-
1
-
-
0026868258
-
First results on the hybrid photodiode tube
-
R. DeSalvo, W. Hao, K. You, Y. Wang, and C. Xu, "First results on the hybrid photodiode tube," Nucl. Instrum. Methods, vol. A315, pp. 375-384, 1992.
-
(1992)
Nucl. Instrum. Methods
, vol.A315
, pp. 375-384
-
-
DeSalvo, R.1
Hao, W.2
You, K.3
Wang, Y.4
Xu, C.5
-
2
-
-
0028202316
-
Photon counting with a hybrid photomultiplier tube (HPMT)
-
C. D'Ambrosio, T. Gys, H. Leutz, D. Piedigrossi, D. Puertolas, and S. Tailhardat, "Photon counting with a hybrid photomultiplier tube (HPMT)," Nucl. Instrum. Methods, vol A338, pp. 389-397, 1994.
-
(1994)
Nucl. Instrum. Methods
, vol.A338
, pp. 389-397
-
-
D'Ambrosio, C.1
Gys, T.2
Leutz, H.3
Piedigrossi, D.4
Puertolas, D.5
Tailhardat, S.6
-
3
-
-
0001746581
-
A new position sensitive photon detector based on an imaging silicon pixel array
-
T. Gys, C. D'Ambrosio, H. Leutz, D. Piedigrossi, and D. Puertolas, "A new position sensitive photon detector based on an imaging silicon pixel array," Nucl. Instrum. Methods, vol. A355, pp. 386-389, 1995.
-
(1995)
Nucl. Instrum. Methods
, vol.A355
, pp. 386-389
-
-
Gys, T.1
D'Ambrosio, C.2
Leutz, H.3
Piedigrossi, D.4
Puertolas, D.5
-
4
-
-
4243266624
-
First beam exposure with a scintillating fibre tracker read out by an ISPA-tube
-
C. D'Ambrosio, T. Gys, H. Leutz, D. Piedigrossi, and D. Puertolas, "First beam exposure with a scintillating fibre tracker read out by an ISPA-tube," Nucl. Instrum. Methods, vol. A359, pp. 618-621, 1995.
-
(1995)
Nucl. Instrum. Methods
, vol.A359
, pp. 618-621
-
-
D'Ambrosio, C.1
Gys, T.2
Leutz, H.3
Piedigrossi, D.4
Puertolas, D.5
-
5
-
-
0001083496
-
Position sensitive photon counting with an ISPA tube
-
June
-
C. D'Ambrosio, T. Gys, H. Leutz, D. Piedigrossi, D. Puertolas, and S. Tailhardat, "Position sensitive photon counting with an ISPA tube," IEEE Trans. Nucl. Sci., vol. 42, pp. 130-133, June 1995.
-
(1995)
IEEE Trans. Nucl. Sci.
, vol.42
, pp. 130-133
-
-
D'Ambrosio, C.1
Gys, T.2
Leutz, H.3
Piedigrossi, D.4
Puertolas, D.5
Tailhardat, S.6
-
6
-
-
0029545719
-
An ISPA camera for gamma rays
-
Dec.
-
D. Puertolas, D. Piedigrossi, R. Pani, H. Leutz, T. Gys, F. de Notaristefani, and C. D'Ambrosio, "An ISPA camera for gamma rays," IEEE Trans. Nucl. Sci., vol. 42, pp. 2221-2228, Dec. 1995.
-
(1995)
IEEE Trans. Nucl. Sci.
, vol.42
, pp. 2221-2228
-
-
Puertolas, D.1
Piedigrossi, D.2
Pani, R.3
Leutz, H.4
Gys, T.5
De Notaristefani, F.6
D'Ambrosio, C.7
-
7
-
-
0030258658
-
An ISPA camera for beta radiography
-
Oct.
-
D. Puertolas, D. Piedigrossi, H. Leutz, T. Gys, and C. D'Ambrosio, "An ISPA camera for beta radiography," IEEE Trans. Nucl. Sci., vol. 43, pp. 2477-2487, Oct. 1996.
-
(1996)
IEEE Trans. Nucl. Sci.
