karp, J.S.1
Muehllehner, G.2
Geagan, M.J.3
Freifelder, R.4
-
2
-
-
0001709720
-
Imaging properties of a half-inch sodium iodide gamma camera
-
June
-
T. G. Turkington, C. M. Laymon, and R. E. Coleman, "Imaging properties of a half-inch sodium iodide gamma camera," IEEE Trans. Nucl. Sci., vol. 44, pp. 1262-1265, June 1997.
-
(1997)
IEEE Trans. Nucl. Sci.
, vol.44
, pp. 1262-1265
-
-
Turkington, T.G.1
Laymon, C.M.2
Coleman, R.E.3
-
3
-
-
0003155529
-
Performance of a LSO/NaI(Tl) phoswich detector for a combined PET/SPECT imaging system
-
M. Schmand et al., "Performance of a LSO/NaI(Tl) phoswich detector for a combined PET/SPECT imaging system," J. Nucl. Med., vol. 41, no. 5, p. 9P, 1998.
-
(1998)
J. Nucl. Med.
, vol.41
, Issue.5
-
-
Schmand, M.1
-
4
-
-
0001307056
-
Initial characterization of a new hybrid tomograph: LSO/NaI PET/SPECT
-
A. van Lingen et al., "Initial characterization of a new hybrid tomograph: LSO/NaI PET/SPECT," J. Nucl. Med., vol. 41, no. 5, p. 20P, 2000.
-
(2000)
J. Nucl. Med.
, vol.41
, Issue.5
-
-
Van Lingen, A.1
-
5
-
-
0029358360
-
An analog decoding BGO block detector using circular photomultipliers
-
Aug.
-
W. H. Wong, J. Uribe, K. Hicks, and G. Hu, "An analog decoding BGO block detector using circular photomultipliers," IEEE Trans. Nucl. Sci., vol. 42, pp. 1095-1101, Aug. 1995.
-
(1995)
IEEE Trans. Nucl. Sci.
, vol.42
, pp. 1095-1101
-
-
Wong, W.H.1
Uribe, J.2
Hicks, K.3
Hu, G.4
-
6
-
-
0035725626
-
Slotted surface treatment of position-sensitive NaI(Tl) detectors to improve detector performance
-
Dec.
-
S. Surti, J. S. Karp, and R. Freifelder, "Slotted surface treatment of position-sensitive NaI(Tl) detectors to improve detector performance," IEEE Trans. Nucl. Sci., vol. 48, pp. 2418-2423, Dec. 2001.
-
(2001)
IEEE Trans. Nucl. Sci.
, vol.48
, pp. 2418-2423
-
-
Surti, S.1
Karp, J.S.2
Freifelder, R.3
-
7
-
-
0034204794
-
Optimizing the performance of a PET detector using discrete GSO crystals on a continuous lightguide
-
June
-
S. Surti, J. S. Karp, R. Freifelder, and F. Liu, "Optimizing the performance of a PET detector using discrete GSO crystals on a continuous lightguide," IEEE Trans. Nucl. Sci., vol. 47, pp. 1030-1036, June 2000.
-
(2000)
IEEE Trans. Nucl. Sci.
, vol.47
, pp. 1030-1036
-
-
Surti, S.1
Karp, J.S.2
Freifelder, R.3
Liu, F.4
-
8
-
-
0001181001
-
Event localization in a continuous scintillation detector using digital processing
-
Feb.
-
J. S. Karp, G. Muehllehner, D. Beerbohm, and D. Mankoff, "Event localization in a continuous scintillation detector using digital processing," IEEE Trans. Nucl. Sci., vol. NS-33, pp. 550-555, Feb. 1986.
-
(1986)
IEEE Trans. Nucl. Sci.
, vol.NS-33
, pp. 550-555
-
-
Karp, J.S.1
Muehllehner, G.2
Beerbohm, D.3
Mankoff, D.4
-
9
-
-
0032761238
-
Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
-
L.-E. Adam, J. S. Karp, and G. Brix, "Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations," Phys. Med. Biol., vol. 44, pp. 2879-2895, 1999.
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2879-2895
-
-
Adam, L.-E.1
Karp, J.S.2
Brix, G.3
-
10
-
-
0030482095
-
Monte Carlobased analysis of PET scatter components
-
L.-E. Adam, M. E. Bellemann, G. Brix, and W. J. Lorenz, "Monte Carlobased analysis of PET scatter components," J. Nucl. Med., vol. 37, pp. 2024-2029, 1996.
-
(1996)
J. Nucl. Med.
, vol.37
, pp. 2024-2029
-
-
Adam, L.-E.1
Bellemann, M.E.2
Brix, G.3
Lorenz, W.J.4
-
11
-
-
0032097403
-
A model of the high count rate performance of NaI(Tl)-based PET detectors
-
June
-
J. A. Wear, J. S. Karp, R. Freifelder, D. A. Mankoff, and G. Muehllehner, "A model of the high count rate performance of NaI(Tl)-based PET detectors," IEEE Trans. Nucl. Sci., vol. 45, pp. 1231-1237, June 1998.
-
(1998)
IEEE Trans. Nucl. Sci.
, vol.45
, pp. 1231-1237
-
-
Wear, J.A.1
Karp, J.S.2
Freifelder, R.3
Mankoff, D.A.4
Muehllehner, G.5
-
12
-
-
0003710963
-
-
Ph.D. dissertation, Univ. Pennsylvania, Philadelphia, PA
-
S. Surti, "A Model of Scintillation Detector Performance for Positron Emission Tomography," Ph.D. dissertation, Univ. Pennsylvania, Philadelphia, PA, 2000.
-
(2000)
A Model of Scintillation Detector Performance for Positron Emission Tomography
-
-
Surti, S.1
-
13
-
-
0024143307
-
An evaluation of a two-dimensional array detector for high-resolution PET
-
Dec.
-
M. Dahlbom and E. J. Hoffman, "An evaluation of a two-dimensional array detector for high-resolution PET," IEEE Trans. Med. Imaging, vol. 7, pp. 264-272, Dec. 1988.
-
(1988)
IEEE Trans. Med. Imaging
, vol.7
, pp. 264-272
-
-
Dahlbom, M.1
Hoffman, E.J.2
-
14
-
-
0034594169
-
Performance of a GSO brain PET camera
-
Nov.
-
J. S. Karp, S. Surti, R. Freifelder, M. E. Daube-Witherspoon, C. Cardi, L.-E. Adam, B. Chase, P. Vaska, and G. Muehllehner, "Performance of a GSO brain PET camera," IEEE MIC Conf. Rec., Nov. 2000.
-
(2000)
IEEE MIC Conf. Rec.
-
-
Karp, J.S.1
Surti, S.2
Freifelder, R.3
Daube-Witherspoon, M.E.4
Cardi, C.5
Adam, L.-E.6
Chase, B.7
Vaska, P.8
Muehllehner, G.9
-
15
-
-
0025414253
-
Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
-
Apr.
-
S. C. Strother, M. E. Casey, and E. J. Hoffmann, "Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts," IEEE Trans. Nucl. Sci., vol. 37, pp. 783-788, Apr. 1990.
-
(1990)
IEEE Trans. Nucl. Sci.
, vol.37
, pp. 783-788
-
-
Strother, S.C.1
Casey, M.E.2
Hoffmann, E.J.3
|