, vol.43
, pp. 2477-2487
-
-
Puertolas, D.1
Piedigrossi, D.2
Leutz, H.3
Gys, T.4
D'Ambrosio, C.5
-
8
-
-
0031259027
-
An ISPA camera for gamma rays with improved energy resolution
-
Oct.
-
D. Puertolas, D. Piedigrossi, H. Leutz, T. Gys, F. De Notaristefani, and C. D'Ambrosio, "An ISPA camera for gamma rays with improved energy resolution," IEEE Trans. Nucl. Sci., vol. 44, pp. 1747-1752, Oct. 1997.
-
(1997)
IEEE Trans. Nucl. Sci.
, vol.44
, pp. 1747-1752
-
-
Puertolas, D.1
Piedigrossi, D.2
Leutz, H.3
Gys, T.4
De Notaristefani, F.5
D'Ambrosio, C.6
-
9
-
-
0023308150
-
Performance of a scintillating fibre detector for the UA2 upgrade
-
R. E. Ansorge et al., "Performance of a scintillating fibre detector for the UA2 upgrade," Nucl. Instrum. Methods, vol. A265, pp. 33-49, 1988.
-
(1988)
Nucl. Instrum. Methods
, vol.A265
, pp. 33-49
-
-
Ansorge, R.E.1
-
10
-
-
0028417280
-
Performance and calibration of the chorus scintillaing fibre tracker and optoelectronic readout system
-
S. Aoki et al., "Performance and calibration of the chorus scintillaing fibre tracker and optoelectronic readout system," Nucl. Instrum. Methods, vol. A344, pp. 143-148, 1994.
-
(1994)
Nucl. Instrum. Methods
, vol.A344
, pp. 143-148
-
-
Aoki, S.1
-
11
-
-
0033898001
-
A multichannel single photon sensitive detector for high energy physics
-
L. Benussi et al., "A multichannel single photon sensitive detector for high energy physics," Nucl. Instrum. Methods, vol. A442, pp. 154-158, 2000.
-
(2000)
Nucl. Instrum. Methods
, vol.A442
, pp. 154-158
-
-
Benussi, L.1
-
12
-
-
36849139664
-
Scintillation camera
-
Jan.
-
H. O. Anger, "Scintillation camera," Rev. Sci. Instrum., vol. 29, pp. 27-33, Jan. 1958.
-
(1958)
Rev. Sci. Instrum.
, vol.29
, pp. 27-33
-
-
Anger, H.O.1
-
13
-
-
0000233531
-
Sensitivity, resolution and linearity of the scintillation camera
-
June
-
_, "Sensitivity, resolution and linearity of the scintillation camera," IEEE Trans. Nucl. Sci., vol. NS-13, pp. 380-392, June 1966.
-
(1966)
IEEE Trans. Nucl. Sci.
, vol.NS-13
, pp. 380-392
-
-
-
14
-
-
0000526344
-
Design of a mosaic BGO detector system for positron CT
-
Feb.
-
H. Uchida, T. Yamashita, M. Iida, and S. Muramatsu, "Design of a mosaic BGO detector system for positron CT," IEEE Trans. Nucl. Sci., vol. NS-33, pp. 464-467, Feb. 1986.
-
(1986)
IEEE Trans. Nucl. Sci.
, vol.NS-33
, pp. 464-467
-
-
Uchida, H.1
Yamashita, T.2
Iida, M.3
Muramatsu, S.4
-
15
-
-
0001284107
-
Position sensitive scintillation detector for gamma rays using a GSO crystal
-
Y. Nagai and T. Hyodo, "Position sensitive scintillation detector for gamma rays using a GSO crystal," Nucl. Instrum. Methods, vol. A349, pp. 285-288, 1994.
-
(1994)
Nucl. Instrum. Methods
, vol.A349
, pp. 285-288
-
-
Nagai, Y.1
Hyodo, T.2
-
16
-
-
0001628178
-
Position sensitive scintillation detector for hard X-rays
-
J. M. Poulsen, R. Verbeni, and F. Frontera, "Position sensitive scintillation detector for hard X-rays," Nucl. Instrum. Methods, vol. A310, pp. 398-402, 1991.
-
(1991)
Nucl. Instrum. Methods
, vol.A310
, pp. 398-402
-
-
Poulsen, J.M.1
Verbeni, R.2
Frontera, F.3
-
17
-
-
0028499294
-
Multi-crystal YAP:Ce detector system for position sensitive measurements
-
R. Pani et al., "Multi-crystal YAP:Ce detector system for position sensitive measurements," Nucl. Instrum. Methods, vol. A348, pp. 551-558, 1994.
-
(1994)
Nucl. Instrum. Methods
, vol.A348
, pp. 551-558
-
-
Pani, R.1
-
18
-
-
0027644234
-
Characterization of the response of a double side micro-strip silicon detector to X-rays in the diagnostic range
-
Aug.
-
A. Bandettini et al., "Characterization of the response of a double side micro-strip silicon detector to X-rays in the diagnostic range," IEEE Trans. Nucl. Sci., vol. 40, pp. 983-986, Aug. 1993.
-
(1993)
IEEE Trans. Nucl. Sci.
, vol.40
, pp. 983-986
-
-
Bandettini, A.1
-
19
-
-
0001162443
-
Silicon X-ray detector for sinchrotron radiation digital radiography
-
F. Arfelli et al., "Silicon X-ray detector for sinchrotron radiation digital radiography," Nucl. Instrum. Methods, vol. A353, pp. 366-370, 1994.
-
(1994)
Nucl. Instrum. Methods
, vol.A353
, pp. 366-370
-
-
Arfelli, F.1
-
20
-
-
0030166187
-
Digital mammography at the Trieste sinchrotron light source
-
June
-
_, "Digital mammography at the Trieste sinchrotron light source," IEEE Trans. Nucl. Sci., vol. 43, pp. 2061-2067, June 1996.
-
(1996)
IEEE Trans. Nucl. Sci.
, vol.43
, pp. 2061-2067
-
-
-
21
-
-
0033876534
-
X-ray detection with a scintillating YAP window hybrid photomultiplier tube
-
Feb.
-
C. D'Ambrosio, F. De Notaristefani, H. Leutz, D. Puertolas, and E. Rosso, "X-ray detection with a scintillating YAP window hybrid photomultiplier tube," IEEE Trans. Nucl. Sci., vol. 47, pp. 6-12, Feb. 2000.
-
(2000)
IEEE Trans. Nucl. Sci.
, vol.47
, pp. 6-12
-
-
D'Ambrosio, C.1
De Notaristefani, F.2
Leutz, H.3
Puertolas, D.4
Rosso, E.5
-
22
-
-
0026902977
-
A 1006 element hybrid silicon pixel detector with strobed bynary output
-
F. Anghinolfi et al., "A 1006 element hybrid silicon pixel detector with strobed bynary output," IEEE Trans. Nucl. Sci., vol. 39, pp. 654-661, 1992.
-
(1992)
IEEE Trans. Nucl. Sci.
, vol.39
, pp. 654-661
-
-
Anghinolfi, F.1
-
23
-
-
0034245141
-
Photoelectron backscattering from silicon anodes with hybrid photon detector tubes
-
Aug.
-
C. D'Ambrosio and H. Leutz, "Photoelectron backscattering from silicon anodes with hybrid photon detector tubes," IEEE Trans. Nucl. Sci., vol. 47, pp. 1685-1690, Aug. 2000.
-
(2000)
IEEE Trans. Nucl. Sci.
, vol.47
, pp. 1685-1690
-
-
D'Ambrosio, C.1
Leutz, H.2
-
24
-
-
0026653712
-
Spatial resolution and count density requirements in brain SPECT imaging
-
M. D. Madsen et al., "Spatial resolution and count density requirements in brain SPECT imaging," Phys. Med. Biol., vol. 37, pp. 1625-1631, 1992.
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1625-1631
-
-
Madsen, M.D.1
-
25
-
-
0034318458
-
Cristalline YAlO3 as a novel window for photodetectors
-
C. D'Ambrosio, F. De Notaristefani, H. Leutz, D. Puertolas, and E. Rosso, "Cristalline YAlO3 as a novel window for photodetectors," Nucl. Instrum. Methods, vol. A454, pp. 221-226, 2000.
-
(2000)
Nucl. Instrum. Methods
, vol.A454
, pp. 221-226
-
-
D'Ambrosio, C.1
De Notaristefani, F.2
Leutz, H.3
Puertolas, D.4
Rosso, E.5
|